Siemens Healthineers Academy

Atellica® Solution Module Display Job Aid Version 1.26 and Above

This job aid provides instruction on how to use the functionality of the module display.

SIEMENS Healthineers Atellica® Solution Module Display Job Aid Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: 11-FEB-2022 | HOOD05162003253870 Unrestricted © Siemens Healthineers, 2022 Atellica® Solution SIEMENS Healthineers Module Display Module Display • Each Chemistry and Immunoassay analyzer in a system configuration with a Sample Handler includes an affixed touchscreen module display SIEMENS Healthineers CH-01 LabManager • It allows the operator to perform analyzer specific functions directly at Ready Module State System Fluids Other Supplies Reagent Loader the analyzer without having to use the primary user interface • Each module display includes: • A built in barcode reader to scan system supplies and fluids MT Supplies Pretreatment • A USB port that allows the operator to connect the Emergency Sample Load (ESL) carrier barcode reader to scan samples during ESL operation* • The functions available to the operator include: • View and change the analyzer state • Lock and unlock analyzer covers *Note: ESL mode is an optional feature that allows the operator to continue • Check system fluids, supplies, waste (IM Analyzer), IMT supplies processing samples directly on an analyzer if there is failure of the Sample (CH Analyzer), and reagent loader status Handler, Tube Characterization Station, or Atellica Magline Transport. Refer to • Load system fluids and reagents the Atellica Solution Online Help for more information. 2 Effective Date: 11-FEB-2022 | HOOD05162003253870 Unrestricted © Siemens Healthineers, 2022 Atellica® Solution SIEMENS Healthineers Module Display To view and change the analyzer state using the Module Display: 1. Select the Module State button on the Module Display home screen 2. The current state of the analyzer is displayed 3. Select the shut down, stop, or resume button to change the state of the analyzer SIEMENS ..... Healthineers CH-0 LabManager Module State LabManager Ready Ready 1 Module State System Fluids Other Supplies Reagent Loader CH-MODFRNAME Unlock Front Cover Unlock Back Cover IMT Supplies Pretreatment 2 3 Processing Connected to PCC ? 3 Effective Date: 11-FEB-2022 | HOOD05162003253870 Unrestricted © Siemens Healthineers, 2022 Atellica® Solution SIEMENS Healthineers Module Display To lock and unlock the covers using the Module Display: 1. Select the Module State button on the Module Display home screen 2. Stop the Module 3. Select the Unlock Cover button for either the front or back cover SIEMENS ..... Healthineers CH-0 LabManager Module State LabManager Ready Ready 1 Module State System Fluids Other Supplies Reagent Loader CH-MODFRNAME 3 Unlock Front Cover Unlock Back Cover IMT Supplies Pretreatment Processing 2 Connected to PCC ? 4 Effective Date: 11-FEB-2022 | HOOD05162003253870 Unrestricted © Siemens Healthineers, 2022 Atellica® Solution SIEMENS Healthineers Module Display SIEMENS. Healthineers' CH-01 LabManager To check the system fluids using the Module Display: Ready Module State System Fluids Other Supplies Reagent Loader 1 1. Select the System Fluids button on the module display home screen 2. View the status of the system fluids IMT Supplies Pretreatment 3. If a system fluid bottle needs to be loaded, it can be scanned using the module display scanner IM Analyzer CH Analyzer System Fluids LabManager System Fluids LabManager Ready Ready 2 10 11 Tighten the cap before removing the Tighten the cap before removing the fluid container fluid container IM Acid IM Base 6 7 9 CH Conditioner CH Cleaner IM Cleaner 4 5 8 8 CH Diluent CH Wash IM Wash ? ? ----------------------------- 5 Effective Date: 11-FEB-2022 | HOOD05162003253870 Unrestricted © Siemens Healthineers, 2022 Atellica® Solution SIEMENS Healthineers Module Display SIEMENS Healthineers CH-01 LabManager Ready To check the status of the pretreatment pack on the CH Module State System Fluids Other Supplies Reagent Loader Analyzer using the Module Display: 1. Select the Pretreatment button on the module display home screen IMT Supplies Pretreatment 2. View the status of the pretreatment pack 1 3. If a new pretreatment needs to be loaded, it can be scanned using the module display scanner Pretreatment LabManager Scanning Instruction Note: Before replacing the X Ready 3 pretreatment pack, the analyzer must be stopped. Pretreatment For detailed instructions on Lot Instructions for 12345678 Scanning how to replace the L pretreatment pack, refer to Lot Expiration 1/12/2019 150 mm / 6 in L either Online Help or the OBS Changing Pretreatment Pack 180d 10 h on the Atellica® CH 2 Status OK (110 Counts Remaining) Analyzer with Sample Handler Video on Manual Entry ? 45 PEPconnect. 6 Effective Date: 11-FEB-2022 | HOOD05162003253870 Unrestricted © Siemens Healthineers, 2022 Atellica® Solution SIEMENS Healthineers Module Display To view the status of the IMT supplies on the CH Analyzer: 1. Select the IMT Supplies button on the module display home screen 2. View the status of IMT sensor and IMT Fluids SIEMENS ..... Healthineers CH-0 LabManager IMT Supplies LabManager Ready 2 i IMT Maintenance is Due X Module State System Fluids Other Supplies Reagent Loader The IMT Advanced Clean Maintenance procedure is due. To begin the IMT Advanced Clean before replacing the A-LYTE Multisensor, select Perform IMT Advanced Clean To replace IMT Supplies directly without petforming the IMT Advanced Clean, select Replace IMT Supplies To exit select Cancel 1 IMT Supplies Pretreatment ? Perform IMT Advanced Clean Replace IMT Supplies Cancel Pause the IMT ? 7 Effective Date: 11-FEB-2022 | HOOD05162003253870 Unrestricted © Siemens Healthineers, 2022 Atellica® Solution SIEMENS Healthineers Module Display To view the status of the supplies on the IM Analyzer: 1. Select the Supplies button on the module display home screen 2. View the status of the Tips, Cuvettes, and Water SIEMENS. Healthineers IM-01 LabManager Other Supplies LabManager Ready Ready Module State System Fluids Other Supplies Reagent Loader 2 Tips Below Threshold 5 Packs Available to Load 2 Tip Trays in Storage 1 Cuvettes Empty Waste 3 Water OK Humidity Pack OK 90 Counts Remaining ? 8 Effective Date: 11-FEB-2022 | HOOD05162003253870 Unrestricted © Siemens Healthineers, 2022 Atellica® Solution SIEMENS Healthineers Module Display To view the status of the waste on the IM Analyzer: 1. Select the Waste button on the module display home screen 2. View the status of the Cuvette and Tip Waste, Tip Tray Waste, and Liquid Waste 3. If the tip tray waste needs to be emptied, use the Open Tip Tray Waste Drawer button to open the tip tray waste drawer SIEMENS Healthineers' IM-01 LabManager Waste LabManager Ready Ready Module State System Fluids Other Supplies Reagent Loader 2 Cuvette and Tip Waste Above Threshold Tip Tray Waste Waste Full Open Tip Tray Waste Drawer 3 1 Liquid Waste OK ? 9 Effective Date: 11-FEB-2022 | HOOD05162003253870 Unrestricted © Siemens Healthineers, 2022 Atellica® Solution SIEMENS Healthineers Module Display SIEMENS Healthineers IM-01 LabManager Ready To view the status of reagents in the reagent loader: Module State System Fluids Other Supplies Reagent Loader 1 1. Select the Reagent Loader button on the module display home screen 2. View the status of the reagents in the reagent loader Waste IM Analyzer CH Analyzer Reagent Loader LabManager Reagent Loader LabManager Ready Drawer is closed Ready Reagent Loader Lid Closed 2 TSH 160 Tests Reagent Drawer 2 6 5 4 3 2 1 2 DIG 210 Tests DHDL 3 COR Expired AAG P1 Manual Entry Bnz200 P1 Barcode Error aHCVA 120 mL Clear All Positions 160 Tests 210 Tests 0 Tests Barcode Error Undefined 5 Barcode Error Barcode Error ? 10 Effective Date: 11-FEB-2022 | HOOD05162003253870 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 11 Effective Date: 11-FEB-2022 | HOOD05162003253870 Unrestricted © Siemens Healthineers, 2022

  • attelica
  • attellica
  • atelica