Atellica® DT 250 Order and Load a Sample Video

This video demonstrates how to order and load samples onto the Atellica DT 250 analyzer.

In this video we will demonstrate how to order samples and load non barcode samples onto the Atelica DT-250 Analyzer. Let's begin by learning how to order a patient sample. Start by selecting the Samples icon in the menu bar. Select New. A sample ID is automatically generated by the software. Edit the sample ID if necessary, and define any additional sample information. To designate the sample as a stat sample, select the Stat Sample checkbox. To enter corresponding patient information. Select the New patient icon next to the Patient ID field. A screen with the available ID, last names, and first names opens and the selection can be made or you can enter the patient information. Then select the grey + icon to the right of the last name field to confirm your input. Finally, double click on a displayed method or profile to add tests to the sample. Now let's navigate to the sample tray screen To load our sample. Select the sample tray icon in the menu bar. Select an available sector from the sector list. In this example, we will select Sector One and then select Place Sample from the Place Sample window. Verify the Samples tab is selected, then select the sample we ordered. Manually assign the sample to a sector position by selecting a position from the Positions field, and then select Place or select Place All to automatically assign the sample to the next available sector position. Then select Exit to return to the sample tray screen. Our place sample is indicated by the green position one in the displayed sector. To view more information, hover over the sector position. The complete list of samples appears on the right panel. The current state is primary and the sample will run in a standard sample tube. To run the sample in a sample cup, right click on the sample position and select Secondary. A Gray ring around the sector position indicates secondary mode. To return to the original setting, right click on the sector position and select Primary. Aliquot the sample into a sample tube or sample cup and place it in position 1 of sector one. Then select Place Sector. The sample tray drives the first available sector position to the sample tray loading area. Slide open the sample tray loading area, remove the old sector, if any, and place the new one. Once the sector is properly secured and the sliding cover is closed, select OK Note do not press OK before you have physically placed the sector in the sample tray and have closed the sliding cover, since the sample tray will start moving immediately upon pressing the OK button. Finally, navigate to the main screen by selecting the main screen icon in the menu bar. From here, select the Start button to begin analysis.

01:35 567890 00:00 21:05 82 8/21/2025 11223344 7/16/2003 19 17 15 13 11 18 16 10 12 14 Master Template HILS2218 | Effective Date: 2 Jan 2025 Order and Load a Sample Atellica® DT 250 SIEMENS . Atellica DT 250 Sample Tray Reaction Pending Autoanalyzer Activity Tests in Progress Calculated Pending Estimated Time to Completion 9:13 PM Method ID Sample ID Calibration Pending Run Options Next Deferred Dispensing Lido Do Not Stop Operation Next Reading Amik Reagent blank pending acc. Remaining Tests Remaining Readings QC Pending System Messages Event Time Row Item Automatic Clot Calibration Maintenance In Tray Volume Calibrated # Tests # Available Cuvette Blank System Flush Tip Cleaning Reaction Tray Full Fluid Levels Severity Leve Observation Aux. Off System Alerts Calibration Required +C15 Reagent Blank Required System Log 50 % 11 % 100 % +C30 +EX3 Connection Waste (S3) Sys. Water (S4) Cleaner +EX5 Offline Operating LIMS System Water Cleaner Auxiliary Pumps +BUP Reaction pending acc. John Smith Calculated pending acc. Urine Sector Sample Type First Name Mike Calibration pending acc. Reference Class ADULT Last Name Smith Position Manually Diluted Factor Stat Sample Place Pending Calibration Test Replicate Status Result 6AM 10Q User 1 Pending QC 6AM 10S user 2 BENZ 200/300S 1 Idle AMPH 1KQ 2 Idle AMPH 300Q BENZ 200Q AMPH 300S AMPH 500/1KS AMPH 500Q BARB 200/300S Maintenance Required BARB 200Q BARB 300Q Cuvette blank Required BENZ 300Q System flush Required BUPN 5Q BUPN 5S Tip cleaning Required COC 150/300S COC 150Q COC 300Q CREATININE EDDP 100Q EDDP 300Q EDDPs New - F2 Delete - F3 Copy - F4 Add Test - F5 Delete Test - F6 Browse Delete All Healthineers Manually Dilute ce Res John Reference Class Birth Date ADULT Section Bed MD Medication Diagnostics ser ser 1 Sector operation Waiting Positioning Confirming Place Sector Remove Sector Empty Sector Place Sample Remove Sample Primary Secondary Samples Controls Positions Place All Exit Sector Id: 1 Position: 1 Sample Id: 123456 Name: Smith John Tests: pH qCOc Open SIEMENS Atellica DT 250 Main Reagent Blank Pending OC Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc ., or its affiliates. All other trademarks are the property of their respective owners Unrestricted | Published by Siemens Healthineers AG | @ Siemens Healthineers AG, 2025 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com

  • atellica
  • dt
  • 250
  • analyzer
  • system
  • overview
  • hardware
  • software
  • drug
  • testing