
Assigning Layout Rules MI View&GO
Assigning Layout Rules MI View&GO
Creating Layout Rules in MI View&GO Symbia Pro.specta™ MI View&GO - all software versions This job aid is designed for the end user to become familiar with creating and saving initial Layout rules in MI View&GO. Creating a new Layout rule 1. In MI View&GO, select the Configuration Icon to open the Layout rule configuration window. SIEMENS ... Healthineers = Scan 3 = Recon 1 MI View&GO X ...................................................................... MI View&GO Configure initial layout rules Tc99m Sestamibi Basic Dynamic Static Display Time F Topogram 0.70 Tr20 cor [1] WB - Dual Intensity 01/1 2/2018 Sated Stripe 2:51:34 PM ................................................. 2. Select Add to create a new Layout rule. Configuration x Layouts User Presets State Modality Protocol Name |Assignment Object | Assignment Condition | Public Any General Apply Close Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers 3. Type in a name for the new Layout rule’s Protocol Name. Assign Layouts ? X i For a study specified by modality and assignment condition, please drag the layouts to the Preferred Layouts section. The first layout in the list will be your initial layout. Protocol Name Public Layouts Modality Basic Dynamic Static . Static WB - Dual WB Display Time View Intensity Compare Any Assignment Object Planar Savescr ... Dynamic + Static Static Dyn Gated Static CR Stati Study Description Functional Functional Fused 2x3 Fused Fused 2x3 Fused 2x4 Assignment Condition 2×3 + M ... Axial 3x .. Movie Axial 3. Movie NM PARATHYROID SPECT Fused 2x2 Hybrid 3x3 4D 4D Fused 4D Hybrid Preferred Layouts + Movie unctio .. 1x3 + 2X3 + ... VWB + ... Static Dynamic WB Hybrid Lung VQ Hybrid 1x3 Basic Fused Compare Static Compare Compare + Movie Display HIIII Dynamic + Stack 3x2 Stack 2x2 Stack 1x1 Stack 2x1 Stack 3x3 Static .. Stack 4x3 Stack 4x4 Stripe 3x2 Stripe 4x3 Stripe 5x4 Follow Up Accept Cancel 4. Choose a modality if needed. 5. Choose the Assignment Object. Study Description is recommended. 6. Type in or select the Assignment Condition. Include asterisks before and after study names if typing in. See the image below. Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers Page 2 of 7 Assignment Condition "para" 7. Click-and-drag any desired Public Layouts into the Preferred Layouts section. Alternatively, right-click on a desired layout and select Add to Favorites. Modality Basic Dynamic Static - Static WB - Dual WB - Display Time View Intensity Compare NM/CT THE Assignment Object Planar Savescr .. Dynamic + Static Static + Dyn + Gated Static WB CR Stati .. Study Description Functional Functional Fused 2x3 Fused Fused 2x3 Fused 2x4 Assignment Condition 2x3 + M ... Axial 3x ... + Movie Axial 3 + Movie "para" Fused 2x2 Hybrid 3x3 4D 4D Fused 4D Hybrid Compare Preferred Layouts Movie .... Functio. 1x3 2×3 + WB + ... Static Dynamic WB + Fused Fused 2x3 Stallc - Hybrid Lung V/Q Hybrid 1x3 Basic Fused Compare Static ... Compare Compare Movie Axial 3 .. Time Display Dynamic + ack 2x1 8. Click Accept to finish creating the Protocol. Accept Cancel Setting Presets for customized Layout Protocols Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers Page 3 of 7 1. In the Configuratoin window, select the User Presets tab. Configuration ? X Layouts User Presets Choose protocol to configure Initial Workflow Step General None LUT Settings Slice Thickness NM CT PT MR Fused O Use series data for thickness settings Data Type LUT Apply custom thickness settings STATIC Inverted Grayscale 1 4 mm DYNAMIC Inverted Grayscale GATED Inverted Grayscale Slice Spacing WHOLE BODY Inverted Grayscale Apply minimum spacing TOMO Inverted Grayscale Apply percentage value spacing GATED TOMO 0 % of slice thickness Inverted Grayscale Apply absolute value spacing. Mixing Ratio Must not exceed slice thickness. 0 mm Base (100%) Overlay (100%) Save Rese Import Export Close 2. Choose the custom protocol. Choose protocol to configure General Parathyroid General General NM CT PT MR Fused 3. Adjust LUT settings for each relevant modality that will be included in the Layout. Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers Page 4 of 7 LUT Settings NM CT PT MR Fused Data Type LUT DYNAMIC Inverted Grayscale GATED Inverted Grayscale WHOLE BODY Inverted Grayscale TOMO Inverted Grayscale GATED TOMO Inverted Grayscale RECON TOMO Warm Metal Mixing Ratio Base (100%) Overlay (100%) 4. Set an Initial Workflow Step if desired. Initial Workflow Step None MI Cardiology Reading MI Organ Processing Automatic Layout None 5. Adjust slice settings. Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers Page 5 of 7 Slice Thickness Use series data for thickness settings Apply custom thickness settings 1 4 mm Slice Spacing Apply minimum spacing Apply percentage value spacing 0 % of slice thickness Apply absolute value spacing Must not exceed slice thickness. 0 - mm Import Export 6. Click Save to confirm changes. Please note that the learning material is for training purposes only! Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers Page 6 of 7 For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2024 Siemens Healthineers Headquarters Local Contact Information Legal Manufacturer Siemens Healthcare GmbH Siemens Medical Solutions USA, Inc. Siemens Medical Solutions USA, Inc. Henkestr. 127 91052 Erlangen, Germany 40 Liberty Blvd. Molecular Imaging Phone: +49 9131 84-0 Malvern, PA, USA 19355-9998 2501 N. Barrington Road siemens-healthineers.com Telephone: +1-888-826-9702 Hoffman Estates, IL, USA 60192 siemens.com/healthcare Telephone: +1 847 304-7700 siemens.com/mi Unrestricted | Published by Siemens Healthineers AG, 2024 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 2/8/2024 | QR700005257 Healthineers Page 7 of 7
- layout
- rules
- mi
- view&go