Atellica® DT 250 Order and Load Quality Control Video
This video demonstrates how to order and load quality control on the Atellica DT 250 analyzer.
In this video, we will demonstrate how to order and load quality control QC onto the Atelica DT-250 Analyzer. Let's begin by learning how to order QC. Start by selecting the Quality control icon in the menu bar. Then select the Controls button. Depending on the type of QC you are ordering, select either the Qualitative or Quantitative radio button. In this example, let's order qualitative QC. Verify the qualitative radio button is selected, then select New from a new control window. Select a control set, then select at least one test to be performed by utilizing the check boxes next to the test column. If you would like to perform the QC tests multiple times, update the Replicates column. When complete, select OK to confirm your input. Now let's navigate to the sample tray screen to load our QC. Select the sample tray icon in the menu bar, select an available sector from a sector list, and then select Place Sample from the Place Sample window. Use the arrows to locate and select the Controls tab, then select the QC we ordered. Select Place All to automatically assign the QC levels sequentially to available sector positions or to manually assign the QC levels to specific sector positions. Select the positions from the Positions field and then select Place. Next, select Secondary to process the QC from micro sample cups. The ring around the sector positions indicates secondary mode. Pipe at the control levels into the sample cups and then select Place Sector. Load the sector into the sample tray loading area. Once the sector is properly secured and the sliding cover is closed, select OK. Finally, navigate to the main screen by selecting the main screen icon in the menu bar. From here, select the Start button to begin analysis.
01:35 567890 00:00 21:05 9/9/9999 0.084 0.075 0.032 0.044 0.071 0.034 0.045 0.031 0.025 0.037 0.086 0.07 0.03 19 17 15 11 13 18 16 14 10 12 Master Template HILS2218 | Effective Date: 2 Jan 2025 Order and Load Quality Control Atellica® DT 250 SIEMENS Atellica DT 250 Main Reaction Pending Autoanalyzer Activity Tests in Progress Calculated Pending Estimated Time to Completion 9:13 PM Method ID Sample ID Calibration pending acc. Run Options Next Deferred Dispensing Lido Do Not Stop Operation Next Reading Amik Reagent blank pending acc. Remaining Tests Remaining Readings QC Pending System Messages Event Time Row Item Automatic Clot Calibration Maintenance In Tray Volume Calibrated # Tests # Available Cuvette Blank System Flush Tip Cleaning Reaction Tray Full Fluid Levels Severity Leve Observation Aux. Off System Alerts Calibration Required +C15 Reagent Blank Required System Log 50 % 11 % 100 % +C30 +EX3 Connection Waste (S3) Sys. Water (S4) Cleaner +EX5 Offline Operating LIMS System Water Cleaner Auxiliary Pumps Healthineers Atellica DT 250 Quality Control Reaction pending acc. Control Type O Qualitative Controls Quantitative Calculated pending acc. Pending Test # Pos / Neg Min Separation Lot Number Statistics Pending Calibration Expiration Pending QC Done Position Cumulative Sector Historic Maintenance Required Twin QC Cuvette blank Required System flush Required Scheduler Tip cleaning Required Set New - F2 Delete - F3 Add Test - F5 Delete Test - F6 Delete All Level 0 New Control Control Set Y1 6AM 10Q 1 Negative AMPH 1KQ AMPH 300Q AMPH 500Q BARB 200Q BARB 300Q BENZ 200Q BENZ 300Q BUPN 5Q COC 150Q COC 300Q Ok Cancel Atellica DT 250 Sample Tray Sector operation Waiting Positioning Confirming Place Sector Remove Sector Empty Sector Place Sample Remove Sample Primary Secondary Calibrators Positions Place Place All Exit System Open Calibration Pending Reagent Blank Pending Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc ., or its affiliates. All other trademarks are the property of their respective owners Unrestricted | Published by Siemens Healthineers AG | @ Siemens Healthineers AG, 2025 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com
- atellica
- dt
- 250
- analyzer
- system
- overview
- hardware
- software
- drug
- testing