Atellica® Sealer Configurations Job Aid
This job aid provides instructions on sealer configurations for the Atellica® Solution.
Sealer Configurations Job Aid Atellica® Sealer The Sealer is meant to complement the Archiving and Test Sort Group features. It is not intended to seal tubes that are not being Archived or are not part of sorting configurations. Note: For a general overview of using Test Sort Groups, refer to the Atellica Solution Sample Han- dler Sorting Online Training on PEPconnect (attached to this training is a Job Aid that includes in- formation on both Sorting and Archiving). For more information on the Archiving and Test Sort Group features, refer to Online Help. To set the seal strength: 1. Navigate to SH & Sorting Configurations > Sample Workflow 2. Select the Sealing Strength from the dropdown: • Low - not recommended for polypropylene or mixed material type tubes. Recom- mended for polyethylene terephthalate (PET) material type tubes to avoid tube de- formation • Medium - recommended for polypropylene or mixed material type tubes • High - recommended for polypropylene or mixed material type tubes for ground transport or freezer storage. PET material type tubes sealed using the High seal strength could experience tube deformation 3. Select Save ‹ A Setup > SH and Sorting Configuration SHI Sort Groups To make configuration changes, stop all Sample Handlers Error Sort Groups Wait for Results Workflow Capillary Tube Setting Test Sort Groups Time to hold sample for repeat or reflex Skip sample volume check for capillary tubes 0 Minutes Sort Priorities Wait for results before moving samples to the output area Off Rack Processing Not Waiting for Results Waiting for Results Decapper Settings Archive Racks Decap Tubes with No Work 1 Sample Worldlow 6AM Atc_3 » « Sample Processing ATC_E ATC_H Sealer Settings 2 O Cal-QC Storage AMG AAT Sealing Strength Low ACE Acet Low Al AlbP Medium Aldo ALP_20 High ALT ALTPLC Amik Amm Amp1k Amp300 Amp500 AMY_2 Amylas APO A1 APO B ARCHV ASO_2 AST 3 Restore Defaults Save Cancel SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date: 10 Aug 2021 | HILS 2224 Healthineers Job Aid Effective Date: 05 JUL 2022 | HOOD05162003284216 Job Aid | Sealer Configurations Effective Date: 05 JUL 2022 | HOOD05162003284216 To configure the system to seal Archive tubes: 1. Navigate to SH & Sorting Configurations > Sample Workflow 2. Select the Seal Archiving Samples checkbox Note: This setting only displays if Enable Rack Archive Management is enabled on the Archive Racks screen. 3. Select Save < Setup > SH & Sorting Configuration 8 SH1-SCI1 LabManager Sort Groups i To make configuration changes, stop all Sample Handlers Error Sort Groups Wait for Results Workflow Capillary Tube Setting Test Sort Groups Time after Results before moving a Sample 0 Minutes Skip sample volume check for Capillary Tubes Sort Priorities Wait for Results before moving samples to the Output Area Rack Processing Decapper Settings Wait for Results before moving Samples to the Archive Area All Results Decap Samples with No Work Archive Racks Wait for Results before moving Samples to the LAS 1 Sample Workflow Not Waiting for Results Waiting for Results Sealer Settings 2 Seal Archiving Samples Sealing Type aHAVM sample Processing aHCV < Amylas v ALB Alb CKMB Cal-QC Storage Sample Tube Sorting ALT Amylas Suspend Sorting BNP Bnz200 BR C Archive Settings Ca CA125 Archive STAT Samples Carb CEA Cho12 CKMB CL Com DHDL Dig DMX eHIV 3 Restore Defaults Save Cancel SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 2 of 5 Job Aid | Sealer Configurations Effective Date: 05 JUL 2022 | HOOD05162003284216 To configure the system to seal tubes that are sorted as part of a Test Sort Group: 1. Navigate to SH & Sorting Configurations > Sort Groups > Test Sort Groups 2. Select the appropriate Test Sort Group 3. Select the Seal Sample Tubes checkbox 4. Select Save Note: This setting is configured individually for each Test Sort Group. Tubes are sealed before they are moved to the output Sort drawer. Setup > SH & Sorting Configuration 8 SH1-SCI1 LabManag Sort Groups To make configuration changes, stop all Sample Handlers Error Sort Groups 1 Test Sort Groups 2 Selected Sort Group Test Sort Groups Pediatrics / X Decap Sample Tubes 3 sort Priorities If Needed for Analysis Seal Sample Tubes Diabetic Rack Processing Routine Tests / X Test Selections Archive Racks Test Type All AAG, AFP, BNP, VitD, UPro Hemo X Sample Workflow DOA / X X Tests Sample Processing Add New Sort Group + X AA Cal-QC Storage X AF X BIN X Vit X UPro 4 Sort Test Definition Save Cancel SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 3 of 5 Job Aid | Sealer Configurations Effective Date: 05 JUL 2022 | HOOD05162003284216 To configure the system to add sealer errors to an Error Sort Group: 1. Navigate to SH & Sorting Configurations > Sort Groups > Error Sort Groups 2. Select the appropriate Error Sort Group 3. Select the Sealer Error option 4. Select Save Note: No tubes in error sort groups are sealed. ‹ n Setup > SH & Sorting Configuration 8 SH1-SCI1 LabManager Sort Groups To make configuration changes, stop all Sample Handlers 1 Error Sort Groups Test Sort Groups Error Sort Groups 2 Selected Sort Group : Lab Default Group Lab Default Group / X Select Error Statuses to add to the selected Error Sort Group Sort Priorities HIL Error Group / X Rack Processing Errors detected by Tube Vision System Add New Sort Group + Barcode Error Cap Error Invalid Tube Archive Racks Sample Workflow Errors detected by a Module 3 Sample Processing Sample Error HIL Error Decapper Error ealer Error Cal-QC Storage Errors detected by System Duplicate Sample ID No Order Whole Blood Timeout 4 Save Cancel SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 4 of 5 Job Aid | Sealer Configurations Effective Date: 05 JUL 2022 | HOOD05162003284216 Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (here- inafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2022 Master Template Effective Date 10 Aug 2021 | HILS 2224 Healthineers Page 5 of 5
- attelica
- attellica
- atelica