Atellica® DT 250 Perform Daily Maintenance Online Training
This course covers the daily maintenance routine for the Atellica DT 250 analyzer.
Continue Continue Continue Continue Continue Continue Continue Continue Continue Untitled Scene Master Template HILS2218 | Effective Date: 2 Jan 2025 Perform Daily Maintenance Atellica® DT 250 Welcome atellicadt250_dailymaint1.mp3 Welcome to the Perform Daily Maintenance Online Training. We will learn about the daily maintenance routine for the Atellica® DT 250 analyzer. ? Daily Maintenance Daily maintenance involves: Inspecting and Cleaning the Probe Replacement of System Liquids & Emptying Waste Container Cuvette Water Blank Select the tab arrows to learn more about each task. Inspecting and Cleaning the Probe Replacement of System Liquids & Emptying Waste Container Cuvette Water Blank Daily Maintenance atellicadt250_dailymaint2a.mp3 Main: Daily maintenance is required for this analyzer. Select the tab arrows to learn more about each task. atellicadt250_dailymaint2.mp3 Inspecting and Cleaning the Probe: Inspect the probe every day and clean it as necessary. It must be cleaned weekly at minimum. Gently remove the protein deposits or solids from the tip with a cotton swab soaked in Solution 1. Dry the probe with a lint-free tissue. Never use abrasive material, as this would damage the delicate tip. atellicadt250_dailymaint3.mp3 Replacement of System Liquids & Emptying Waste Container: Check and replace the System Water and Cleaner solution daily before each instrument start-up. In case of insufficient fluid levels, a warning message will appear after initialization. The instrument will not operate until sufficient amount of System Water and Cleaner is present. Check the volume of the tip cleaning and rinsing solutions, and if they are low, refill them. Check the waste container, and if it is full, dispose of its contents. Ensure that the container lids are closed tightly to prevent leakage or letting fluids into the environment. atellicadt250_dailymaint4.mp3 Cuvette Water Blank: To access the Cuvette Water Blank, select Settings from the main screen. Then, select Maintenance and select Cuvette Blank. Select Start to initiate the process, which takes approximately 15 minutes. Washers will dispense System Water in all cuvettes and the photometer will record the background measurement of each cuvette with all the 12 filters. The first 40 cuvettes are filled, the absorbances are read, the cuvettes are dried, then the other 40 cuvettes are filled, read, and dried. The cuvettes that meet the criteria will be marked as clean. The cuvettes that do not meet the criteria will be marked as unusable, and the system will exclude them from using for measurements. Continue Continue Please review all tabs before proceeding to the next section. Cuvette Water Blank Replacement of System Liquids & Emptying Waste Container Check fluid levels Replace System Water and Cleaner solution daily Replace Tip Cleaning and Rinsing solutions if necessary Empty waste container if full Note: Never leave the System Water and Cleaner solutions uncapped Inspecting and Cleaning the Probe Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc., or its affiliates. All other trademarks are the property of their respective owners Unrestricted | Published by Siemens Healthineers AG | © Siemens Healthineers AG, 2025 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com Disclaimer Exit ? You have completed the Atellica® DT 250 Perform Daily Maintenance Online Training. Completion details, certificates tab Navigation Help Select the icon above to open the table of contents. Click Next to continue. Next Welcome Slide The timeline displays the slide progression. Slide the orange bar backwards to rewind the timeline. Click Next to continue. Next Timeline Select the CC icon to display closed captioning (subtitles). Click Next to continue. Next Caption Icon add subtitles Select the buttons to learn more about a topic. Be sure to review all topics before navigating to the next slide. Click Next to continue. Next Tab Arrow Slide Select the X to close the pop-up. Click Next to continue. Next Layer Slide Select Submit to record your response. Click the X in the upper right corner to exit the navigation help. Assessment Slide Question Bank 1 QR700028976 | Effective Date: 24 Sept 2025 Siemens Healthineers Here are some useful links and documents: 1.1 Welcome 1.2 Daily Maintenance 1.3 Disclaimer
- atellica
- dt
- 250
- analyzer
- system
- overview
- hardware
- software
- drug
- testing