BLADE & SMS BLADE
This JobAid gives you an introduction and development of the BLADE and SMS-BLADE sequence for non-diffusion imaging. We recommend that you know your software version (e.g. XA31A, XA70A) of your product in order to identify the suitable content from this JobAid.
Please note: For more information about BLADE Diffusion there is a separate JobAid.
Target group: All users
Recommended to be viewed on the following devices: All (incl. tablet, smartphone).
SIEMENS Healthineers syngo BLADE & SMS BLADE Job Aid For non-diffusion imaging Template Effective Date: 10 Aug 2021 | HILS 2223 Job Aid Effective Date: 20 Sep 2024 | QR700013568 Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo BLADE & SMS BLADE SIEMENS Healthineers Table of contents What is BLADE? 3 Software development overview 4 TSE sequence ≤ XA50A 5 Fast TSE sequence ≤ XA50A 6 TSE vs. Fast TSE ≤ XA50A 7 BLADE sequence > XA50A 8 BLADE vs. BLADE Diffusion > XA50A 9 Fast BLADE vs. Fast Mode > XA50A 10 SAR handling 11 Simultaneous Multi‐Slice (SMS) 13 SMS BLADE parameter settings > XA70A 14 2 Job Aid Effective Date: 20 Sep 2024 | QR700013568 You need to know the software version (e.g., XA31, XA70) of your product to identify the suitable content. Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo BLADE & SMS BLADE SIEMENS Healthineers What is BLADE? syngo BLADE reduces the motion sensitivity of MR examinations. It’s a technique that incorporates a radial k-space trajectory in the images for all slice orientations. Key benefits: • Improves image quality by reducing motion effects during an MR sequence. This helps to visualize small lesions in non- cooperative patients (e.g., pediatric*, critical, elderly) • Allows scanning under suboptimal conditions due to involuntary motion like pulsation, respiration, etc. • Applicable in all body regions like head, spine, liver, knee Conventional BLADE 3 * The safety of imaging fetuses and infants under two years of age hasn’t been established. You have to decide about the Job Aid Effective Date: 20 Sep 2024 | QR700013568 benefit of the MRI examination compared to other imaging procedures. Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo BLADE & SMS BLADE SIEMENS Healthineers Software development overview Software version Before XA50A XA50A XA51A XA60A XA61A XA70A and after BLADE For T2-weighted, T1- As an option in a TSE sequence. As a dedicated BLADE sequence. Select BLADE in Resolution > Common > Verify that the Diffusion Mode under Diff is set to None by default. weighted, STIR, and Trajectory. Please note: The TSE sequence is only available for cartesian imaging and no longer for BLADE. DarkFluid imaging. As a dedicated fast_tse sequence. Fast BLADE Select BLADE in Resolution > Common > As an option in BLADE sequence. For faster, sharper and Trajectory. Click on the checkbox Fast Mode in Sequence > Part 2. streak free BLADE Fast BLADE Please note: Renaming from Fast BLADE (XA50A) to Fast Mode (from XA51A). imaging. checkbox available The fast_tse sequence is no longer available. in BLADE sequence. BLADE Diffusion For distortion free As a dedicated BLADE sequence. diffusion weighted Select 3-scan trace or 4-scan trace in Diff > Diffusion Mode. imaging. SMS BLADE & TSE reference scan Available for BLADE Diffusion only. Available also for For accelerated Select SMS in Resolution > Acceleration > Acceleration Mode. general BLADE. acquisitions. 4 Job Aid Effective Date: 20 Sep 2024 | QR700013568 Please check the availability of features according to your system type and your licenses. Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo BLADE & SMS BLADE SIEMENS Healthineers TSE sequence ≤ XA50A BLADE is based on a Turbo Spin Echo (TSE) sequence. SIEMENS > head >> library >> BLADE > t2_blade_tra_p2 ? X General ¿ 2:14 min 4Auto @ 2 0.7x0.7x4.0 mm3 @ 1.00 Each echo train of the sequence generates a low-resolution image Protocol Parameters Routine Contrast Resolution Geometry System Physio Inline Sequence Voice Commands with a phase-encoding direction rotated from one excitation to Execution Common Acceleration Filter the next. Image Management FoV Read 220 - mm Trajectory BLADE Auto Load FoV Phase 100.0 ¢ % BLADE Coverage 91.7 % Subsequently, the individual, low-resolution images are combined Copy References Slice Thickness 4.0 mm into a high-resolution image. Base Resolution 320 ¢ To activate BLADE, select BLADE in Resolution > Common > Trajectory. Interpolation] BLADE supports T2-weighted, T1-weighted, STIR, and DarkFluid pulse contrasts. OK Cancel 5 Job Aid Effective Date: 20 Sep 2024 | QR700013568 Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo BLADE & SMS BLADE SIEMENS Healthineers Fast TSE sequence ≤ XA50A The fast Turbo Spin Echo sequence (fast_tse) is a completely redesigned DEFAULT DEFAULT >> Sequence Region > Siemens Sequences >> Default ep_seg_phs 00:25 pulse sequence for faster, sharper, and streak free BLADE imaging, especially Q fast_tse ep_seg se 00:03 in the abdomen. Sequence Region [1] Siemens Sequences [1] ep_seg_therm 00:25 Default [1] The additional advantages of syngo BLADE fast_TSE are the reduction of T2 › Customer Sequences FastView 00:11 Service Sequences fast tse 01:53 decay effects from the neighboring k-space lines. Default fid 00:03 This results in broader blades. However, it will increase the coverage in k- f13d ce 00:08 space providing less blur and reducing the STAR like artifacts. f13d_rd 1:08:20 f13d_vibe 01:07 Please note: The fast_tse sequence is not available for QuietX, WARP, 3D, or fl pc 00:40 reduced EC sensitivity techniques. In addition, the fast_tse sequence is no fl_peri_tof 00:27 longer available since syngo XA51A and has been replaced by Fast BLADE/ Fast Mode (see p. 11). TSE Acquisition Pattern Fast_TSE Acquisition Pattern 6 Job Aid Effective Date: 20 Sep 2024 | QR700013568 Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo BLADE & SMS BLADE SIEMENS Healthineers TSE vs. Fast TSE ≤ XA50A The syngo BLADE FAST Turbo Spin Echo sequence parameters are located on the Sequence > Part 1 parameter card. Note the reduction in the time and the echo spacing on the syngo BLADE Fast TSE compared to the conventional BLADE sequence. SIEMENS > abdomen >> library >> BLADE > t2_blade_fs_tra_p3_trig_320 ? X SIEMENS >> abdomen >> library >> BLADE >> t2_fblade_fs_tra_p3_trig_320 ? General 0 2:10 min 1 Auto @ 3 1.2x1.2x6.0 mm3 ~ 1.00 General @ 1:55 min Auto 0 3 1.2x1.2x6.0 mm3 1.00 Protocol Parameters Routine Contrast Resolution Geometry S Total Measurement Time: 2:10 min Sequence Protocol Parameters Routine Contrast Resolution Geometry Total Measurement Time: 1:55 min Sequence Voice Commands Acquisition Duration: 1505 ms Voice Commands Acquisition Duration: 1363 ms Part 1 Part 2 Assistant Respiratory Cycles: 5+54 Execution Part 1 art 2 Assistant Execution Respiratory Cycles: 5+42 Image Management Sequence Name tseB Bandwidth 651 - Hz/Px Image Management Sequence Name ftseB Bandwidth 781 - Hz/Px Auto Load Dimension 2D Echo Spacing 5.10 ms Auto Load Echo Spacing 3.62 ms Copy References Copy References RF Pulse Type Fast Define Turbo Factor RF Pulse Type Fast Define Turbo Factor Turbo Factor 41 Turbo Factor 51 + Gradient Mode Fast Echo Trains per Slice 8 Gradient Mode Fast Echo Trains per Slice 6 4 Flow Compensation None Flow Compensation None OK Cancel OK Cancel syngo XA30A; BLADE - Conventional syngo XA30A; BLADE with fast_tse 7 Job Aid Effective Date: 20 Sep 2024 | QR700013568 Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo BLADE & SMS BLADE SIEMENS Healthineers BLADE sequence > XA50A SIEMENS The protocols for syngo BLADE are located in different SIEMENS SIEMENS > abdomen > library >> BLADE Q BLADE X regions of the body (e.g., head, c-spine, abdomen, etc.). multi-breath-hold Q BLADE X c-spine [1] t2_blade_fs_tra_p2_mbh_insp 01:50 t-spine [] abdomen [16] > I-spine As an example, you can find the different sequences in the Abdomen Assist [3] t2 blade_cor_p3_320_mbh_insp 01:42 whole-spine Dot Cockpit > SIEMENS > abdomen > library > BLADE. Angio Assist >[neck soft tissue [3] E Test Bolus t2_blade_fs_cor_p2_288_mbh 01:48 thorax [16] E Care Bolus heart t2_blade_stir_cor_p3_mbh_insp 01:49 quick protocols [ breast [1] abdomen [16] clinical libraries PACE free breathing pelvis female [3] library [13] E localizer t2_blade_fs_tra_p3_320_trig 03:23 > [ pelvis male tmj t2_fblade_fs_tra_p3_320_trig 03:18 shoulder [12] E T2 elbow [5] E 3D t2_blade_fs_cor_p3_320_trig 02:54 wrist [7] E diffusion hand E BLADE [13] t2_blade_fs_tra_p3_s2_320_trig 03:06 Ship [12] E dynamic > [ knee [12] BM Resp Sensor E Mapit ankle [6] E LiverLab t2_blade_fs_tra_p3_320_trigRESP 02:00 foot E Elastography lower extremity t2 blade fs cor_p3_320_trigRESP 01:41 > [ whole-body oncology library Deep Resolve > whole-body diffusion library Assist peripheral angiography library angiography spectroscopy library angiography ce intervention > [ pelvis female [3] 8 Job Aid Effective Date: 20 Sep 2024 | QR700013568 Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo BLADE & SMS BLADE SIEMENS Healthineers BLADE vs. BLADE Diffusion > XA50A Get more info on Training material a topic: available syngo BLADE for non-diffusion sequences was only SIEMENS » abdomen >> library >> BLADE >> t2_blade_fs_tra_p3_320_trig ? X available as an option in a TSE sequence until syngo MR General @ 2:00 min Auto 23 1.2x1.2x6.0 mm3 ? 1.00 XA50A. Since syngo XA51A you can use it as a dedicated Protocol Parameters Routine Contrast Resolution Geometry System Physio Diff Inline Sequence Voice Commands BLADE sequence. Execution Diffusion Mode None Diff. Weighted Images[] Image Management Trace Weighted Images Auto Load Please check that the settings under the SIEMENS library Copy References Tensor FA Maps (e.g. abdomen in the XA70A) and Protocol Parameters > myExam Analyzer ADC Maps Diff > Diffusion Mode are set to None by default. Exponential ADC Maps [] Please note: From syngo XA50A onwards BLADE Diffusion has been added in the SIEMENS library (e.g., head) and could also be selected. Invert Gray Scale Calculated b-value OK Cancel syngo MR XA70A 9 Job Aid Effective Date: 20 Sep 2024 | QR700013568 Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo BLADE & SMS BLADE SIEMENS Healthineers Fast BLADE vs. Fast Mode > XA50A Instead of using the separate sequence fast_tse, you can activate Fast BLADE on syngo MR XA50A and Fast Mode since syngo MR XA51A, under Protocol Parameter > Sequence > Part 2. By activating Fast BLADE/ Fast Mode, you can achieve shorter echo spacing and a higher SNR. Please note: The Scan Assist gives you information about the consequences of switching on Fast BLADE/ Fast Mode. If you select OK, it automatically adjusts the respective parameters. SIEMENS >> head >> library >> diffusion >> blade_diff_tra_160_p252_4mm ? SIEMENS >> abdomen >> library >> BLADE > t2_blade_fs_tra_p3_320_trig ? General 3:12 min Auto @ 4 @ 1.4x1.4x4.0 mm3 1.00 Genera @ 2:00 min Auto@ 3 1.2x1.2x6.0 mm3 1.00 Protocol Parameters Routine Contrast Resolution Geometry System Physio Diff Inline Sequence Protocol Parameters Voice Commands Routine Contrast Resolution Geometry System Physio Diff Inline Sequence Execution Part 1 Part 2 Assistant Voice Commands Execution Part 1 Part 2 Assistant Image Management Introduction Image Management Introduction v Auto Load Auto Load Copy References Copy References myExam Analyzer Acoustic noise reduction Off Acoustic Noise Reduction Off Hyperecho Fast BLADE Motion Correction Off Fast Mode Motion Correction Off OK Cancel OK Cancel syngo MR XA50A syngo MR > XA51A 10 Job Aid Effective Date: 20 Sep 2024 | QR700013568 Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo BLADE & SMS BLADE SIEMENS Healthineers SAR handling (1/2) syngo BLADE is sometimes limited by SAR restrictions due to a faster acquisition. The probability of SAR issues is higher when using fast_tse, Fast BLADE, or Fast Mode. Please note: If none of these options help, use the conventional BLADE sequence. SIEMENS > abdomen >> library > BLADE > t2_fblade_fs_tra_p3_trig ? SIEMENS >> abdomen > library >> BLADE > t2_fblade_fs_tra_p3_trig ? X General @ 1:50 min 4 Auto 0 3 @ 1.5x1.5x6.0 mm 1.01 General @ 1:50 min 4 Auto 03 @ 1.5x1.5x6.0 mm3 1.01 Protocol Parameters Routine Contrast Resolution Geometry System Physio Inline Sequence Protocol Parameters Routine Contrast Resolution Geometry System Physic Inline Sequence Voice Commands Voice Commands Common AutoAlign Navigator Saturation Tim Planning Suite Execution Part 1 Part 2 Assistant Execution Image Management Image Management Sequence Name ftseB Bandwidth 781 4 Hz/Px Auto Load Saturation Region Special Saturation None Auto Load Echo Spacing 3.64 ms Copy References Parallel H Copy References Parallel F Parallel F/H None RF Pulse Type Fast Define Turbo Factor Fast Turbo Factor 51 + Echo Trains per Slice 5 Flow Compensation None OK Cance OK Cance Change the setting in Geometry > Saturation > Special Saturation Change the setting in Sequence > Part 1 > RF Pulse Type to Normal. to None. 11 Job Aid Effective Date: 20 Sep 2024 | QR700013568 Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo BLADE & SMS BLADE SIEMENS Healthineers SAR handling (2/2) syngo BLADE is sometimes limited by SAR restrictions due to a faster acquisition. The probability of SAR issues is higher when using fast_tse, Fast BLADE, or Fast Mode. Please note: If none of these options help, use the conventional BLADE sequence. SIEMENS >> abdomen >> library >> BLADE >> t2_fblade_fs_tra_p3_trig ? X General & 3:30 min 4 Auto @ 3 @ 1.5x1.5x6.0 mm3 1.01 Protocol Parameters Routine Contrast Resolution Geometry System Physio Inline Sequence Voice Commands Execution Common Dynamic Fat Suppression Optimization X Image Management TR 3000.0 ms Fat-Water Contrast SPAIR ... Auto Load TE 95.00 ms Fat Saturation Strong Region Default Copy References TD 0.00 - ms Default Abdomen & Pelvis MTC Dark Blood Breast Thorax Magn. Preparation None Contrasts Wrap-up Magn. None Flip Angle 140 + deg Reconstruction Magnitude Close Set the Region to Default in the OK Cancel pop-up Fat Suppression Optimization. To change the SPAIR setting click in Contrast > Common > Fat-Water Contrast on … 12 Job Aid Effective Date: 20 Sep 2024 | QR700013568 Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo BLADE & SMS BLADE SIEMENS Healthineers Simultaneous Multi‐Slice (SMS) Simultaneous Multi‐Slice (SMS) acquires multiple slices simultaneously to reduce the measurement time (and TR) with no SNR loss from sub-sampling. The separation of slices is achieved by using different coil sensitivities along the slice direction (as with PAT). To improve the g-factor, use the blipped CAIPIRINHA. Please note: SMS is supported by BLADE Diffusion since > XA50A and for non-diffusion imaging since > XA70A. Key benefits: • More slices • Increase the number of slices with the same scan time using the same TR compared to a standard sequence • Reduced acquisition time • TR decreases or Turbo Factor increases when using the given number of slices compared to a standard sequence 13 Job Aid Effective Date: 20 Sep 2024 | QR700013568 Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 syngo BLADE & SMS BLADE SIEMENS Healthineers SMS BLADE parameter settings > XA70A To activate SMS for non-diffusion imaging from syngo MR XA70A upwards, select SMS in Resolution > Acceleration > Acceleration mode. In addition, the standard FOV Shift Factor of 4 is recommended. Please note: SMS is not compatible with Fast Mode. Check the settings for Fast Mode in Sequence > Part 2 or accept the suggestions of the Scan Assistant by selecting OK. SIEMENS >> abdomen >> library >> BLADE >> t2_blade_fs_tra_p4_52_320_trig ? X General 8 1:40 min Auto @ 8 1.2x1.2x6.0 mm3 1.00 Scan Assistant ? × Protocol Parameters Routine Contrast Resolution Geometry System Physio Diff nline Sequence Voice Commands Execution Common Acceleration Filter ? Your last change Image Management Acceleration Mode SMS Auto Load Fast Mode Off On Copy References will adapt the following parameters: myExam Analyzer Reference Scans TSE/Sep ... TE 100.00 84.00 ms SMS Factor 2 1 Acceleration Factor PE 4 FOV Shift Factor 4 1 Reference Lines PE 64 SMS Factor 2 - Ramp Sampling OK Undo FOV Shift Factor OK Cancel 14 Job Aid Effective Date: 20 Sep 2024 | QR700013568 Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Healthineers Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com 15 Job Aid Effective Date: 20 Sep 2024 | QR700013568 Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024
- BLADE
- blade
- sms
- SMS
- mr
- imaging
- XA70A