
ARTIS pheno VE1 Safety Job Aid
This pdf introduces you to the safety component of your ARTIS pheno VE10 systems.
Target group: Basic user
Recommended to be viewed on the following devices: All (incl. tablet, smartphone)
SIEMENS Healthineers Safety Job Aid ARTIS pheno VE10 Template Effective Date: 05/27/2019 | HOOD05162003010284 Job Aid Effective Date: 01/31/2020 | HOOD05162003063487 Effective Date: 01/31/2020 | HOOD05162003063487 Effective Date: XX/XX/XXXX | HILS/HOOD# Unrestricted © Siemens Healthcare GmbH, 2020 Unrestricted © Siemens Healthineers, 2020 © Siemens Healthcare GmbH, 2018 Safety – SIEMENS Healthineers Table of Contents Emergency STOP buttons 3 Warning Signs 4 Danger Points 5 CPR Position 6 Power Failure – Rescuing Patient 7 Reset Unit Computer/ Collision Override 8 Brake Test 9 2 Effective Date: 01/31/2020 | HOOD05162003063487 Unrestricted © Siemens Healthineers, 2020 Safety – SIEMENS Healthineers Emergency STOP buttons In case of emergency, press one of the red Emergency STOP buttons immediately to shut down all system drives and stop unit movements and radiation. By pressing the footswitch you can release radiation again right away. In the following cases you should press the Emergency STOP button: If a malfunction of the system occurs. • STOP STOP If a unit movement causes an emergency situation involving danger to • the patient, to operating personnel, or to the unit. If unwanted radiation occurs, for example if a radiation release pedal • jams or it is blocked by a radiation protection lead rubber skirt. The Emergency STOP buttons are located on the front sides Canceling STOP: of the Table control module and the Pilot control module Only when you can identify the cause of the danger unequivocally and • remedy it can you then disengage the emergency STOP button. To do so, pull the red emergency STOP button. Movements are then possible again. 3 Effective Date: 01/31/2020 | HOOD05162003063487 Unrestricted © Siemens Healthineers, 2020 Safety – SIEMENS Healthineers Warning Signs Danger of crushing for the patient and/or operator. Maximum patient table load. (patient load + accessory load - without CPR load) Maximum patient table load, without accessory load and without CPR load. (CPR = Cardio-Pulmonary Resuscitation) Position of the tabletop for CPR: To achieve the maximum stability for a cardiac massage (CPR = cardiopulmonary resuscitation), move the tabletop so that it is directly above its supporting table column. 4 Effective Date: 01/31/2020 | HOOD05162003063487 Unrestricted © Siemens Healthineers, 2020 Safety – SIEMENS Healthineers Danger points Risk of collision and crushing at the following points on the stand and C-arm: • At all joints during rotations and movements • On the rails of the Flat Detector (FD) slide for FD lift 5 Effective Date: 01/31/2020 | HOOD05162003063487 Unrestricted © Siemens Healthineers, 2020 Safety – SIEMENS Healthineers Cardiopulmonary Resuscitation (CPR) position Move the system to the Cardiopulmonary Resuscitation (CPR) position: 1. The tabletop must not be tilted and the tabletop must be positioned so that the patient's thorax is positioned over the table column. This will ensure the maximum stability. 2. Press the CPR Assist key on the Pilot control module and keep it pressed until the movements stop. 3. Press knob/joystick down on the Pilot control module to position the tabletop above the supporting table column. Begin CPR when the tabletop is positioned over table column. 6 Effective Date: 01/31/2020 | HOOD05162003063487 Unrestricted © Siemens Healthineers, 2020 Safety – SIEMENS Healthineers Power Failure – Rescuing Patient In case of power failure and certain component failures, all motors of the ARTIS pheno stand are deenergized and all brakes engaged. You need to release the brakes manually. 1. Open the cover on the 2. Open the flap and take out 3. Pull the button on the 4. Move the stand/C-arm manually: rear of the stand base. the handheld. handheld to release the brakes • Rotate the C-arm so that there is room to and to move the system. release the patient. • Swivel the stand to clear space. Pull/push vigorously to overcome the weight of the C-arm. 6 • Press the button on the handheld to fasten the brakes again. 7 Effective Date: 01/31/2020 | HOOD05162003063487 Unrestricted © Siemens Healthineers, 2020 Safety – SIEMENS Healthineers Collision Override and Stand Control Unit (SCU) Reset Stand Control Unit Reset: If no unit movement is possible, even if Emergency STOP buttons, collision protection sensors and block movement have been checked, you can reset the unit computer: ? + STOP 1. Simultaneously press and hold the Help button and then push the Emergency STOP button on the Pilot control module. Wait until bypass screen appears on the exam room monitor. 2. Then pull the Emergency STOP button and after that release the Help button. The unit computer will be restarted and should be ready for operation after a short time. Collision Override: WARNING If a collision occurred and the collision sensor responded: When the safety override ? 1. You can initiate the movement by pressing and holding the Help button at Pilot is active, executing unit control module. The message Collision control deactivated appears. movements can result in a higher collision risk of 2. Deflect the operating element in one of the possible directions. mechanical damage or personal injury. 8 Effective Date: 01/31/2020 | HOOD05162003063487 Unrestricted © Siemens Healthineers, 2020 Safety – SIEMENS Healthineers Brake (Stand) Test The system requests a brake test regularly. You need to perform the brake test in the Parking position. 1. Select the Parking position in the System Positions under C-Arm Position menu on the touchscreen of the Pilot control module. 2. Touch and hold Hold to Drive. or – – PCM - touchscreen Press the stand/C-arm joystick away from you and deflect it forward until the Parking position has been reached. 3. Keep touching and holding Hold to Drive. or – – Pressing the stand/C-arm joystick down and deflect it away from you. The message Stand Test: Activate stand movement # s is displayed. The brake test starts and the message Stand Test: running is displayed. 4. The system performs the brake test for each axle (6 times). PCM - Stand/C-arm joystick 5. Continue pressing down and deflecting the joystick until the message Stand Test: Successfully completed is displayed. ntinue pressing down and deflecting the joystick until the message Stand Test: Successfully Normal movements are possible again. If the brake test is not successful, the message Automatic Stand Test failed, SC is completed is displayed. Normal movements are possible again. If the brake test is not successful, displayed. All movements of the stand are blocked. In this case please call Siemens Healthineers Service. the message Automatic Stand Test failed, SC is displayed. All movements of the stand are blocked. Please note: You can interrupt the brake test at any time by releasing the In this case please call Siemens Healthineers Service. Stand joystick. The message Stand Test: Will be aborted in # s is displayed. 9 Effective Date: 01/31/2020 | HOOD05162003063487 Unrestricted © Siemens Healthineers, 2020 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84 0 siemens.com/healthineers 10 Effective Date: 01/31/2020 | HOOD05162003063487 Unrestricted © Siemens Healthineers, 2020
- artis
- pheno
- artispheno
- pheno overview
- atris
- peno
- feno
- angio
- angiography
- interverntional
- Ve1
- ve10
- ve1x
- artis ve1
- artis ve10
- artis ve1x
- artis pheno ve1
- artis pheno ve10
- artis pheno ve1x