Cios Select Multifunctional Wireless Foot Switch Job Aid
This job aid explains the functions of the multifunctional foot switch and how to secure it on your Cios Select.
Multifunctional Wireless Footswitch (Option) Job Aid Cios Select The optional multifunctional wireless foot switch offers the same functions as the standard foot switch, such as radiation release and image storage. Moreover, it provides additional features, such as a mode and save button. In this job aid, you will learn about the functions of the multifunctional wireless foot switch. Overview The following image shows the standard configuration of the multifunctional wireless foot switch. Please note that the layout and functionality assigned to the foot pedals can be configured in the service software, and therefore can deviate from the standard configuration. (1) (6) (2) (7) MODE (3) - (8) . MODE (4) (5) Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 SIEMENS Master Template Effective Date: 10 Aug 2021 | HILS 2224 Job Aid Effective Date: 17 Sep 2021 | HOOD05162003217977 Healthineers Job Aid | Multifunctional Wireless Foot Switch (Option) Effective Date: 17 Sep 2021 | HOOD05162003217977 No. Description No. Description 1 Stirrup 5 Right pedal Prevents unintended actuation. Radiation release for fluoroscopy (standard Use it to re-position the foot switch by foot. setting) 2 Connection status LED 6 Rotary knob of battery compartment 3 Battery status LED 7 Save button Stores images or scenes. 4 Left pedal 8 MODE button Radiation release for the selected operating Changes operating modes. mode States of the Status LED No. Subject Modes Battery status LED • Green: Battery full or nearly full 1 Battery capacity • Orange: Battery almost full The battery capacity is also shown on • Orange (flashing): Battery low the left monitor’s status bar. Connection status LED • Green: Connection active Radio link or pairing mode • Orange: No connection active • Orange (flashing): Foot switch not paired • Green and orange (alternately flashing): Pairing mode activated Battery status LED + • Orange (both LEDs flashing): Fatal Connection status LED system errors (for example, battery Fatal error or foot switch update exhausted or memory error) • Green and orange (both LEDs alternately flashing): Firmware update process running SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 2 of 8 Job Aid | Multifunctional Wireless Foot Switch (Option) Effective Date: 17 Sep 2021 | HOOD05162003217977 Switch on the Wireless Foot Switch Take the wireless multifunctional foot switch out of the foot switch holder on the monitor trolley. NCCE Place it horizontally on the floor. This will switch on the foot switch automatically. Swivel the stirrup into the upright position until it locks. The foot switch is now ready to use. The foot switch automatically switches to standby mode if it is not used for a certain period of time. Activate it again by pressing any button or pedal. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 3 of 8 Job Aid | Multifunctional Wireless Foot Switch (Option) Effective Date: 17 Sep 2021 | HOOD05162003217977 Select an Operating Mode If necessary, press the Mode button several times to select one of the operating modes: Single image, Fluoro, Sub, Road or a video source (depending on the available operating modes). MODE MODE The selected operating mode is indicated in the Examination task card and on the keyboard on the C-arm system. DOSE P/s KV mA .mAS min O A R Pls - + Rotate Left Rotate Right Pulse Rate Motion Dose Laser Tech Lock Reset Timer C 88 In Out Brightness Edge Enhan. Replay Fluoro Single Image N Application Application Rotate Left Rotate Right Contrast + Contrast Print/Export R Sub REFO Road B RA A B w Application Application Leaves In Leaves Out Flip Vertical Flip Horizont. Mag Hold Ref. Transfer Store A confirmation sound acknowledges successful operating mode/video source switchover. You can release radiation again right away. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 4 of 8 Job Aid | Multifunctional Wireless Foot Switch (Option) Effective Date: 17 Sep 2021 | HOOD05162003217977 Release radiation The functionality of the pedals can optionally be changed. The information provided in this document refers to the default settings. Use the right pedal to activate fluoroscopy. Keep the foot pedal pressed during radiation release. MODE . MODE Press the left pedal to activate the currently selected operating mode. Exception: If fluoroscopy mode is selected, the left pedal is assigned as Single Image operating mode. In this case, keep pressing the pedal until the radiation stops automatically. . MODE SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 5 of 8 Job Aid | Multifunctional Wireless Foot Switch (Option) Effective Date: 17 Sep 2021 | HOOD05162003217977 Store images Press the save button on the multifunctional foot switch. • Last image hold (LIH): Hold the key for less than two seconds to store the image last recorded. () MODE • Last scene hold (LSH): Hold the key for more than two seconds to store the scene last recorded. MODE The images are stored in the local database. They are transferred from the left monitor to the right monitor unless the Hold reference function is active. Replace the batteries 1. To open the battery compartment, lightly press in the knob and turn it counterclockwise. 2. Remove the batteries. 3. Insert new batteries (LR14/Type C) into the foot switch. 4. To close the battery compartment, insert the knob into the depressions. Press lightly and turn it until it clicks into place. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 6 of 8 Job Aid | Multifunctional Wireless Foot Switch (Option) Effective Date: 17 Sep 2021 | HOOD05162003217977 Secure the Foot Switch for Transport For secure storage and transportation of the foot switch, insert the foot switch into the holder on the left side of the monitor trolley. NCCE .n. Ensure that the colored symbols on the foot switch are lined up with the ones on the holder to avoid inserting the wrong foot switch. The following colored symbols are used for unique allocation of the foot switch to the holder: SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 7 of 8 Job Aid | Multifunctional Wireless Foot Switch (Option) Effective Date: 17 Sep 2021 | HOOD05162003217977 Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 8 of 8
- cois
- carm
- mobile c-arm
- image intensifier
- II
- I.I.