Siemens Healthineers Academy

Cios Spin Live Graph Overlay Job Aid

This job aid explains how to use Live graph overlay. Live graph overlay allows you to draw and edit lines in an ongoing examination.

Live Graph Overlay Job Aid Cios Spin This document explains how to use Live graph overlay. Live graph overlay allows you to draw and edit lines in an ongoing examination. The lines can be transferred to the subsequent live images. Such graphic overlays are used, for example, in orthopedics, traumatology as well as in subtraction and roadmap examinations. For example, lines can be drawn into fill images to support the treatment of abdominal aortic aneurysms. LGO_Cios_Alpha LGO Cios Alpha Clos Spin 30x30 VA30 0067 17-04-2019 01-01-1932 01-01-1932 11:31:53 AM 000 Dotted Live Graph Overlay Line Orbital 0º Angular 0º < 0.1 mGy < 0.01 pGy*m2 00:00:00 hh:mm:ss Single Image Fluoro 976 1 976 OPAC 62.3 kV lisk#1 0.72 mA: LUT NAT 2 D: 0.015 LUT SUB 2 Service switch 53: ON Mag 0 Edge 0.70 C28: 2/2 C: 120 WW: 4095 Vase Standard B: 3000 WC: 1600 Live Graph Overlay Function Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 SIEMENS Master Template Effective Date: 10 Aug 2021 | HILS 2224 Job Aid Effective Date: 12 APR 2022 | HOOD05162003266099 Healthineers Job Aid | Live Graph Overlay Effective Date: 12 APR 2022 | HOOD05162003266099 How to Open the Live Graph Overlay Menu Follow these steps to open the Live graph overlay menu: 1. Display the required image. 2. Open the Processing task card. 3. Press the Live graph overlay button. The Live graph overlay menu is displayed. X 2D 3D Orb.0º Ang.0º Store O: 0º not flipped position 20 68 Set Delete point selected uGym2 kV 00:00:10 17 .......... hh:mm:ss mA End line * Collimator Laser Reset timer Edit line Delete all Series #: Image #: Fluoro Single 3D XYZ image Scan Rotate Live graph Zoom Pan Measure Flip overlay Shutter Annotate Reset all Sub Road DCM REF + Brightness Overview Hold Cine Contrast reference replay Previous Next Medium Auto Dose Metal A + B correction Tech lock Image Target Transfer Store cine Export to enhance Pointer Store Print USB Mag 15 p/s Magnify Motion Noise filter Pulse rate PREPARATION PROCESSING EXTERNAL Close pat. Keyboard Please note: It is not possible to create live graphic overlays on imported external images. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 2 of 7 Job Aid | Live Graph Overlay Effective Date: 12 APR 2022 | HOOD05162003266099 Drawing Lines Lines should be drawn as a polygon, where each change in direction creates a vertex in the image. Use the mouse to place the arrow at the desired starting point. 1. Press this button to set the starting point and vertices at the respective mouse Set pointer positions. Move the mouse to draw the line. poin 2. Press this button at the required end point. The new line is shown as a dotted line in the image. End line To draw additional lines, repeat the steps above. Please note: When the line is drawn and no radiation has been released, the line is dotted. LGO_Cios_Alpha LGO Cios Alpha Cios_Spin 30x30 VA30 0067 17-04-2019 01-01-1932 01-01-1932 11:31:53 AM 000 Dotted Line Orbital 0º Angular 0º < 0.1 mGy < 0.01 pGy*m2 00:00:00 hh:mm:ss Single Fluoro 976 1 976 OPAC 62.3 kV k#1 97ª 0.72 mA: LUT NAT 2 D: 0.015 LUT SUB 2 @Service switch 53: ON Mag 0 Edge 0,70 C28: 2/2 C: 120 WW: 4095 Vase Standard B: 3000 WC: 1600 SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 3 of 7 Job Aid | Live Graph Overlay Effective Date: 12 APR 2022 | HOOD05162003266099 When radiation is released, the dotted line is displayed as a solid line, and the line is embedded in the image. The old overlay is replaced by the newly drawn in lines in the following images. If you store images with the Live Graph Overlay function active, the Live Graph Overlay line will be burned into the image and cannot be deleted from the stored image anymore. Deleting Points If you have placed a point incorrectly, you can delete it immediately after you have drawn it as long as you have not set a new end point. ............ < Press this button to delete the last point from the image. Delete Press the button again to delete the previous point. You can continue drawing the line. selected Please note: If you delete a dotted line, then it is immediately deleted from the left monitor. If you delete a solid line, then it will not be deleted from the left monitor until you release radiation again. Postprocessing Lines Postprocessing via the Live graph overlay menu is only possible for newly drawn lines (dotted). You can postprocess a previously used overlay (solid lines) using the Measure Annotate menu Please refer to the Measurements and Annotations Job Aid for more information about this topic. To postprocess a newly drawn line, do the following: 1. Move the mouse pointer to the line or a point to select the given graphic object. 2. Press this button. Now, you can move the selected point or line with the .................. arrow buttons. Edit line ............ 3. To delete a selected point or the complete line, select the Delete selected Delete button. selected SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 4 of 7 Job Aid | Live Graph Overlay Effective Date: 12 APR 2022 | HOOD05162003266099 Deleting All Lines To delete all lines, press the Delete All button. The newly drawn graphic overlay (dotted lines) is deleted. 2D Orb.0º X 3D Ang.0º Store U: 0º not flipped position .......... % 20 68 Set Delete point selected uGym2 KV 00:00:10 17 ........ hh:mm:ss mA End line * ................... Collimator Laser Reset timer Edit line Delete all Series #: Image #: Fluoro Single 3D R RA XYZ image Scan Rotate Live graph Zoom Pan Measure Flip overlay Shutter Annotate Reset all Sub Road OCM REF + Brightness Contrast Overview Hold Cine reference replay Previous Next Medium Auto Dose Metal correction Tech lock A +B Image Target Export to enhance Pointer Transfer Store Store cine Print USB Mag 0 15 p/s Magnify Motion Noise filter Pulse rate PREPARATION PROCESSING EXTERNAL Close pat. Keyboard SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 5 of 7 Job Aid | Live Graph Overlay Effective Date: 12 APR 2022 | HOOD05162003266099 Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product-related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 6 of 7 Job Aid | Live Graph Overlay Effective Date: 12 APR 2022 | HOOD05162003266099 SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 7 of 7

  • ciosspin
  • c-arm
  • livegraph
  • graphoverlay
  • live
  • graph
  • overlay
  • live graph overlay
  • mobile c-arms
  • carm