Siemens Healthineers Academy

Biograph Trinion Introduction to Exam Designer

This job aid will provide an introduction to the Exam Designer on the Biograph Trinion.

Introduction to Exam Designer Biograph Trinion VK10 If you have the appropriate user rights, you can view and/or modify Scan Protocols, Contrast Pro- tocols, and Clinical Decision Trees (CDT) parameters. To do so: 1. Open the Exam Designer. 2. Click the Settings icon. 3. Select Exam Designer from the settings menu. Please note: Only users logged in as Clinical Admin can access the Exam Designer, otherwise the entry is grayed out. ? Configuration Panel Administration Portal Administration Portal [EN] Clinical Configuration Checkup Daily QA Calibration er Resume syngo Remote Assist Screen recorder SaveLog Remote Service Exam Designer Create Screenshot Fast Contact File Browser Load Service Pack Direct Laser Check myNeedle Laser Check What is New Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 21 Apr 2023 | HILS 2224 Job Aid Effective Date: 29 May 2025 | QR700022221 Healthineers Job Aid | Introduction to Exam Designer Effective Date: 29 May 2025 | QR700022221 Here you find: Scan Protocols – Updating scan protocols • Contrast Protocols – Option with CARE Contrast • Examination Configuration – Patient characteristics along with decision trees • myExam Cockpit – Central engine of myExam Compass. Known as the “expert mode” for • the creation, customization, and configuration of Scan Strategies and Clinical Decision Trees (CDT). SIEMENS Healthineers Exam Designer Exam Designer Scan Protocols Examination Configuration myExam Cockpit Scan Protocols workspace ✓ The Scan Protocols workspace is the expert tool for creating, changing, and managing protocols, especially multiple protocols. ✓ In the Scan Protocols workspace, you can manage the pool of protocols and the underly- ing parameter settings which are available on the Protocol Selection tab. ✓ Customized protocols can be exported for either Archiving (e.g., back-up) or Viewing (e.g., print for audit). SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 2 of 7 Job Aid | Introduction to Exam Designer Effective Date: 29 May 2025 | QR700022221 Healthineers O Exam Designer ? & # Back to Exarn Designer Scan Protocols 1. Select Protocols . Modify Protocols 3. Confirm Changes Search Protocols: Enter protocol name or description. Q Filter by: Patient Type al Decision Tree all Show: Factory Protocols (108) Customer Protocols (12) Modality all syngo.via all Adult Child Head (0) Upper Extremities (0) Head (0) Upper Extremities (0) Add fold Add folder Neck (0) Lower Extremities (0) Neck (0) Lower Extremities (0) Trauma Trauma Shoulder (0) Vascular Head (0) Shoulder (0) Vascular Head (0) RTP RTP Thorax (0) Vascular Neck (0) Thorax (0) Vascular Neck (0) Specials Specials Abdomen (0) Vascular Thorax (0) Abdomen (0) Vascular Thorax (0) ntervention Baby PET Pelvis (0) Vascular Cardiac (0) Pelvis (0) Vascular Cardiac (O) Spine (0 Vascular Abdomen (0) Spine (0) Vascular Abdomen (0) Reset Selection Hide Delete Export Import Modify Protocols Please note: Decision Trees are available only for CT in VK10. SIEMENS Healthineers O. Exam Designer Back to Exam Designer myExam Cockpit 1. Select Decision Trees 2. Modify Decision Trees 3. Confirm Decision Trees Search Decision Trees: Enter name or description Q Filter By: Type Show: Factory Trees (36) Customer Trees (0) Select all Add folder Head (3) Thorax (8) Abdomen (4) Spine (4) Brain contrast medium necessary [[ ... Thorax multi [factory] Abdomen FoV [factory] C-Spine disc or bone [factory] Sinus sinusitis or soft tissue [factory] Thorax breathhold and X-CARE [fact ... Abdomen contrast medium necessd ... T- and L-Spine disc or bone [factory] Vascular Cardiac RTP Brain [factory] Thorax FoV [factory] Kidney TwinSpiral DE possible [facto ... Spine TwinSpiral DE possible [factory] Thorax contrast medium necessary [ ... Whole Body soft tissue or bone [fact ... Spine TwinSpiral metal DE possible [ ... General Neck (2) Thorax and Abdomen FoV [factory] Templates Neck FoV [factory] Thorax and Abdomen contrast medi ... Pelvis (3) Upper Extremities (0) Lung screening [factory] Unsorted Decision Trees Neck contrast medium necessary [fa .. Lung Low Dose breathhold and X C ... Pelvis soft tissue or bone [factory] Pelvis contrast medium necessary [f ... Lower Extremities (0) Shoulder (0) Pelvis TwinSpiral DE possibile [factory] Information Reset Selection Delete Export for Viewing Modify Tree 0 EN SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 3 of 7 Job Aid | Introduction to Exam Designer Effective Date: 29 May 2025 | QR700022221 Scan Protocols: Modify Protocol(s) – Allows user to modify any scan and recon parameter all in one place. SIEMENS Healthineers Exam Designer Back to Exam Designer Scan Protocols 1. Select Protocols 7. Modify Protocols 3. Confirm Changes Protocol Scan Favorites General Scan Dose Timing Config Physio Sca Contrast Recon Favorites General Recon Recon&GO Image Impression Recon Box Physio Recon Auto Tasking Inline Options Find/Replace Scan/Recon R. Scan Favorites Scan Recon Scan Mode Decision Trees CARE Dose4D & CARE KV CARE KV ICQ level CARE KV optimized for CIDIVal [mGy] Pitch it. Time| Absolu Select Protocols Valldate Scan Mode Confirm Changes COGDO EN Scan Protocols: Confirm Changes – This shows any modification (old vs. new) and allows final save. SIEMENS .... Exam Designer Healthineers O Back to Exam Designer Scan Protocols 1. Select Protocols 2. Modify Protocols 3. Confirm Changes Save Name Old Value New Value Modify Protocols Valldate Strategy Valldate Scan Mode Save Protocols EN SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 4 of 7 Job Aid | Introduction to Exam Designer Effective Date: 29 May 2025 | QR700022221 Export for Archiving ✓ Creates a back-up of all customer protocols with all parameters (including contrast proto- cols and decision trees that may be attached to the protocol). ✓ This back-up (zip file) can be reimported in case there is an issue with the system and all protocols are lost. ✓ The user has the ability to create a backup any time they update their protocols. File Browser x H:\SiteData\UserData\ProtocolManagement)ExportedScanProtocols Download Name Size Date ExportImages Protocols_ExportedForArchiving_2024.1.21.18.3.37.zip 69.83 KB 1/21/202. ExportRawData OnlineHelpContent teamplay UserData ProtocolManagement ExportedScanProtocols For Archiving ScanProtocolListing ScanProtocolsForImport For Viewing Referencelmages RespiratoryImport ScreenShot Export Import Save As 1 > This PC > TempFiles (I:) > ProtocolManagement > ExportedScanProtocols v 8 Search ExportedScanProtocols Organize New folder BEE V Downloads Name Date modified Type Size Music No items match your search. Pictures Videos SmartSimulator (B:) DB_Data (D:) Image_Data (E:) Local Disk (F:) Temporary Storage (G:) TempFiles (H:) TempFiles (I:) ProtocolManagement ExportedScanProtocols File name: |Protocols_ExportedForArchiving_2024.1.21.18.3.37 Save as type: |zip files Hide Folders Save Cancel SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 5 of 7 Job Aid | Introduction to Exam Designer Effective Date: 29 May 2025 | QR700022221 Export for Viewing ✓ All parameters (including recon parameters) of all selected protocols are always exported for viewing. ✓ You need ALL files exported for Viewing in order to open as XML for viewing. Totocol Name Factory Protocols Head Brain (factory] (Adult) ogogram canplanning Toperdition Scanplanning ToparautSin Teeogram 0 80 1120 580 Indications: stroke, hemorrhage, cerebral atrophy, hydrocephalus, inflammation, wo CM Routine SpiralAdultHead Scan modes: RoutineSpiralAdutHead SipiraïAduitHea@h-lighees: contrast Brain contrast -Decision Tree: Brain contrast medium Routine Spira AduitHea @care: medum medium necessary necessary [factory] Rou SequenceAdultlead necessary factory] wo CM Routine SequenceAdultleadinghres For Archiving For Viewing Brain Multi Phase Adult)" Export Import File Browser × H:\SiteData\UserData\ProtocolManagementScanProtocolListing\Protocols_ExportedForViewing_2024_01_21_18_06_54 SiteData Name Size Date 3DCam E DisplayStyle.css 3.83 KB 6/18/2021 Download Ex DisplayStyle.xslt 9.41 KB 6/18/2021 ExportImages E Protocols.xls 50.50 KB 1/21/202 E Protocols.xml ExportRawData 361.56 KB 1/21/202 E readme.txt 446 B 1/21/202. OnlineHelpContent teamplay UserData ProtocolManagement ExportedScanProtocols ScanProtocolListing > M Protocols ExportedFor SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 6 of 7 Job Aid | Introduction to Exam Designer Effective Date: 29 May 2025 | QR700022221 Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or In- structions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Opera- tor Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety infor- mation like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functional- ity”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fic- tional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers HQ I Siemens Healthi- neers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2024 Master Template Effective Date 21 Apr 2023 | HILS 2224 Healthineers Page 7 of 7

  • trinion
  • vk10
  • exam designer