This video provides an overview of the QC Graph tab and demonstrates how to add QC populations to the QC Graph tab.

The Italica Data Manager QC Graph functionality allows you to plot and compare individual or multiple QC populations on the same graph for troubleshooting purposes. This allows you to easily compare QC populations with multiple QC lots, levels, instruments, and assays on the same chart. This may be helpful to quickly understand if the QC issue is specific to an individual QC material reagent lot, or even specific to an individual instrument. In this video, we will demonstrate how to add a single QC population, multiple QC populations, and QC populations for instrument groups to the QC Graph tab. Let's begin by learning how to add QC populations to the QC Graph tab. Start by selecting QC from the Command bar, then select the Graph tab. By default, the global time range is set to the last seven days. To adjust the global date range for each QC population, utilize the From and To fields to make your selections and then select Apply to filter your QC data to the new date ranges. Now select Add from the QC Population selection window. Select one or more QC populations by utilizing the check boxes next to the desired method names. Then select Select to confirm your input and select Draw Graph. Now let's review the different areas of the QC graph screen. First, let's look at the QC Populations panel. The color to the right of the QC population matches the color of the line within the Levy Jennings graph. The check mark icon allows you to hide or show the QC population on the graph. Note the QC population will still display in the timeline slider below the graph with this option. The next icon enables or disables the display of trend lines on the graph. The pencil icon opens the QC population selection window so you can select a different population, while the X icon removes the QC population group from the graph and timeline slider. Note, if you edit or add another population, remember to select Draw Graph again to populate the data in the Levy Jennings graph. Now let's review the different areas of the Levy Jennings graph. The colored bands represent the QC standard deviations SDS. The green band lies between ±2 SD of the reference value, the yellow band lies between 2:00 to 3:00 SD and -2 to -3 SD of the reference value, and the red band lies above 3 SD or below -3 SD of the reference value, and the plotting characters are color coordinated to reflect severity. Green represents a severity of 0, red represents A severity not equal to 0 white Cross marks represent omitted values, and white circles with a dot represent results with associated comments. Hover over a plotting dot to view additional result information. To hide or show the dots, select the right icon below the chart, and to display horizontal and vertical lines indicating the exact coordinates of the mouse, select the middle icon below the chart. The timeline slider allows you to narrow the date range. Select a data point in the QC graph to populate the legend indicating which population you are viewing and statistics that reflect the selected data currently displayed in the graph. So in this example, statistics are being shown for the selected Amylase QC population within the narrowed time range. To restore the graph to its original date range, select the Magnification icon. Finally, select Clear All to remove all the QC populations from the QC Graph tab. Now let's discuss how to add a QC population group to the QC Graph tab. Start by selecting Add Group within the test field. Enter a test name or double click within the field to select a test from the test selection window. To enter a value within the Lot and or Species fields, repeat the process of manually entering the value or double clicking within the field to select a value from a selection window. If you want to filter the instrument list, you can either manually enter the instrument group, double click within the Instrument Group field to select from the Instrument group selection window, or type within the search field to find an instrument name. From the displayed list of instruments, select one or more instruments. To only display the selected instruments, select the Show Selected Only check box, then select Select to confirm. Finally, select Draw Graph to plot your QC population group to the Levy Jennings graph.

2- 12 107 24 45 -3 11 13 -1 0:00 05/31/2018 00:00 61620 61635 61645 0000 26431 26432 2643 05/01/2018 23 9.00 0.71 7.87 254.96 0.79 9.75 8.91 05/05/2018 05/09/2018 05/13/2018 05/17/2018 05/21/2018 05/25/2018 05/29/2018 80.0 80.07 2.18 30.07 6164 7.8 121.80 112.00 102.20 92.40 12.1 53.20 43.40- 121.80- 63.00 57.1 292 05/17 05/18/2018 05/03/2018 05/07/2018 05/11/2018 215 220 80 85 832 225 430 230 1612 182.80 41.2 182.8 75.4 92 Atellica® Data Manager Review QC Graphs Master Template HILS2218 | Effective Date: 2 Jan 2025 QC Graph Functionality The Atellica Data Manager QC Graph functionality allows you to plot and compare individual or multiple QC populations on the same graph for troubleshooting purposes Easily compare QC populations with multiple QC lots, levels, instruments and assays on the same chart This video will demonstrate how to: · add a single QC population to the QC Graph tab · add multiple QC populations to the QC Graph tab · add QC populations for instrument groups to the QC Graph tab Atellica Data Manager ADMDemo SIEMENS Home Sample Query Browser Review and Edit Archive Traceability Utilities STAT Samples All Samples QC Alerts Shortcuts Tests Instruments Translators Services Patients Total Edit Counters Change Users Order Entry Result entry Password Slide Setup Pending Validated Low Physicians Test Groups Purge Data Rerun Uploaded Scheduled Omitted Medium Review Unknown High My Counters Wizards Hematology in REV EHIV in REV Atellica CC1 Troponin > 15min Outstanding in PND ER samples in REV Results Validation Overview sysman, Systemmanager Tuesday, June 24, 2025 - 14:47 QC Alerts Graph QC Population Status Filter Details Lot/Species Assessed String value Unit PMA Algorit ... MS PS WS IS CS Comments Instrument Comments Instrument Group Parse Comments From Today Failed Westgard Comments To User Comments Type Any Lot Flags Species Sort by Test-Lot-Assessed-Inst Include closed out User Actions Mean CV% Show Graph Show Result Details Apply Omit Add Comment Reset Severity 1 2 3 QC Populations Levey-Jennings Graph Use Global Range Add Add Group Clear All Draw Graph N: 0 Mean: - SD: - CV%: CV%: N: 0 Mean: - S : - CV%: QC Populations selection Method Instrument Method Test QC Lot Advia1800_1 AST Human A Ivia2120_1 RBC WBC Atellica1_CH930_1 AMY CA Chol 2 Select Cancel 3 selected Target Deviation 9.8 Cumulative 0 Data range 23 Test CA Lot 26431 Level 1 Instrument Atellica1_CH930_1 SD Target Value 8.91 Current 23 Target Deviation 0.79 Test Chol_2 Lot 26431 Level 1 Target Value 249.0 22 87 Target Deviation 17.5 +4 SD Test AMY Lot 26431 Level 1 +3 SD +2 SD Target Value 82.6 +1 SD - -1 SD -2 SD -4 SD N: 23 Mean: 80.07 SD: 9.75 CV%: 12.18 -3 SD To 05/31/2018 N: 0 Mean: - SD: - CV%: - 4 SD QC Population selection Advia2120_1 12 8 2 SD 9 75 1 SD + N: 23 Mean: 80.07 SD: 9.75 CV%: 12.18 72 80 05/06/2018 - 07:35 Westgard severity: 3 Failed Westgard check(s): * Across lot: 10-x , 4-1s , 1-2s * In lot: 4-1s , 1-2s N: 23 Mean: 254.96 SD: 22.87 CV%: 8.97 Target Value 1 SD - 05/18/2018 - 07:35 * Across lot: 10-x , 1-2s * In lot: 1-2s 05/17 05/18/2018 ADMDemo - -1 SD - N: 13 Mean: 78.17 SD: 12.21 CV%: 15.63 QC Group Selection QC Test Instruments (0 Selected) Search Show Selected Only Test selection Description Ty Sample type Seq no CHCMg Cellular Hemoglobin Concentratio ... S Whole blood Gated Cellular Hemoglobin Conc ... Reticulocyte Cellular Hemoglobin ... CHDWg Gated Content Hemoglobin Distri ... S Reticulocytes Content Hemoglobi ... S CHE Cholinesterase Serum CHg Gated Content Hemoglobin CHIV CHOL Cholesterol Chol_2 CHr Reticulocytes Content Hemoglobin CK Creatine Kinase Name Test Chol 2 Test From 05/01/2018 Instrument group selection Ty .. Atellica IM Nrml Atellica IM group 1 Centaur XPT Nrml Centaur XPT 1,2 He ... Test Chol_2 Instruments Atellica1_CH930_1, Atellica1_CH930_2 Target Value - Current 92 Target Deviation - Data range 92 N: 92 Mean: 182.80 SD: 75.47 CV%: 41.28 Current 182 80 Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc ., or its affiliates. All other trademarks are the property of their respective owners Unrestricted | Published by Siemens Healthineers AG | @ Siemens Healthineers AG, 2025 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com

  • atellica
  • data
  • manager
  • dm
  • adm
  • review
  • quality
  • control
  • levey
  • jennings
  • graph
  • population