Atellica® Data Manager Reset QC Severity Video
This video demonstrates how to reset QC severity when a QC result exceeds the assay's QC severity limit.
When a QC result exceeds the Assays QC severity limit in Italica Data Manager, the Test Instrument and String value columns of the QC Results browser remain red until the QC problem is addressed. The operator must then reset the Assays QC severity field to 0 to trigger a new QC result action record. Failure to reset a QC severity to 0 results in the continued reporting of a QC severity error on all subsequent instances of that test on the affected analyzer. To reset a QC severity in Intellicate Data Manager, begin by navigating to the QC Alerts tab. This can be accomplished by either selecting a portion of the QC Alerts donut chart or by selecting QC from the Command bar. In this exercise, let's start by selecting QC from the Command bar, then select the Alerts tab. Select the QC result associated with the assay that needs resetting by selecting the checkbox next to the test name. Note, you can also reset the severity of multiple assays by selecting multiple QC results. In this example, we will select the first AFP result, then select Reset Severity from the Reset QC Severity window. Select the Enable Test after Reset checkbox if appropriate, then enter a comment in the comment field. Select OK. Finally, select F5 on your keyboard to refresh the window to display the reset severity change. If necessary. Repeat this process until all QC severities have been addressed.
-2 47783 28 47782 5.06 84.77 7783 11.8 -1 12 107 24 45 -3 11 13 5.0 75.21 7.17 4.8 17.8 5.8 75.2 9.53 Master Template HILS2218 | Effective Date: 2 Jan 2025 Atellica® Data Manager Reset QC Severity Why reset QC severity? . When a QC result exceeds the assay's QC severity limit, the Test, Instrument, and String value columns of the QC Results Browser remain red until the QC problem is addressed. QC Results (Test: T3, Instrument: CentaurXP_1) Test Instrument Lot/Species Assessed String value Unit MS WS CS T3 CentaurXP_1 08/06/2014 07:05:23 ng/mL 08/02/2014 07:15:31 3.3 0 0 08/01/2014 09:09:33 06/26/2014 09:15:33 5.8 Mean SD CV% Show Graph Show Result Details Target Value 3.0 Current 3 Target Deviation 0.2 Cumulative 0 Data range Omit Add Comment Reset Severity 84 77 0 0 0 0 . The operator must then reset the assay's QC severity field to zero, triggering a new QC result action record. · Failure to reset a QC severity to zero results in the continued reporting of a QC severity error on all subsequent instances of that test on the affected analyzer. SIEMENS Atellica Data Manager ADMDemo - Home Sample Query Browser Review and Edit Archive Traceability Utilities Y Time Period: All ; Refresh Time Interval: 1 minutes STAT Samples All Samples QC Alerts Shortcuts Tests Instruments Translators Services Patients Total Edit Counters Users Order Entry Result entry Change Slide Setup Password Pending Validated Low Rerun Uploaded Physicians Test Groups Purge Data Scheduled Omitted Medium Review Unknown High My Counters Wizards Hematology in REV EHIV in REV Atellica CC1 Troponin > 15min Outstanding in PND ER samples in REV A 11 A 13 A 10 Validation Overview sysman, Systemmanager Tuesday, April 1, 2025 - 18:49 Results QC Population Status Alerts QC Results (Test: AFP, Instrument: CentaurXP_1) Details IS Comments AFP 08/07/2014 07:10:12 Atellica2_CH930_1 08/04/2014 06:15:10 0 0 0 Instrument Comments 08/03/2014 07:11:31 06/26/2014 09:15:33 1 0 0 Failed Westgard Comments Westgard Severity: 5 In lot: 1-3s, 1-2s User Comments T4 VB12 Atellica2_IM1300_1 User Actions AMY Target Value 5.5 Current Target Deviation 1.0 Cumulative Atellica2 CH930 1 Parse Comments Graph GENT UN nstrument AF 5 00 Across lot: 1-3s, 1-2s ADMDemo est Cs Flag Enable Test After Reset Set PMA Value Manual PMA Value: The following tests will have QC Severity reset and comment appended: Disabled by Reagent Change Related Blocked Methods: Reset Related Methods Cur Cancel Data ra OK Flags Rerun ok. QC Results cS 1 2 Current 0 GluH_3 A VB12 Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc ., or its affiliates. All other trademarks are the property of their respective owners Unrestricted | Published by Siemens Healthineers AG | @ Siemens Healthineers AG, 2025 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com
- atellica
- data
- manager
- dm
- adm
- quality
- control
- qc
- reset
- severity
- limit
- assay