Siemens Healthineers Academy

Artis zee multi-purpose - Application features

Get to know the applications and specific features of the Artis zee multi-purpose system.
The following topics are covered:

0:32 Accessories
2:20 Drive the system to the default system positions (Transfer Head Side, Transfer Footside, CPR, Frontal, Lateral, Overtable, Undertable)
6:47 Tilt the tabletop
8:09 Exam room: System overview
8:40 Footswitch: Guard active
9:33 System message: Collision with the monitor system
9:48 Long carriage: Guard active
10:08 3D angulation limitation in Artis zee multi-purpose
10:48 Patient's rescue
 

This video will show you the applications and the specific features of the Artist. C Multi Purpose system when performing the work. Steps. Observe the general safety guidelines for Medical engineering products and the product specific safety information. Here's an overview of the accessories. Attach the hand grips on both sides of the patient table. Attach the footboard. There are two possible positions. Detach the footboard and attach the table accessory rail. You can use this rail, for example, to attach a lead shield. Attach the frame for the accessory holder at the head end of the patient table. Attach the footboard on the holder. This option offers more flexibility to position the patient. Make sure that standard and additional accessories have been delivered with the system. This chapter will show you how to drive the system to the desired selection using the factory default positions. To select the target position, press the Required position key. The corresponding menu appears on the Data Display or Assist screen. Select the required target position by deflecting the Stand or C arm joystick away from or towards you. Repeatedly confirm the target position by pressing one or both side buttons. Press the Stand or C Arm joystick down and deflected away from you until you reach the target position. Attention. Take care to avoid possible collisions. Drive the system to the CPR position. When the system has reached the CPR position, attach the CPR support accessory. Drive the system to the transfer position head side. Drive the system to the transfer position. Foot side. Drive the system to the frontal position. Drive the system to the lateral position. Drive the system to the overtable position. Drive the system to the under table position. Now bring the system into the 90° Trendelenburg positions with the C arm under table and over table. Attach the footboard, press the key for the required movement and keep it pressed until you reach the required table. Tilt the table tilts in Trendelenburg or reverse Trendelenburg direction. Here the C arm is in the under table position. Also, move the C arm to the over table position. Position the tabletop horizontally again, press both keys simultaneously and keep them pressed until the movement stops automatically. Here's an overview of the trolley and its control modules. Rails for control modules and other accessories. Grip cable holder holder for hand switch connectors for control modules Casters. Position the pedal right below the C arm. Drive the patient table towards to the ground. Once the C arm hits the pedal, the assist screen will provide the collision message and the guard will be activated. Attention with the Artessee multi purpose, you can only move the patient foot side vertically to the ground. This might be a clinical scenario if the pedal is placed under the patient table or CR mistakenly. When the patient table hits the pedal, it hits the pedal rail 1st and the movement stops. Move the display ceiling suspension to the middle of the ceiling. Drive the C arm to the Rao. A message on the assist screen appears if someone is standing between the table carriage and the CRA sensor will be activated. See the system message on the assist screen. 3D acquisition is limited to 150° rotational for all organ protocols. Additionally, if the system is right side mounted, 3D acquisition is possible on the left side and additionally in the upright position since VC 21. If the system is left side mounted, 3D acquisition is possible on the right side only. As you can see in this video, the system is right side mounted. In the event of a power failure, motoric system movements aren't available. However, you can move parts of the system manually. Attention during the following steps. Make sure that the patient isn't hurt. You can move the tabletop with the crank handle supplied. You can find the tool on the right behind the support arm. Remove the covering cap and insert the crank handle. Turn the crank handle to set the height of the tabletop.

00:00 Application features Artis zee multi-purpose Artis with PURE® zee SIEMENS Accessories Footboard Hand grips TEMPUR-MED Table accessory rail with frame for accessory holder itis CE rtis Drive the system to the default positions System Positions Cardio Pulmonary Resuscitation Transfer Head Side Transfer Footside Frontal Lateral Overtable Undertable Automap XRAY manually disabled syngo Workplace Artis Live 9.5 mA CPR 112 cm 120 cm 42 cm 0 cm Automatic run: Moving to target -12 cm 5cm -15 cm -20 cm 20 cm -30 cm Automatic run: Position reached 15 cm Automatic run: Activate stand movement 25 cm -35cm 144 cm 0 cm -12 cm 136 cm 122 cm 111 cm 97 cm 84 cm 72 cm 59 cm 46 cm 33 cm 17 cm cm -23 cm 25 cm -32 cm 145 cm 25 cm -35 cm 18 cm 31 cm 44 cm 56 cm 69 cm 83 cm 94 cm 107 cm 121 cm 132 cm -16 cm -22 cm 23 cm -31 cm O cm -12 cm 16 cm -26 cm 11 c 6 cm -16 cm 142 cm 131 cm 118 cm 104 cm 93 cm 79 cm 66 cm 55 cm 41 cm 12 cm 22 cm 36 cm 48 cm 57 cm 103 cm 140 cm 113 cm 86 cm 67 cm 58 cm 49 cm 29 cm 13 cm 61 cm 75 cm 88 cm 100 cm 126 cm 138 cm Tilt the tabletop Artis zee Exam room: System overview Footswitch: Guard active 101 cm Footswitch: GUARD ACTIVE System monitor System message: Collision with the monitor system 90 cm -28 cm Collision with monitor system Long carr Long carriage: 92 cm LONG CARRIAGE: GUARD ACTIVE 3D angulation limitation in Artis zee multi-purpose Pati Patient's rescue Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of utility model or design, are reserved. Unrestricted I Published by Siemens Healthineers AG | C Siemens Healthineers AG, 2024 Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com Healthineers