Siemens Healthineers Academy

Install Checklist Advanced

This checklist aids in the installation and initial set up of advanced features on the ACUSON Maple ultrasound system. 

ACUSON Maple Ultrasound System Installation Checklist Software Release 1.0 Advanced Applications siemens-healthineers.com/maple Healthineers This checklist represents features discussed during system training by the Clinical Sales Specialist. We recommend reading and reviewing all sections of the manual for further information and explanation of the system and its usage. ü eSieScan Workflow Protocols (Option) End the Protocol Customize and Create Protocols (Customize Export/Import Protocols Under Presets/eSieScan) ü Physio Module (Option) Customize Name, Progression and End Customize View Transducers/Exams Supported Customize Body Markers/Text Steerable CW Doppler/Auxiliary CW Doppler Customize Measurements ECG Setup and Use Select a Protocol – Touch Screen/Registration Auxiliary ECG Setup and Use Page Cardiac Specific Image Settings Add/Delete a View DTI Doppler Tissue Imaging Capability Pause, Skip and Resume Color DTI Capability/Doppler Tissue Energy (DTE) Begin an Additional Protocol SIEMENS Healthineers ACUSON Maple Ultrasound System Installation Checklist Software Release 1.0 Advanced Applications This checklist represents features discussed during system training by the Clinical Sales Specialist. We recommend reading and reviewing all sections of the manual for further information and explanation of the system and its usage. ü Anatomical M-mode (AMM) ü eSie OB Measurements (Option) Transducers and Exams Supported Available Measurements (BPD, HC, AC, FL, HL, OFD) Disable Bypass Cursor Under Presets/Display/ Doppler and M-mode/Bypass Cursor Mode Activate eSie OB/Reposition Measurement Markers Activate AMM (Angle/Marker) ü Stress Echo (Option) Position/Rotate M-mode Cursor and AMM Cursor Customize Stress Echo Under Presets/Stress Echo Exit AMM Access Stress Echo ü Cardiac Measurements, Calculations and Reports Stress Echo with LVO Contrast Cardiac Measurements and Report Customization Touch Screen – Activate Stress Echo 2D Measurements, Calculations and Labels Protocol Selection M-mode Measurements, Calculations and Labels Acquire/Select Views/Rename Views/Select Stages Doppler Measurements, Calculations and Labels Pause/Resume Protocol Cardiology Worksheets and Reports Review/Select Loops ü eSie Follicles (Option) Labels On/Off Activate eSie Follicles/Reposition Measurement Complete Acquisition Markers ü eSie Measure Workflow Acceleration Display/Compare Selected Loops Package (Option) Shuffle Mode Acquire/Select a Clip Exclude Frames From Review Activate/Deactivate eSie Measure Package Save Stress Echo Data Select the Measurement Group Wall Motion Scoring Perform an eSie Measure Measurement or Series Measure LV Volume Reposition a Marker Review/Edit/Store Stress Echo Reports Adding to the Report 2/6 siemens-healthineers.com/maple ACUSON Maple Ultrasound System Installation Checklist Software Release 1.0 Advanced Applications This checklist represents features discussed during system training by the Clinical Sales Specialist. We recommend reading and reviewing all sections of the manual for further information and explanation of the system and its usage. ü eSie Left Heart Measurements Package ü PISA AR/TR Package (Option) Compatible Clips (Process LV and LA, or LV only) Image Settings Tool Orientation Activate eSie Left Heart Package Calculation Parameters Specify View ü Transesophageal Echo (Option) Calculation Data View and Select Frames/Heart Cycles Exams Supported Adjust Border Outline 90 Degree Increments Knobology Review Manual Trace 5VT TEE Transducer Reposition Long Axis ü Contrast LVO (Option) Guided Trace/Manual Trace Save/Transfer Measurement Calculations to Transducers/Exams Supported Report Activating/Exiting LVO Contrast Exit eSie Left Heart Package Clip Settings ü syngo VVI™ Cardiac Strain (Option) Timer – Single/Dual Compatible Clips Imaging Options: Activating and Exiting Burst Adjust Contours Burst Time Delete Analysis/Reselect View/Recalculate Analysis Display Options/Save Results 3/6 siemens-healthineers.com/maple ACUSON Maple Ultrasound System Installation Checklist Software Release 1.0 Advanced Applications This checklist represents features discussed during system training by the Clinical Sales Specialist. We recommend reading and reviewing all sections of the manual for further information and explanation of the system and its usage. ü Contrast – Abdominal (Option) Quality Factor (Low/Med/High) Transducers/Exams Supported Angle/Quality Activating/Exiting Contrast Renders (Surface/MaxIP/MeanIP/MinIP) Touch Screen Options: LightSource/Lighting/Light Percentage Agent Curved VOI Display options ü 3D/4D Frozen/4D Live (Option) Clip Settings VOI/Cine/Margins Timer – Single/Dual Renders (Surface/MaxIP/MeanIP/MinIP) Split Mode LightSource/Lighting/Light Percentage Biopsy – Center Line/Ruler/Grid Reset Curve Imaging Options: Reset (All/Curve/Orientation) Flash Sequence Quadrant Selection (A/B/C/D) Configure Flash Sequence Flip Burst Sync Peak Hold Layout (4:1/2:1/3:1/1:1) Burst Time VR Rotation (0/90/180/270) ü 3D/4D (Option) Threshold/Opacity/Smooth Transducer/Exam Types Brightness/Contrast/Tint Activating 3D Render Directions (Up/Down/Front/Back/Left/ Right, etc.) 4/6 siemens-healthineers.com/maple ACUSON Maple Ultrasound System Installation Checklist Software Release 1.0 Advanced Applications This checklist represents features discussed during system training by the Clinical Sales Specialist. We recommend reading and reviewing all sections of the manual for further information and explanation of the system and its usage. ü Edit Tab – 3D/4D Frozen/4D Live – ü Volume/Image Storage and Export Functions Touch Screen (Option) (Option) Undo All Edit/Undo Last Edit Clip/Image Polygon/Trace/Large Eraser/Small Eraser Export Destinations (PACS/USB) ü Multislice Edit Tab – 3D/4D Frozen – Export Options (PC or DICOM) Touch Screen (Option) Quadrants (A/B/C) Layout/Slices/Distance/Position of Slices Center Slice Icon I acknowledge that I have received training on items checked above on the ACUSON Maple ultrasound system, Software Release 1.0 and had the opportunity to ask questions. Facility: Date(s) of Training: Customer Name: Signature: Clinical Specialist Name: Signature: 5/6 siemens-healthineers.com/maple ACUSON Maple, DTI Doppler tissue imaging capability, At Siemens Healthineers, we pioneer breakthroughs in eSie Left Heart measurement package and eSieScan healthcare. For everyone. Everywhere. By constantly workflow protocols are trademarks of Siemens Medical bringing breakthrough innovations to market, we enable Solutions USA, Inc. healthcare professionals to deliver high-quality care, leading to the best possible outcome for patients. syngo® Velocity Vector Imaging technology is a registered trademark of Siemens Healthcare GmbH Our portfolio, spanning from in-vitro and in-vivo diagnostics to image-guided therapy and innovative cancer care, is crucial for clinical decision-making and treatment pathways. With our strengths in patient twinning, precision therapy, as well as digital, data, and artificial intelligence (AI), we are well positioned to take on the biggest challenges in healthcare. We will continue to build on these strengths to help fight the world’s most threatening diseases, improving the quality of outcomes, and enabling access to care. We are a team of 66,000 highly dedicated employees across more than 70 countries passionately pushing the boundaries of what’s possible in healthcare to help improve people’s lives around the world. Siemens Healthineers Headquarters Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemensstr. 3 Ultrasound 91301 Forchheim, Germany 22010 S.E. 51st Street Phone: +49 9191 18-0 Issaquah, WA 98029, USA siemens-healthineers.com Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · QR700002313 · 14481 1123 online · ©Siemens Medical Solutions USA, Inc., 2023

  • ACUSON
  • Maple
  • NX Family
  • Sales
  • Training
  • Ultrasound
  • Doppler
  • Multispecialty
  • General Imaging
  • Cardiac
  • Vascular
  • OB
  • Obstetrics
  • Gynecology
  • 4D
  • 3D
  • 2D
  • Radiology
  • Cardiology
  • Echocardiography
  • TEE