Siemens Healthineers Academy
Automatic Software Update activation

Automatic Software Update activation

In this video, users will learn how to activate a new version of their syngo.via solutions software using the Automatic Software Update feature. The video covers how to receive update notifications, schedule or immediately activate updates, and verify successful installation, ensuring users can manage software upgrades independently and efficiently.

Target group: All users
Audio: Yes
Recommended to be viewed on the following devices: Laptop, desktop computer (sufficiently large display required)

This video shows you step by step how to perform the activation of a new version of your single via solutions. The new automatic software update feature lets you manage when. And how to activate? The new version completely on your own. In this video you will see. How end users are notified when a new version is available? How to activate the new version? How to check if the activation was successful please? Note all the information in this video is also available in the online help of your single via solutions. On your workstation, open the single via client and log on. If a new version is available, the Update News notification window will pop up. Click on the window to see more information. In this example the new version vbadh. Is available. For more details about the enhancements in the current and new versions, click on the help icon. This section contains documentation about the current version and the new version single via VB80H with the corresponding single via base version VB60I. In this example. In the Show Reminders section you can set the parameters for this notification popup window. If you missed the notification popup window, you can also open it from the help section of your single via client. Open the signal via Administration portal and log on. Select the Installation tab, then choose the Automatic Software Update section. In this example the VB ADH new version is available. To schedule the activation of the new version, select a date and time and the Activation date and time section. In this example, we choose to schedule the automatic activation for May 31st at 7:30 AM. If ignore logged in users is not activated, the system will wait 90 minutes for clients to disconnect if. Users are still connected after 90 minutes. The activation will need to be rescheduled. If the user check should not be performed, the Ignore logged in users option can be activated. After your selection, click Save to apply the changes In a cluster environment. You can also. Schedule the. Activation of the new version independently. However, the activation dates must be within three days of each other to ensure that the synchronization of the nodes can be done quickly after the servers have been activated to the new version. Starting with the VBADG version, you can allow the system to automatically activate the new available version by. Selecting this checkbox after three weeks of successful virtual machine preparation, the Single VIA system will automatically schedule the activation within one week. Default is Sunday. Users and administrators will be notified through the Single VIA client and the event notification feature that a new version will be activated within one week. This automatic scheduled activation can be rescheduled at any time by the user if needed. This will cancel the automatic scheduled activation. Please note that this feature will be also available for multi server cluster configurations starting with single via versions VB, ADH and VC10B. If you instead want to update your system right away, select Now and click on the Save button. The ignore logged in user option is not usable in this. Case a warning window will appear. If. Users are working with the system. They will be disconnected by clicking on Apply you. Start the. Activation of the new version. After a few minutes of activation, the system will reboot. Please note the system will be. Unavailable for. 30 to 60 minutes. During this phase, if something goes wrong with the activation, the system will automatically roll back. Several mechanisms are in place to prevent the system from being blocked at this step. Do not switch off or. Reboot the system while the installation is running. Once the installation is successful and the system is accessible again via local or remote desktop session, a pop up message will indicate the status of the installation. You can now log on to the single VIA system. The Software Update window indicates the status of the activation process. Press any button to continue. Next, log on to the single via Administration portal. To check if additional tasks need. To be completed. In the Automatic Software Update section, you can see that the latest version has been successfully installed. To check details, click the Status Monitoring icon. In the Component View tab, the Software Update section shows pending tasks after the update. In this example, the Open Apps MMM Research Frontier component has pending tasks. Click the component to see more information. Details for the. Status of a component can be also seen through the tooltip. If a failure message appears, contact the customer care Center for support. You can also set up e-mail notifications for new Single via Software versions. Log on to the Single via Administration portal and open the Technical Configuration tab. In the Site Information tab, select Administrator. In the Event Notifications section, add the SMTP server single via. We'll use to send e-mail notifications. Enter the e-mail addresses for notifications when a new version is available. To. Test your configuration. Click the test button.

18559 1.000 12 19 20 21 24 25 26 29 30 31 14 10 22 23 2025/05/31 77 28 11 27 15 2025/05/23 16 2025/05/24 18 210507-1 999999 10496180 +49123456789 Automatic Software Update activation This training material is based on the medical devices syngo.via VB601. Automatic Software Update activation SIEMENS Healthineers Introduction This video shows you step by step how to perform the activation of a new version of your syngo.via solutions. The new Automatic Software Update feature lets you manage when and how to activate the new version of syngo.via completely on your own. your Please Note: All the information in this video is also available in the Online Help of your syngo.via solutions. Content In this video, you will see: How end-users are notified when a new version is available How to activate the new version How to check if the activation was successful Notification when a new version is available on the syngo.via client Rain to stop syngo.via User Name Password Domain OK Cance Change Password .. Patient Browser Browse More Filters Print DICOM Results (0 results, 2:31:23 PM) Series Workflow Status Workflow Desc ... Patient Name Date of Birth Patient ID Modality Study Descripti ... Instances Search successfully completed Export Update News A new syngo.via version is available and ready for installation Open Patient syngo.via VB80H is available for your system Reasons for Update / Upgrade Bug fixes, performance, stability, serviceability, security improvements and OTS updates. For further information, please click help icon (or press F1 key) Contact your IT Administrator IT Admin: ITAdmin Email: ITAdmin@siemens-healthineers.com Phone: 9876543210 Show Reminders Close Help Date Language English 2 results: syngo.via - VB60 (part of VB80/VC10 solutions) - Addendum - Enhancements in syngo.via VB601 syngo.via - VB60 (part of VB80/VC10 solutions) - Addendum - Update News Enter your search here ... syngo.via - VB60 (part of V ... Enhancements in syngo.via VB601 Q search within page Addendum syngo.vi ... Enhancements in sy ... The following chapter describes the enhancements in syngo.via VB601. The enhancements are an addition to the features and tools described in the baseline documentation available on your system. The features and tools of syngo.via are constantly evolving. Therefore, you may find sections on the Related information same enhancement with the same title in several chapters of this addendum. The description of a feature in a chapter about a newer version of the software supersedes the earlier description of that Starting radial range definition ( ... feature. P02-001-ADD.640.05.01.02, 2024-12-11 13:43:42, Date of first issue: 2021-04 / Revision date: 2025-01 Starting radial range definition (update) Measurements on ultrasound images + Screen layout of the Layout Gallery of MM Reading (update) > Screen layout of the Tool Gallery (update) V Show notifications for this message Show notification badge for this message Study Date a ... Online Training Remote Assistance What's New syngo News About Activating the new version on syngo Flight Reader Windows Server 2022 Standard Evaluation Windows License valid for 174 days User Account Control Do you want to allow this app to make changes to your device? Verified publisher: Siemens Healthineers AG File origin: Hard drive on this computer Show more details Yes No Acrobat Administration Portal syngovia, 999999 syngo.via, VB80G Hardware ID: Click to show Login with User Name Login with Service Key Import Service Key User name: Remember user name Password: Login Free (Full Access) Installation Technical Configuration Clinical Configuration Software Update Last Catalog Update: Not Available System Backup Action Filter: Customer Install Package Name Version File Size Status Info Select Action HS_SY030-25-P_VB80H MB Continue 28.05.2025 Instruction Silent Installation Update Catalog An update to the system version VB80H is available 4 Your current version is VB80G Server Name Activation Date & Time Activation status SYNGOVIA Now 1 Ready for Installation Select Date VCustomer authorizes Siemens Healthineers to schedule and apply available updates/new versions automatically Customer will be informed via Update News and E-mail notification (if configured) that an update/new version will be applied on the added Activation Date&Time. Customer can reschedule or remove the Activation Date&Time. Subject to individual agreements, the Terms of Use shall apply. Reset Select Time May 2025 Sun Mon Wed Thu Sat 02:03 PM Save PM 06:55 AM Apply Configuration While the software is being activated, all syngo.via clients must be dlosed. Depending on the Ignore logged-in Users' setting, activation might not start if clients are still open. Make sure that all syngo.via clients are closed before starting activation. Do not shut down or restart the system while activation is running (-30- 60 minutes). Once the systern is accessible again, please login to Admin Portal and check pending tasks in Systern Status Monitor. Cancel Apply INBLRH18138WSPR INBLRH Tue Wed Thu Fri 16 17 3 4 Sun Mon Tue Wed 13 14 IN 01:30 PM 2025/05/ ... Tue Wed Thu Activ 5 26 01:31 PM While the software is being activated, all syngo.via clients must be closed. Depending on the 'lgnore logged-in Users' setting, activation might not start if . Make sure that all syngo.via clients are closed before starting activation. · Do not shut down or restart the system while activation is running (-30- Once the system is accessible again, please login to Admin Portal and check pending tasks in System Status Monitor. Save is in progress. Please don't switch the page Success Your changes have been saved successfully. 07:30 AM V Customer authorizes Siemens Healthineers to schedule and apply available updates/new versions automatically Customer will be informed via Update News and E-mail notification (if configured) that an update/new version will be applied on the added Activation Date&Time. Custorner can reschedule or remove Please note: This feature will be also available for Multi Server Cluster configurations starting with syngo.via VB80H and VC10B. syngovia / adminuser Depending on the 'Ignore logged-in Users' setting, activation might not start if App Installing update You're about to be signed out Windows will shut down in 1 minute. Restarting Please note: The system will be unavailable for 30 - 60 minutes. Do not switch off or reboot the system while the installation is running. Update to new software version has been performed. Log on to Adminportal and open the System Status Monitor to check for pending tasks. Other user Sign-in options Welcome adminuser Please wait for the Local Session Manager Recycle Bin Restore WinLogon settings: The operation completed successfully. 2024-09-12 07:39:21 Update to new software version has been performed. Log on to Adminportal and open the System Status Monitor to check for pending tasks. Press any key to continue . Windows License valid for 178 days Server Shell Start Server Stop Server Porta yngo Flight syngo.Common.Starter.exe No Value, No Value syngo.via, VB80H There are no packages available according to the filter criteria Ready Your current version is VB80H INBLRH18427WSCL Customer authorizes Siemens Healthineers to schedule and apply available updates/new versions automatically Customer will be informed via Update News and E-mail notification (if configured) that an update/new version will be applied on the added Activation Date&Time. Customer can reschedule or remove the Activation Date&Time. Subject to individual agreements, the Terms of Use shall apply. Search Status Monitoring Component View Asset View Server CPU No updates available for activation Network Ext. HW monitoring Main server Interfaces Data management system Drive D > Short term storage (STS) > Operating system Component: Server Information Component status Last status change n.a Polling interval Extended status information The component changed its state from operational to warning. Reason: a child component changed its state. Enable Multi-Server Cluster MNP Update Installation Properties Med product unknown OpenApps prerequisites Serial number Automated Basic Workflow Test MNP Template Update System Snapshot Save data to server Save data to client Time. Customer can reschedule or remove the Activation waming < Server+Software Update OpenApp: MM Research Frontier Component: Software Update 2025-08-10 05:03:56 Measurands Software update successful History Commands Status < Component: OpenApp: MM Research Frontier 2025-08-12 10:24:21 The wamning state is caused by the measurand 'OpenApps' which is now in warning condition. OpenApps OpenApps license MM_RESEARC ... OpenApps license MM_RESEARCH_FRONTIER is availablel Checking whether the MM Research Frontier should be installed from the Digital Marketplace. Extended status informatior As with the syngo.via VB60 the syngo.via Frontier deployment on a separate server is being discontinued, it is required to download urand 'OpenApps' which is now in warning condition. the research applications from the Digital Marketplace after this installation Extended status informatior A As with the syngo.via VB60 the syngo.via Frontier deployment on a NOW Email notification configuration Recorder n Portal Guide POFs Cestart Server Quick Guide Quick Chent Windows License valid for 173 days Build 20348.fe re Build 20348.fe syngo.via, VB80D e.g. domainlaccountname Site Information System Service Customer Administrator System Type syngovia Installation 2024-09-10 (yyyy-mm-dd) User and Role Administration > DICOM Nodes Material Number 10496180 Handed Over > DICOM Data Handling HS Study Preloading Prediction Serial Number Equipment Number Auditing to Syslog Server Device Guard Material Number If you change any of these values you must restart the system for them to take effect. Clinical Administrator Clinical Administrator (proxy) Name Clinical Admin Phone Number Email Address clinicaladmin@tc.com Mandatory Field IT Administrator IT Administrator (proxy) IT Admin itadmin@tc.com First level support to be provided by IT administrator 1 If you select this check box, the name, email address and phone number of the IT administrator will appear in the About box of your clinical software. Event Notification SMTP Mail Host Enable Event Notification Enable SSL Email Address(es) Use commas (, ) to separate multiple email addresses. Sender Address Test EmailToNotify@ Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | C Siemens Healthineers AG, 2025 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com Health

  • syngovia
  • QR700031615
  • technical
  • admin
  • software update