ARTIS one - Safety Job Aid
This pdf introduces you to the safety components of ARTIS one system.
SIEMENS Healthineers Safety Job Aid ARTIS one VA1x Template Effective Date: 10 Aug 2021 | HILS 2223 OUS Effective Date 01 APR 2022 | HOOD05162003265211 US Effective Date 06/17/2022 I HOOD05162003283804 Unrestricted © Siemens Healthineers, 2022 Safety SIEMENS Healthineers Table of Contents Emergency STOP Buttons 3 Warning Signs 4 CPR Position 5 Danger Points 6 Rescuing the Patient in the Event of a Power Failure 7 Footswitch Defect 8 Reset Unit Computer/Collision Override 9 Brake Test 10 2 Effective Date 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Safety SIEMENS Healthineers Emergency STOP Buttons Press the Emergency STOP Button In the event of danger, press one of the red emergency STOP buttons immediately to shut down all system drives and to stop unit movements and radiation. You can release radiation again right away by pressing the footswitch. -1 + In the following cases, you should press the emergency STOP button: STOP STOP • If a malfunction of the system occurs • If a unit movement causes an emergency involving danger to the STOP patient, operating personnel, or the unit If unwanted radiation occurs (e.g., if a radiation release pedal jams, or ARTIS one Stand Control Module • if it is blocked by a radiation protection lead rubber skirt) and Table Control Module (Front) Canceling STOP Only when you can identify the cause of the danger unequivocally and remedy it, can you then disengage the emergency STOP button. To do so, pull the red emergency STOP button. Movements are possible again. 3 Effective Date 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Safety SIEMENS Healthineers Warning Signs Danger of crushing for the patient and/or operator. + Maximum patient table load. ... kg (patient load + accessory load - without CPR load) Maximum patient table load, without accessory load, and without CPR load. max ... kg (CPR = cardiopulmonary resuscitation) CPR label: This warning label indicates the position of the tabletop for CPR. 4 Effective Date 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Safety SIEMENS Healthineers CPR Position To achieve the greatest stability for a cardiac massage Please note: (CPR = Cardiopulmonary Resuscitation), the tabletop The ARTIS one systems are designed for must be moved so that it is directly above its supporting cardiopulmonary resuscitation (CPR = cardiopulmonary table column. resuscitation) with a pressure compression of up to 600 N (60 kg). Moving to the CPR Position To move to the CPR position, position the tabletop above The maximum patient weight must not be exceeded. the supporting table column. Only begin CPR when the tabletop is positioned over the table column. SIEMENS Healthineers 5 Effective Date 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Safety SIEMENS Healthineers Danger Points Danger Points on the Floor Stand Danger of Crushing • At the pivot bearing of the C-arm during rotations • At the friction bearing of the C-arm during orbital movements • On the rails of the FD slide for FD lift Danger of Collision • At the outer edges of the C-arm • At the top of the FD lift Danger Points on the Patient Table Danger of Crushing • Between the tabletop and the table column • Between the tabletop and the accessory rails Danger of Collision 6 • On the outer edges of the table and on the accessory rails Effective Date 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Safety SIEMENS Healthineers Rescuing the Patient in the Event of a Power Failure In the event of a power failure, motorized system movements are not available. However, you can move parts of the system manually to 2 rescue the patient in the event of danger. SIEMENS Healthineers ARTIS one Manual Stand Movement 1. Unlock the floor stand by pressing the unlocking pushbutton (1) (located on the rear side of the floor stand). 2. Swivel the stand by applying sufficient force (2). Rotating the Patient Table 1 1. Press the table unlocking pedal (3). 2. Keep pressing the pedal and rotate the patient table. 3. Release the pedal. 4. Rotate the patient table back and forth slightly until you hear it engage. Moving the Tabletop If necessary, you can move the tabletop of the patient table manually 3 in the longitudinal and transverse directions. Pull or push with 7 adequate force to overcome the braking force. Effective Date 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Safety SIEMENS Healthineers Footswitch Defect If fluoroscopy is not possible by pressing the respective Please note: Only activate this function if the fluoroscopy footswitch, you can also release fluoroscopy by pressing release pedal on the footswitch does not work. the acquisition release button on the handswitch. Examination Task Card (Control Room) 1. Select Acquisition > Activate Fluoro on Handswitch 2. A confirmation dialog opens. Click Yes. in the main menu. Activate Fluoro on Handswitch Change of handswitch mode is only permitted , if fluoro release is not possible due to a footswitch failure. Patient Acquisition Options Help Please inform Customer Service about this problem. 13.10. Exam Set Editor 13.10 On activation: Change Password -Fluoro release will be restricted to handswitch only Reset Password -Acquistion will not be available via handswitch anymore O Set Anatomical Background The handswitch will be automatically reset to acquisition mode STUI Head Holder Mounted after shutdown of the system 10/4 Activate Fluoro on Handswitch 1:28: 33 F Do you really want to activate fluoro on handswitch? Yes No ................................................................ 8 Effective Date 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Safety SIEMENS Healthineers Reset Unit Computer/Collision Override Stand Control Unit Reset If no unit movement is possible, even if the emergency STOP buttons, collision protection sensors, and the Block Movement function have been checked, you can reset the unit computer: 1. Simultaneously press and hold the Store position, Set zero stop keys, and STOP push the emergency STOP button on the stand/C-arm control module. Wait until the bypass screen appears on the exam room monitor. 2. Then pull the emergency STOP button and after that release the Store position and Set zero stop keys. Collision Override If a collision has occurred, and the collision sensor has responded: WARNING 1. You can initiate a movement by pressing and holding the Store position and Set zero stop keys simultaneously. The message Collision control When the safety override is active, executing deactivated appears. unit movements can result in a higher collision risk involving mechanical damage or 2. Deflect the operating element in one of the possible directions. personal injury. 9 Effective Date 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Safety SIEMENS Healthineers Brake Test (1/2) The ARTIS one system requests a brake test regularly. The brake test must be performed in the parking position. 1. Select the System Positions key on the stand control module (SCM) and select Parking position. 144 System Positions Key 2. Press down the stand control joystick on the SCM and deflect it SCM: System Positions Key away from you until the parking position has been reached. The system drives to the parking position. The message Stand Test: Activate stand movement # s is displayed. 3. Press down the stand control joystick and deflect it away from you again. The brake test is started and the message Stand Test: running will display. SCM: Stand Control Joystick 10 Effective Date 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Safety SIEMENS Healthineers Brake Test (2/2) 4. The system performs the brake test for each axle (six times). 5. Continue pressing down and deflecting the joystick until the message Stand Test: Successfully completed is displayed. Normal movements are possible again. K 144 If the brake test is not successful, the message Automatic Stand Test failed, SC is displayed. All movements of the stand are blocked (table movements are still possible). In this case, please call the Siemens Healthineers Service. SCM: System Positions Key Please note: The brake test must be performed with no patient on the table and no additional loads. You can interrupt the brake test at any time by releasing the stand control joystick. The message Stand Test: Will be aborted in # s will display. 144 SCM: Stand Control Joystick 11 Effective Date 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 12 Effective Date 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022
- artis
- artis
- atris
- artsi
- interventional
- angio
- angiography
- safety
- one