ARTIS pheno (VE2) 3D Acquisition Video
This video demonstrates the workflow for 3D Acquisitions on your ARTIS pheno VE20.
Please note: Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training.
Target group: Basic user
Audio: Yes
Recommended to be viewed on the following devices: Laptop, desktop computer (sufficiently large display required)
Welcome to the Artis Fino 3D Acquisition video. In this video you will learn the workflow to perform 3D acquisitions. First select the 3D acquisition protocol. If your current exam room display is configured to display the 3D wizard, you can use the 3D Wizard to select the protocol and for acquisition guidance. You select the 3D wizard from the On Screen menu, press the key on the Pilot Control module to open the onscreen menu, deflect the jog wheel to select the general 3D Sharing menu, and select the 3D Wizard. Alternatively, you can open the 3D wizard from the touch screen. In the examination menu, select the 3D Acquisition protocol. Please note, if your current procedure contains a 3D protocol, it is also possible to select the 3D protocol manually from the examination menu on the touch screen. 3D acquisitions are performed with the system positioned at the table, head, side, left side, or right side. To move the system to the starting position, press down on the left joystick and deflect the joystick away from you. The system moves to the start position for the 3D acquisition. When positioning the system, follow the guidance on the exam room display. Guidance messages appear for all steps of the acquisition workflow. It is a requirement for 3D acquisitions that the region of interest is positioned in the ISO center position, the region of interest in the center in the AP position. Perform fluoroscopy briefly using care position. Adjust the table longitudinally and transversely so that the region of interest is in the center of the field of view. To position the region of interest in the lateral position, press on the stand C arm joystick and deflect the joystick away from you. Perform fluoroscopy briefly using care position. Adjust the tabletop height so that the region of interest is in the ISO center. The optional laser cross might be of help during this step. When you are satisfied that the region of interest is positioned within the ISO center, you can continue with the 3D workflow and enter the test phase. To prepare, move the system to the start position for the test phase. Press on the Stand C arm joystick and deflect the joystick away from you. When the system is in the start position for the test phase, a message appears on the exam room display. It is important in the test phase to ensure that the area of rotation is free from possible collisions. Move any equipment away from the rotation zone, including the exam room display. To start the test phase, press down and deflect the left joystick away from you. The C arm will rotate around the region of interest. This test is performed at a slower speed than the later acquisition to allow a better reaction to possible required changes. Keep the joystick deflected. The test phase will end automatically. For automatic setting of acquisition parameters. You are prompted by the system at the end of the test phase to perform fluoroscopy. When the test phase is complete, the system is ready for acquisition. Before you start the 3D acquisition, ensure that you are prepared for the injection of contrast media if required. C arm rotation depends on the selected protocol. For example, in Dr. acquisitions, the system will perform 1C arm rotation. If an injector is armed, the contrast agent will be injected. DSA acquisitions will involve 3 rotations of the C arm, the mask run, the return rotation, no X-ray, and the fill run. The injector will be started for the fill run. The system will wait the time that is set in the X-ray delay. Some acquisition protocols involve a bolus watching phase after the mask run. For example, Dyna PBV neuro acquisition can be released by the hand switch or the foot switch. The contrast medium injection can be synced with the acquisition or you can manually trigger the injection of contrast media using the injector interface. During the 3D acquisition, as the C arm rotates around the region of interest, the 2D images are shown on the exam room and control room displays. This allows you to see the anatomical structures and monitor the injection of contrast media. Continue to release X-ray, hand switch or foot switch until you are notified by the system that the 3D run is completed. An audible signal indicates that the acquisition is complete. When the 3D acquisition is finalized, the 3D acquisition program is automatically deselected and a 2D acquisition program is selected by default. If configured, the system can be moved back to the working position prior to entering the 3D acquisition workflow.
4677843345 1% 120 20 ARTIS pheno 3D Acquisition ARTIS OK Store as Reference ... Store Monitor Ref follows C-Arm ... CLEARstent Pointer Save Bookmark Save Angulation Bookmark Hide All Objects Save Snapshot 3D Reconstruction ... Head & Neck Cardio Thorax High Contrast Vessel Tree Procedure Cardio Thorax Examination Display C-Arm Position RDMP & Overlay Case Flows Head & Neck Cardio Thorax Series Descr. Measure Field Scene Length 20 sec. Acquisition A+B Block X-Ray 3D Wizard Favorites Procedure Head & Neck Information 15 ml Step Overview 3D: Deflect joystick to move system to ISO 3:29 PM 0.0 mA 0.00 uGym2 AP position Back 0.0 ms 0.00 mGy CA kV mA ms 33 PM 0.0 kV Ref Image +/- A:3D test phase: Start fluoro to complete test phase Image +/- Pause Scene +/- Play DSA acquisition PATIENT, Siemens Healthineers Automatic run: Deflect joystick DSA 4 CNR (4.0 f/s) FL Neuro (10.0 p/s) 3:41 PM target position (X) Siemens Healthcare GmbH, 2020 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. The information in this material contains general technical descriptions of specifications and options as well as standard and optional features that do not always have to be present in individual cases. Certain products, product related claims or functionalities described in the material (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. SIEMENS Healthineers
- artis
- pheno
- ve20
- artispheno
- atris
- robotic
- c-arm
- angio
- angiography
- interventional
- surgery
- radiology
- 3d
- acquisition
- dynact
- dyna3d
- ve2
- ve20
- ve2x
- ve21
- ve3
- ve30
- ve3x
- artis ve2
- artis ve20
- artis ve2x
- artis ve21
- artis pheno ve2
- artis pheno ve20
- artis pheno ve2x
- artis pheno ve21
- artis ve3
- artis ve30
- artis ve3x
- artis pheno ve3
- artis pheno ve30
- artis pheno ve3x