
Atellica® Data Manager Manage Test Results Job Aid
This job aid provides instructions on how to manage test results including: validate, rerun, view previous, revert, upload, and common right click menu options.
Atellica® Data Manager – Review and Edit x Sample Query: Samples with Minimal status 'Review', Maximal status 'Review' Request Options: From 'Pending', To "Uploaded" Basic Advanced LAS Sample ID AAA20181114071920 1 DOB 23/10/1975 Priority Routine Sample Manage Test Results Job Aid Patient ID AAA20181114071920 1 Sex Female Collection Time 14/11/2018 09:30:25 Comment Patient Name Sorensen, Bradley, Loren Age 43 Patient Location URG Patient > Comment CBC Images TG_2 Request Options Test Sts Current Unit Norm Current D/T Previous Run Previous DIT NS DS Qs IS Instrument TAT WBC REV 15 x10^3/UL 4.80-10.8 14 / 11 / 2018 07 :19 ? Advia2120_1 1M18d15h5m. RBC REV 20 x10^6/ul ? 4/11/2018 07:19 ? Advia2120_1 1M 18015h5m ... KKK Validate Test Results 1. View all test results by scrolling through the test requests list Select Review Validate Rerun Revert Rerun All 2. The Scroll button becomes the Validate button once all Edit Mode Samples meeting criteria >100 Diff Pad View Previous Upload All tests have been viewed Review and Edit x • Note: If all tests display on the screen, only the Sample Query: Samples with Minimal s .. Request Options: From 'Pending' ... Validate button displays Sample AA_PREVIOUS_PATIENT_RUNS_B Patient Weller, Christy, Patient URG Gender M (Male) Age 22 In Nama Annia Lanation 3. Select the appropriate test(s) by selecting the test CBC V W O DIFF V W checkbox(es) OR utilizing the Select dropdown list to Test Sts Current F Previous Run Test Sts Current F Previous Run WBC REV 1.46 2.46 NEUTP REV 1.46 7.46 RBC REV 7.46 3.46 LYMP REV 6.46 7.46 select tests by sample status HGB REV 6.46 5.46 MONOP REV 5.46 5.46 Request Options HCT REV 5.56516 2.58116 EOSp REV 6.46 0.46 4. Select Validate MCV REV 7.46 0.46 BASOP REV 6.46 1.46 MCH REV 8.65952 18.6705 LUCP REV 0.46 0.46 KK KK KKK KKKKKKK Validate Test Results in Split view RTC/Other V W Test Sts Current F Previous Run Pr Test Sts Current F Previous Run RDWg REV 1.46 6.46 12/0 PDW REV 0.46 7.46 RDWr REV 0.46 1.46 12/( PCT REV 7.46 4.46 1. Vertically Scroll through the panel to view all test results HDWg REV 7.46 7.46 12/1 WBCP REV 4.46 7.46 HDWr REV 4.46 5.46 12/0 WBCB REV 1.46 2.46 CHDWg REV 1.46 1.46 12/0 LI REV 6.46 0.46 2. Select to validate selected tests in a panel CHDWr REV 6.46 6.46 12/ MPXI REV 0.46 4.46 KKKKKKK KK KKKKK Select to validate all tests in a panel 1 Select Review Validate Rerun Revert Rerun All Select Validate to validate the entire sample Samples meeting criteria >100 Diff Pad View Previous Upload All • Note: Validate only works on tests in a Review status or higher Template Effective Date: 10 Aug 2021| HILS2223 Effective Date: 13 Nov 2023 | QR700002267 Unrestricted © Siemens Healthineers, 2023 Atellica® Data Manager – SIEMENS Healthineers Manage Test Results Job Aid Review and Edit Request Options: From 'Pending', To 'Uploaded' E 1 Basic Advanced LAS Sample ID AUT20221207210712806_437 DOB 10/20/2006 Priority Routine Sample Patient ID BB20221207210712807 Gender F (Female) Collection 12/07/2022 Comment > Time 09:30:25 Patient Details Patient Bobo, Leon, Bryan Age 16 Patient URG Comment Validate Test Results (continued) Request Options iii Test Sts Current Unit Norm Current D/T F Previous Run Previous D/T NS DS QS IS V AFP REV 30 ng/ml ? 12/07/2022 21:06 ? ? 2 If Enforce comment when validating critical results setting is enabled, results marked as critical require a user comment before validating the sample 1. Select Validate Select Review Validate Rerun Revert Rerun All 2. From the Review of Result Comments window, Edit Mode Diff Pad View Previous Upload All select the Pencil icon to enable Edit mode Review of Result Comments Critical Result Comments 3. Enter a comment Test AFP 4. Select the Pencil icon to disable Edit mode 5. Select Validate Note: System Administrators can enable the Enforce comment when validating critical results setting, which mandates users enter a comment when validating critical results. Please contact your local technical support provider if you would like to enable this feature. Non-Critical Result Comments Validate Close 2 Template Effective Date: 10 Aug 2021| HILS2223 Effective Date: 13 Nov 2023 | QR700002267 Unrestricted © Siemens Healthineers, 2023 Atellica® Data Manager – Review and Edit x Sample Query: Samples with Minimal status 'Review', Maximal status 'Review' Request Options: From 'Pending', To "Uploaded" Basic Advanced LAS Sample ID AAA20181114071920 1 DOB 23/10/1975 Priority Routine Sample Manage Test Results Job Aid Patient ID AAA20181114071920_1 Sex Female Collection Time 14/11/2018 09:30:25 Comment Patient Name Sorensen, Bradley, Loren Age 43 Patient Location URG Patient Comment CBC Images TG 2 Request Options ¡ iii Test Sts Current Unit Norm Current D/T F Previous Run Previous DIT NS DS QS IS Instrument TAT WBC REV 15 <10^3/uL 4.80-10.8 14/11/2018 07:19 ? ? Advia2120_1 1M 18d15h5m. M RBC REV 20 x10^6/u 14/11/2018 07:19 ? ? Advia2120_1 1M18d15h5m ... Rerun Test Results 1. Select the appropriate test(s) by selecting the test checkbox(es) OR utilizing the Select dropdown list to select tests by sample Select Review Validate Rerun Revert erun All status Edit Mode Samples meeting criteria >100 Diff Pad View Previous Upload All 2. Select Rerun to rerun all selected tests or Rerun All to rerun all Review and Edit x tests displayed in the current tab Y Sample Query: Samples with Minimal s ... Request Options: From 'Pending' ... E Sample AA_PREVIOUS_PATIENT_RUNS_B Patient Weller, Christy, Patient URG Gender M (Male) Age 22 In Name Annia anation CBC DIFF :nw Test Sts Current F Previous Run Test Sts Current F Previous Run Rerun Test Results in Split view WBC REV 1.46 2.46 NEUTP REV 1.46 7.46 RBC REV 7.46 3.46 LYMP REV 6.46 7.46 HGB REV 6.46 5.46 MONOP REV 5.46 5.46 HCT REV 5.56516 2.58116 EOSp REV 6.46 0.46 Request Options Rerun selected tests MCV REV 7.46 0.46 BASOP REV 6.46 1.46 MCH REV 8.65952 18.6705 LUCP REV 0.46 0.46 • Select the appropriate test(s) by selecting the test RTC/Other W ... checkbox(es) and select Rerun Test Sts Current F Previous Run Pr Test Sts Current F Previous Run RDWg REV 1.46 6.46 12/0 PDW REV 0.46 7.46 Rerun all tests in a panel RDWr REV 0.46 1.46 12/0 PCT REV 7.46 4.46 HDWg REV 7.46 7.46 12/0 WBCP REV 4.46 7.46 Select HDWr REV 4.46 5.46 12/6 WBCB REV 1.46 2.46 • CHDWg REV 1.46 1.46 12 /1 LI REV 6.46 0.46 CHDWr REV 6.46 6.46 12/1 MPXI REV 0.46 4.46 Rerun the sample 3 • Select Rerun All Select Review Validate Rerun Revert Rerun All Samples meeting criteria >100 Diff Pad View Previous Upload All Template Effective Date: 10 Aug 2021| HILS2223 Effective Date: 13 Nov 2023 | QR700002267 Unrestricted © Siemens Healthineers, 2023 Atellica® Data Manager – SIEMENS Healthineers Manage Test Results Job Aid Review and Edit x Y Sample Query: Samples with Minimal status 'Review', Maximal status 'Review' Request Options: From 'Pending', To 'Uploaded' Basic Advanced LAS Sample ID AAA20181114071920 1 DOB 23/10/1975 Priority Routine Sample Patient ID AAA20181114071920 1 Sex Female Collection Time 14/11/2018 09:30:25 Comment Patient Name Sorensen, Bradley, Loren Age 43 Patient Location URG Patient Comment View Previous Patient Results and Cytograms CBC Images TG 2 Request Options Test Sts Current Unit Norm Current D/T F Previous Run Previous DIT NS DS QS IS Instrument TAT WBC REV 15 x10^3/UL 4.80-10.8 14/11/2018 07:19 ? Advia2120_1 1M18d15h5m ... 1. Select the appropriate test(s) by selecting the M RBC REV 20 x10^6/uL ? 14/11 / 2018 07:19 Advia2120_1 1M 18d 15h5 m ... test checkbox(es) OR utilizing the Select dropdown list to select tests by sample status 2. Select View Previous 3. Select Previous Patient Data OR Previous Run Data Select Review Validate Rerun Revert Rerun All 4. If viewing Previous Run Data, select a previous Edit Mode Samples meeting criteria >100 Diff Pad View Previous Upload All run from the Run List dropdown 5. Select OK Previous samples of sample S100020 kx patent'OP 126) BASO Court Sunpect 12hY BASO Court Suspect 4 Template Effective Date: 10 Aug 2021| HILS2223 Effective Date: 13 Nov 2023 | QR700002267 Unrestricted © Siemens Healthineers, 2023 Atellica® Data Manager – Review and Edit x Sample Query: Samples with Minimal status 'Review', Maximal status 'Review' Request Options: From 'Pending', To 'Uploaded' Basic Advanced LAS Sample ID AAA20181114071920 1 DOB 23/10/1975 Priority Routine Sample Manage Test Results Job Aid Patient ID AAA20181114071920_1 Sex Female Collection Time 14/11/2018 09:30:25 Comment Patient Name Sorensen, Bradley, Loren Age 43 Patient Location URG Patient Comment CBC Images TG 2 Request Options Test Sts Current Unit Norm Current D/T F Previous Run Previous D/T NS DS QS IS Instrument TAT WBC REV 15 x10^3/UL 4.80-10.8 14/11/2018 07:19 2 Advia2120 1 1M 18d 15h5 m ... RBC REV 20 x10^6/u ? 14/11/2018 07:19 ? Advia2120_1 1M 18d15h5m ... Revert Test Results 1. Select the appropriate test(s) by selecting the test checkbox(es) OR utilizing the Select dropdown list Select Review Validate Rerun Revert Rerun All to select tests by sample status Edit Mode Samples meeting criteria >100 Diff Pad View Previous Upload All 2. Select Revert Review and Edit x 3. In Split View, select to revert all tests in a panel Y Sample Query: Samples with Minimal s ... Request Options: From 'Pending' ... E Sample AA_PREVIOUS_PATIENT_RUNS_B Patient Weller, Christy, Patient URG Gender M (Male) Age 22 In Name Annio Lanation CBC DIFF ... ... Test Sts Current F Previous Run Test Sts Current F Previous Run WBC REV 1.46 2.46 NEUTP REV 1.46 7.46 RBC REV 7.46 3.46 LYMP REV 6.46 7.46 Note: Once a sample status is selected from the Select HGB REV 6.46 5.46 MONOP REV 5.46 5.46 Request Options HCT REV 5.56516 2.58116 EOSp REV 6.46 0.46 dropdown, the selection persists across samples, system MCV REV 7.46 0.46 BASOP REV 6.46 1.46 MCH REV 8.65952 18.6705 LUCP REV 0.46 0.46 KK KK KK K refresh, newly opened Review and Edit browsers and operator sessions. RTC/Other Test Sts Current F Previous Run Pr Test Sts Current F Previous Run RDWg REV 1.46 6.46 12/( PDW REV 0.46 7.46 RDWr REV 0.46 1.46 12/( PCT REV 7.46 4.46 HDWg REV 7.46 7.46 12/( WBCP REV 4.46 7.46 HDWr REV 4.46 5.46 12/( WBCB REV 1.46 2.46 CHDWg REV 1.46 1.46 12/ LI REV 6.46 0.46 CHDWr REV 6.46 6.46 12/( MPXI REV 0.46 4.46 5 Select Review Validate Reru Revert Rerun All Samples meeting criteria >100 Diff Pad View Previous Upload All Template Effective Date: 10 Aug 2021| HILS2223 Effective Date: 13 Nov 2023 | QR700002267 Unrestricted © Siemens Healthineers, 2023 Review and Edit Atellica® Data Manager – Sample Query: Samples with Minimal s .. Request Options: From 'Review'. Basic Advanced LAS Sample AUT20221207210746825 529 DOB 10/18/2018 Priority Routine Sample Manage Test Results Job Aid ID Comment Patient HS20221207210746829 Gender F (Female) Collection 12/07/2022 Patient ID Time 09:30:25 Comment Request Options Test Sts Current Unit Norm Current D/T F Previous Run Previous DIT NS AFP VAL 30 ng/ml 0-8.10 12/07/2022 21:07 ? ? 1 T3 VAL 20 ng/ml 0 . 600 - 1.81 12/07/2022 21:07 ? 1 Upload Test Results T4 VAL 21 ug/dl 4.50-10.9 12/07/2022 21:07 2 1. Ensure that at least one test result is in Validated status Select Review Validate Rerun Revert Rerun Al 2. Select Upload All Edit Mode Samples meeting criteria >100 Diff Pad View Previous Upload All 3. In Split View, select then Upload to upload all Review and Edit x ... tests in a panel Y Sample Query: Samples with Minimal s ... Request Options: From "Validate ... Sample AAA20221207205111_105 Patient Name Brothers, Audra, Patient URG Gender F (Female) Age 37 In Ductin Location CBC nw V nw ... ... Test Sts Current Previous Run Pr Test Sts Current F Previous Run Pr + WBC VAL 15 RBC VAL 20 Request Options Other ... Test Sts Current F Previous Run |Pr Test Sts Current F Previous Run Pr 6 Select Review Validate Rerun Rever Rerun All Samples meeting criteria 3 Diff Pad View Previous Upload All Template Effective Date: 10 Aug 2021| HILS2223 Effective Date: 13 Nov 2023 | QR700002267 Unrestricted © Siemens Healthineers, 2023 Atellica® Data Manager – SIEMENS Healthineers Manage Test Results Job Aid Common Right Click Menu Options Review and Edit x • Advanced rerun: allows the targeting of a specific Y Sample Query: Samples with Minimal status 'Review', Maximal status 'Review' Request Options: From 'Pending', To 'Uploaded' instrument for rerun on the selected test Basic Advanced LAS • Omit: removes the selected order Sample ID AAA20191024143418 100 DOB 07/05/1989 Priority Routine Sample Patient ID AAA20191024143418 100 Sex Female Collection Time 24/10/2019 09:30:25 Comment Related > Results: displays all results, date, time Patient Name Tinsley, Tracie, Danny Age 30 Patient Location URG Patient • Comment and instrument for the selected test CBC Images TG_2 Related > Document: displays any associated Request Options • Test Sts Current Unit Norm Current D/T F Previous Run Previous DIT documents for the sample WBC Advanced rerun Dispatch to LAS 24/10/2019 14:35 • Revert: enables selecting a final result from a list of V RBC Edit result comment 24/10/2019 14:35 results for the selected test Invalidate Omit Unschedule: changes the selected order status to Revert • Set as informational pending making it available to be run on another View result instrument View QC Unschedule View QC: enables viewing of quality control of the Set auto dilution • Related selected test Remove pending instrument cancel messages Set target instrument Set routing cluster 7 Template Effective Date: 10 Aug 2021| HILS2223 Effective Date: 13 Nov 2023 | QR700002267 Unrestricted © Siemens Healthineers, 2023 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc., or its affiliates. All other trademarks are the property of their respective owners © Siemens Healthcare GmbH 2023 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 8 siemens-healthineers.com Template Effective Date: 10 Aug 2021| HILS2223 Effective Date: 13 Nov 2023 | QR700002267 Unrestricted © Siemens Healthineers, 2023
- atellica
- data
- manager
- dm
- adm
- review
- edit
- manage
- test
- result
- rerun
- upload
- related
- omit
- revert
- view
- previous
- validate