Atellica® Data Manager Review QC Alerts Video
This video provides an overview of the QC Alerts tab and demonstrates how to review QC alerts.
To view QC alerts in Intellica Data Manager, we will begin by focusing on the QC Alerts tab from the Command Bar. A QC alert is triggered when the QC severity of an assay is of equal or higher value than the value specified for the QC severity limit. For alerts, unacknowledged QC alerts turn the QC tab red and the QC Alerts tab within the QC screen displays a red_When a QC alert is acknowledged but not resolved, the QC tab displays an alert icon and the QC Alerts tab remains underlined red. Finally, when the QC alert is resolved, both the QC tab and QC Alerts tab display normally. Additionally, a QC severity limit can be defined to prompt an alert for each test on a system, and a severity can be designated as low, medium, or High. Low severity alerts display as yellow, Medium severity alerts display as orange, and High severity alerts display as red. Now let's learn how to review QC alerts. To view all QC alerts, you can select the QC tab from the command bar and then select the Alerts tab. Or to view QC alerts within a selected severity type, you can utilize the QC Alerts chart on the home screen by selecting a portion of the chart, its label, or the chart legend. In this example, let's view all QC Alerts. Start by selecting the QC tab, then select the Alerts tab. Now let's review the main areas of the QC Alerts tab. The Alerts area displays all QC results with a triggered severity, the high severity listed at the top, followed by medium severity and then low severity alerts. When an alert is selected, all QC results for the assay that are associated with the alert triggering QC result will display in the browser. Similar to the QC Results tab. The colored graph columns display the position of the value relative to its population, reference value, and reference deviation. Statistics pertaining to the selected result display below the browser, while the Details panel contains expandable and collapsible content sections for comments, flags, and user actions. Additionally, a user comment can be added to a result by utilizing the pencil icon located in the user comments section. Finally, the button bar below the browser allows you to display result details or Levy Jennings graphs, omit results, add comments, or reset QC severities.
-2 -1 99990 18.4 -5 78.7 108.2 91.66 88.4 118.1 55678 91.6 49.49 28.2 5.36 49.4 151 -3 12 107 45 11 13 24 -4 45.36 9999 100.0 158.9 128.5 Atellica® Data Manager Review QC Alerts Master Template HILS2218 | Effective Date: 2 Jan 2025 SIEMENS ADMDemo Home Sample Query Browser Review and Edit QC Archive Traceability Utilities Results Alerts Graph QC Population Status QC Results Details Test Instrument Lot/Species Assessed String value Unit MS WS IS CS 1 2 GENT Comments Atellica2_CH930_1 Instrument Comments AFP Parse Comments CentaurXP_1 Failed Westgard Comments T3 User Comments T4 Flags VB12 Atellica2_IM1300_1 User Actions AMY Mean SD CV% Target value Show Graph Show Result Details Current Target Deviation 10.0 Cumulative Data range UN Atellica2 CH930 1 Omit Add Comment Reset Severity sysman, Systemmanager Wednesday, July 9, 2025 - 17:10 A QC alert is triggered: when the QC severity of an assay is of equal or higher value than the value specified for the QC severity limit for alerts. T 1 2 3 QC Pop n Status T 12 QC Results (Test: GluH_3, Instrument: Atellica2_CH930_1) GluH_3 08/23/2016 17:00:00 mg/dL GluH 3 PREAG 000050 Lot=459400C;DateTime=8/23/2016 4:55:00 -5 0 1 0 Target Value 100.0 Omitted On 08/24/2016 16:42 Comment: Auto omit for flagged QC Result 08/02/2016 09:00:00 151 0 1 0 H - High cS 45 36 QC Results (Test: T3, Instrument: CentaurXP_1) Tests Instruments Current 0 T 1 2 STAT Samples All Samples QC Alerts Shortcuts Translators Services Patients Total Edit Counters Users Order Entry Result entry Change Password Slide Setup Pending Validated Low Physicians Test Groups Purge Data Rerun Uploaded Scheduled Omitted Medium Review Unknown High My Counters Wizards Hematology in REV EHIV in REV Atellica CC1 Troponin > 15min Outstanding in PND ER samples in REV A 10 Validation Overview Tuesday, April 8, 2025 - 15:05 A QC severity limit can be defined to prompt an alert for entry each test on a system. A severity can be designated as: low, medium, or high. Data A 11 cV% VB1 Cs 08/02/2016 09:00:00 Investigational - Investigational 5 36 Cumulative 0 cs Reinstated On 08/24/2016 16:42 Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc ., or its affiliates. All other trademarks are the property of their respective owners. Unrestricted | Published by Siemens Healthineers AG | @ Siemens Healthineers AG, 2025 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com
- atellica
- data
- manager
- dm
- adm
- review
- quality
- control
- alerts