Atellica® DT 250 Monitor Inventory and Load Reagents and Solutions Video
This video demonstrates how to monitor the inventory and load reagents and solutions onto the Atellica DT 250 analyzer.
In this video, we will demonstrate how to monitor inventory and load reagents and solutions onto the Italica DT-250 Analyzer. Let's begin by learning how to monitor supply and reagent inventories. On the main screen, the Fluid Levels area displays the current fluid levels of the system water, cleaner and waste containers. You can also enable or disable the auxiliary pumps in this area. The Fluid Status area displays any action required with the system fluid containers. Red indicates the container is not connected, yellow indicates the fluid volume is low for the system water and cleaner containers, or yellow indicates the waste is nearly full for the waste container. Note the auxiliary pump will appear in this bar if enabled by service. The item will turn green when the software detects the auxiliary pump module. Now let's learn about the reagent tray screen. Select the reagent tray icon in the menu bar. The reagent tray screen displays A graphical presentation of onboard reagents and solutions and utilizes color-coded positions. Green indicates the reagent is in position and in use. Blue indicates diluents and cleaning solutions. Yellow indicates reagents not in use, light or dark Gray with a position number indicates a free position or a reagent or solution has been removed. Dark Gray with a reagent ID or solution name indicates additional action is required, for example removing the solution and red indicates no active calibration exists for the reagent. Note reagents marked as red are only shown in calibrated view. This can be selected from the calibrated radio button. To see additional information about a specific on board position, hover over a position. Here you will find information including method name and reagent number, number of tests that can be performed with the present volume, number of pending reactions for the method, date the reagent was placed on board, and expiration date of the specific lot. To test the volumes of all reagent and solution containers on board, select Check Volumes and to generate a report about the reagents and available tests, select Available Tests. Note more than one bottle for each method can be defined or inserted. If so, when the first defined vial is exhausted, the reagent intake will automatically be transferred to the next one. Multiple lots of the same reagent can also be placed simultaneously on the reagent tray and separately calibrated. Now let's learn how to load reagents. From the reagent tray screen, select Place Reagent or right click on a desired reagent tray position and select Place Reagent. Select the desired test and position number. From the Reagent ID dropdown. Select OK Enter the reagent information. If you're using a barcode reader, scan the barcode on the reagent packaging or to manually enter the reagent information, enter the reagent's lot number and expiration date, then select OK. Select Apply Changes to move the reagent tray to the selected position. Remove either the small reagent tray cover or remove the entire cover. Place the reagent in the reagent tray. Replace the reagent tray cover. Now let's learn how to load solutions. Select Place Solution or right click on a desired reagent tray position and select Place Cleaning Solution. Select the desired solution and position from the cleaning solution drop down. For more information on how to prepare system solutions, refer to the Prepare System Solutions Job Aid. Select OK Select Apply Changes to move the reagent tray to the selected position. Remove either the small reagent tray cover or remove the entire cover. Place the solution in the reagent tray. Replace the reagent tray cover.
01:35 567890 00:00 21:05 50% 11% 42 44 43 41 45 40 21 22 46 10 11 23 39 47 38 12 48 19 24 37 25 18 36 35 17 14 34 28 33 16 29 31 32 8/21/2026 10/16/2025 20 8/21/2025 154 26 123456 12/31/2025 2/31/2025 Master Template HILS2218 | Effective Date: 2 Jan 2025 Monitor Inventory and Load Reagents and Solutions Atellica® DT 250 SIEMENS . Healthineers Atellica DT 250 Main Reaction Pending Autoanalyzer Activity Tests in Progress Calculated pending acc. Estimated Time to Completion 9:13 PM Method ID Sample ID Calibration pending acc. Run Options Next Deferred Dispensing Lid Do Not Stop Operation Next Reading Amik Reagent blank pending acc. Remaining Tests Remaining Readings QC Pending System Messages Event Time Row Item Automatic Clot Calibration Maintenance In Tray Volume Calibrated # Tests # Available Cuvette Blank Lido System Flush Tip Cleaning Reaction Tray Full Fluid Levels Severity Level Observation Aux. Off +BUP Calibration Required System Alerts +C15 Reagent Blank Required System Log 100 % +C30 +EX3 Connection Waste (S3) Sys. Water (S4) Cleaner +EX5 Offline Operating LIMS System Water Cleaner Auxiliary Pumps 11 % 50 % Atellica DT 250 Reagent Tray Reaction pending acc. BENZ* Pending Calibration Pending QC Week Maintenance Required (S1 (S2) Cuvette blank Required View System flush Required O Normal MPA Tip cleaning Required Tray operation Waiting Positioning Confirming Place Reagent Place Solution Available Tests Remove All In Memory Apply Changes Remove Reagent Remove Solution Check Volumes Method: BENZ 200/300S Reagent: Expiration: Pending tests: On board: Valid until: Place Cleaning Solution Place Diluent Solution Refill Remove Calculated Pending Reagent ID pH Assay qBARB - 1 qBARB - 2 qCOc - 1 qCOC - 2 qTHC - 1 O Calibrated OK Cancel Sector Place Available Apply Check Method: qBARB Reagent: 1 Lot Number: 123456 Expiration: 02/28/2025 Volume: 30,000 ul Volume Req .: 0 ul Available Tests: 50 Pending Tests: 0 Please use the barcode reader to scan the reagent. qCOC Automatic Barcode Reading Lot Number Expiration (S1) Atellica DT 250 Powered by Syva EMIT SIEMENS BENZ Reaction tray Full Online 39 Place Cleaning Cleaning Solution (S2) Tip Rinse Ok Refer to the Prepare System Solutions Job Aid for more information on how to prepare system solutions . Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc ., or its affiliates. All other trademarks are the property of their respective owners Unrestricted | Published by Siemens Healthineers AG | @ Siemens Healthineers AG, 2025 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com
- atellica
- dt
- 250
- analyzer
- system
- overview
- hardware
- software
- drug
- testing