Siemens Healthineers Academy

ARTIS one - Postprocessing Job Aid

This pdf demonstrates how to use the different postprocessing tools for the ARTIS one system.

SIEMENS Healthineers Postprocessing Job Aid ARTIS one VA1x Template Effective Date: 10 Aug 2021 | HILS 2223 OUS Effective Date 01 APR 2022 | HOOD05162003265211 US Effective Date 06/17/2022 I HOOD05162003283804 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Table of Contents Postprocessing Task Card: 3 • Postprocessing Main Menu 4 • Review Modes 5 • Image Review Controls 6 • Subtask Cards 7 Postprocessing Onscreen Menu 12 Changing/Correcting Patient Data 13 Rearranging Series/Scenes/Images 15 Patient Search 16 Manual Deletion of Patient Data 17 Automatic Deletion of Patient Data 18 Archiving/Exporting/Transferring Data 19 Effective Date: 01 APR 2022 | HOOD051620032652102 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Task Card Patient Transfer Edit View Image Options Help 1 IC ONE C116 RF5 15 H AX R-D TC IL_UNE_CITO_AS_ 10 (1) Postprocessing main menu El EAS 3 amination 1/1/1940 VA10D 141126 F 1/1/1940 (2) Control area 3/25/2015 HFS Scene 10:31:56 AM 3 - 75/89 (3) Patient information area CARD 15 f/s STOP 4.89 sec 4 (4) Image review controls PostProc (5) Subtask cards View Image DSA (6) Quick access area (7) Status area with system messages and Quant status icons R 5 (8) Image area Adjust Calib Tools 3D Viewer 1859 -O 2532 auto / 11 SM Cardio EE 11% 6 Cardio exLD DDO 50% cm 20 A D 99 0º / CAUD 30 WC 1859 WW 2532 7 3 8 2 Effective Date: 01 APR 2022 | HOOD05162003265210 3 Unrestricted © Siemens Healthineers, 2022 Unrstricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Task Card: Postprocessing Main Menu When you move your mouse to the top area of the screen, the Postprocessing main menu will be displayed with the following functions: Patient Transfer Edit View Image Options Help Patient Transfer Edit View Transfer Edit View Image Options Help View Image Options Image Options Help Options Help Help Exam Protocol Send to ... Zoom Contents and Index ... Close Patient Invert Gray Scale Maintenance. Acquisition Size Native End Session ... Register Num 0 Export to ... About Artis one ... Emergency .. Eject from DVD_R Shutter Max Fill Override Configuration Change Vessel / Catheter Contrast Message History Browser ... Set Replace Mask Num . Eject from ... Annotation Filming Layout .. Finalize Medium and Eject from DVD_R Image Text CLEARstent Auto Expose V Scene Timer Film Task Status. Local Job Status ... Ctrl+L v ECG Display Flip Horizontally Load Test Images Film Preview .. Network Job Status ... Ctrl+N Flip Vertically Store Service Image Expose Film Task Ctrl+P Loop All Scenes Copy To WinNIEA Copy to Film Sheet Import from Off-line. Review Mode ... Select All Export to Off-line ... Service Search Record Off-line Files Export Image As ... Search Selected .. Screenshot to USB Send To 3D .. 4 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Task Card: Review Modes Default Review Mode* View Image Options Help Default Review Mode X 1. In the Postprocessing main menu, select View > Review Mode. A dialog box Zoom Acquisition Size Unstored Fluoro / RDMP _oop opens with the available review modes. Shutter Stored Fluoro / RDMP 2. Select the required review mode for the available acquisition modes. Annotation CARD Loop 3. Confirm your selection by selecting Close. Image Text V Scene Timer DR /DSA Loop V Review Modes for Fluoroscopy/Roadmap ECG Display PERI Loop Loop All Scenes 3D MFH • LIH (last image hold): The last fluoroscopic/roadmap image frame is Review Mode ... displayed Hide Patient Information Close Help • Loop: A fluoroscopy scene is replayed continuously from the first to the last image frame Review Modes for Acquisitions • MFH (Max. Fill Hold): Once a scene has been loaded, the maximum fill image is displayed immediately • Loop: An acquisition is replayed continuously • Toggle: The scene is played continuously but, unlike Loop, the review direction is reversed after the last image frame (ping-pong effect) 5 *Default Review Mode requires the Fluoro Loop license for changing the Review modes for Fluoro/Rdmp. Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Task Card: Image Review Controls Scene Scene Directory Scene Filter the scene directory: Opens an overview display of the Scene DSA 4 f/s STOP Ref. Image • Scene: Only scenes (multiframes Store Monitor stored scenes/images/ reference + Ref. Image and single acquisitions): + Store Monitor images depending on the current SM + Ref. Image acquisitions and stored fluoro, Image Review filter selection. roadmaps Controls 144 Scene - / Scene + • Ref. Image: Only reference images 144 Ref - / Ref + • Store Monitor: Only secondarily stored images DR 10 f/s 10 f/s Changing the Review • + Ref. Image: Scenes and reference Frame Rate images • + Store Monitor: Scenes and stored Starting/stopping the Loop images (no reference images) DR 10 f/s 10 f/s Single Step: A looping scene can • SM + Ref. Image: Stored images be stopped and then reviewed and reference images frame by frame forward or backward. 6 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Task Card: Sub task Cards View Image DSA View Image Option Select All Annotation and Measurements Full-screen Zoom Delete Selected Annotation and Measurements Acquisition Size Invert HIH Shutter Native Scene Overview Flip Horizontally v Annotation Flip Vertically Image Text Scene Timer Zoom 88.88. Shutter ECG Display Shutter View Sub task Loop All Scenes Annotation Review Mode ... Image Text Card Invert Gray Scale Curved Distance Measurement Main Menu Scene Timer v ECG Display Zooming/Panning Context Menu Zoom to Acquisition Size Looping through All Scenes Effective Date: 01 APR 2022 | HOOD051620032652107 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Task Card: Sub task Cards View Image DSA Image Options Help Select All Annotation and Measurements CLEARStent * Invert Gray Scale Delete Selected Annotation and Measurements Native Invert R R R | A Flip Horizontally Max Fill Override Native Change Vessel / Catheter Contrast Flip Horizontally CLEARstent Flip Vertically R Flip Vertically Flip Horizontally Zoom opac Flip Vertically Shutter Image Sub task Annotation Card Opacification Select All opac Export Image As ... Image Text Curved Distance Measurement 000 Send To 3D. Scene Timer v ECG Display Main Menu Context Menu * CLEARStent is an option Effective Date: 01 APR 2022 | HOOD051620032652108 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Task Card: Sub task Cards View Image DSA + % Move Mask Averaging Mask/ Fill M + Image Native/Subtracted Zooming/Pan ning MI Anatomical Background Zoom to opac Acquisition Size DSA Sub task Card* Pixelshift Opacificati opac on Invert Gray Scale *The DSA subtask card is an option. 9 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Task Card: Sub task Cards Adjust Calib. Tools 2100 Windowing Adjust Calib. Tools Auto ISO Calibration 1695 2250 Set brightness and auto Isocenter calibration is 2400 auto D'- contrast auto auto automatically preselected by -O- -!- Auto Window the system for image angle 50° auto 130°. ... 20 Auto TOD Calibration Window Home TOD calibration is auto Adjust Sub task M 21 Edge Enhancement Calibration Subtask automatically preselected by Card Card the system for image angle 0° 50° or 130° ... 180°. ... n Edge Enhancement Home -!- Manual Distance Calibration Once the distance line has been drawn by moving and marking with the mouse pointer, the length of the distance line is entered, and calibration is applied. 10 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Task Card: Sub task Cards Adjust Calibr. Tools XYZ Annotation: Enter ..................................... text in the image Drawing Line XYZ ................... .. Drawing Circle Pointer: Point out certain image details on the screen Drawing Polygon Distance: The distance between two points of a straight distance line or along Tools Sub task Card a curve Hide Annotations and Angle: Angle measurement by drawing two lines Measurements Drawing Arrow 11 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Onscreen Menu The Postprocessing Onscreen Menu contains the functions depending on the Onscreen Menu configuration. AX R-D VA General Native Sensis MPR VRT General DSA VRT MPR Workflow General Native Correct in the main menu of the 2. Select Edit > Correct in the menu of the Patient Postprocessing task card. 1 Patient Browser Browser. or – Patient Transfer Edit View Filter Sort Private Applications Optic – Press the Patient Browser (Num .) key on the symbol keypad. 7 Patient Browser (Num .) Key Please note: It is not possible to correct or rearrange The Patient Browser window opens. Select the patient patient data for the following cases: requiring the modification. Corrections depend on the • Specific data of special objects, for example, selected level in the Patient Browser: Patient - Study - patient position in the Exam Protocol SR Series - Instance. Studies that include only one scene • Protected data should be corrected on the Instance level. Only data • Data of HIS/RIS patients that refers to the selected level can be modified. To • Data of the current examination patient during modify the name of the series (scene name), for radiation example, the Series level must be selected. • Data on external media 13 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Changing/Correcting Patient Data continued 3. The Correct window opens. Select 4. To correct the patient position, 5. After correcting the patient data, the Patient sub task card and enter select the Series sub task card and enter your name under Modifier's the correct patient data. If select the correct position from the name or select your name from the necessary, change other data. drop-down list. selection list and select OK. Modifier's name meduser Modifier'S name meduser Modifier's fuime meduser Last name' 14 03 13-02 55-11-51C Fust name Lest parn 14 03 13-02 55-11.STC Fust name Patient D 14 03.13-02 55:11-STD-81993 Middle name Patient D 14:03.13-02 55:11-STD-81993 Middle name Modifier's name |meduser Title Patient Sum Surt Lost pme 14 03 13-02 55-11.5TC Fust name Patient D 14 03.13-02 55:11-STD-81993 Middle name Patient Referring physician Other patients name(s) Other patients name(s) Admission D Other patient D(s) Referring physician Admission D Other patient D(s) Ethnic group Ethnic group Referring physician Other patients name(s) Matary rank Matary rank Admission D Other patient D(s) Date of birth 1/1/1900 Date of birth 1/1/1900 Ethnic group Accession No Sin w Male Accession No Matary rank Fermato Sun a Male Fermate Date of birth 1/1/1900 Helgly Helgly Sur @ Male Fermato Weight Weight Senwe descoption Address Senwe description Address Weight Swies date Senwe descrption Address Addisonal into Addisonal into Swhen date Addisonal into Nurrant Comment Comment Comment OK Cancel Hoio OK Cancel Hoio OK Cancel Holo 14 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Rearrange Series/Scenes/Images 1. Call up the Patient Browser by pressing the Patient Browser (Num .) key on the Rearrange symbol keypad. "14.03.13-02:55:11-STD" on "Local" 1 Study, 24 Series (total 23 Images, 0 NonImages, 0 Waveforms, 0 RT Objects, 1 Report/Result Object, 0 new Patient Browser (Num .) Key DICOM Objects, 0 RawData, 0 SurfaceSegmentation(s). 0 Encapsulated Document PDFs) will be moved to Patient 14.03.13-05:20:36-STD 2. Select the series/scenes (images). Modifier's name meduser 3. Drag and drop: Drag the selected data to the target position and release the mouse OK Cancel Help button. or – – Cut and paste: Click this icon or call up Edit > Cut in the menu of the Patient Browser. 4. Click the target position. 5. Click this icon or call up Edit > Paste in the menu of the Patient Browser. 6. The Rearrange dialog box will be displayed. 7. Enter your name under Modifier's name or select your name from the selection list. 8. Confirm by clicking OK. Please note: Rearrange is not possible in the following cases: • Rearranging to the wrong data level • Rearranging scenes/images to a series acquired with another patient position 15 • If images were acquired on a different modality (e.g., CT) Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Patient Search Using the Patient Search, you can query and retrieve patient and Patient Search X Basic Search Node examination data from workstations and long-term archives that work Patient Name From To Patient ID Study Date Artis_Qceiling Date of Birth Study Time Artis QzenBP SENSIS Hemo with other DICOM program systems. Sex Any Accession Number XWP Qbiplane IXWP Qceiling Modality Advanced Search Study Description From To 1. Click this icon in the toolbar. Study ID PPS Start Date Referring Physician PPS Start Time or – Reporting Physician Body Part Exam – Study Instance UID Performing Physician Select Patient > Search... in the menu of the Patient Browser. Series Instance UID Request Procedure ID Series Number Scheduled Procedure ID The Patient Search window opens. Series Description Approval Status Reporting Search 2. Enter your search criteria and click Search. Search Clear Type New Query Name Save Delete If you want to search for an existing patient in the Local Database Import Import Job Status Image List Discard search results on close Close Help folder in the network: Ready 1. Select a patient in the Patient Browser. 2. Select Patient > Search Selected... in the menu of the Patient Browser. The Patient Search window is displayed. 3. Enter your search criteria and select Search. 16 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Manual Deletion of Patient Data 1. Call up the Patient Browser by pressing the Patient Browser (Num .) key on the symbol keypad. Patient Browser (Num .) Key 2. Select the objects to be deleted via a single LMB click. 3. Select Edit > Delete in the menu of the Patient Browser or open the context menu (right mouse button) and select Delete there. or – – X Click this icon in the toolbar. A dialog box appears in which you must confirm that you really want to delete the data you have selected. 4. Confirm the question with Yes to delete the selected patient and examination data. 17 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Automatic Deletion of Patient Data AutoDelete Configuration Local RawData Recycle Bin 1. Select Options > Configuration... in the main menu. Automatic deletion is performed at following timepoints for following data Deletion can also be started manually via the menu 2. Double-click the Auto Delete icon. i (Edit > Auto Delete) Do not permanently delete data. Move data to recyclebin Auto Delete Icon Timepoints for deletion If database fillstate has reached 80 % The Auto Delete Configuration window opens. or Monthly Select whether the recycle bin should be used or not. Select the Do not 00-8 o Day of even month(s) permanently delete data. Move data to the recycle bin check box to O The sunday of every month(s) change the setting. Data to be deleted 3. Select the database (local database or recycle bin) for which automatic Delete all series with following flags [ Archived deletion shall be configured. [ Archived + Committed [ Sent 4. Define the Timepoints for deletion. Select the options to be used. Sent + Committed or 5. Define the Data to be deleted. Select the rules to be used. Delete all studies which are older than 14 day(s) 6. Define Ask confirmation before deletion. If this option is selected, users Ask confirmation before deletion OK Cance Help are prompted to confirm whether data should be deleted when Auto Delete starts. 7. Click OK to apply the settings. 18 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Archiving/Exporting/Transferring Data Archive To and Send To 1. Setting a Directory Filter 2. Displaying the Scene Directory 3. Archiving/Sending In the Postprocessing In the PostProc or Quant task card, click the Scene Click this icon in the Patient task card, select the Directory icon. Browser. required display from the drop-down menu. Scene Directory Icon The system switches to 4 x 4 display mode and or – – displays the representative image of each stored Scene - + scene. Select Transfer > Send To... or To select all objects: Transfer > Archive To... in the Scene Scene Select Image > Select All in the main menu. main menu. Ref. Image Store Monitor or – – + Ref. Image + Store Monitor Press Ctrl + A. You will see this icon SM + Ref. Image All To select the required scenes/images: at the bottom of the control Select one of the required images. Press the Ctrl area. key and select the additional scenes/images. Data is being sent. 19 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Archiving/Exporting/Transferring Data Exporting to CD-R/DVD 1. Insert an (empty) CD-R/DVD into the writer. The first time you export data to a new medium, the Enter Label dialog box is displayed. Enter a unique name for the medium. 2. Select this icon in the Patient Browser. or – – Select Transfer > Export To... in the main menu. A dialog box with the available archiving destinations opens. 3. Select one or more destinations and click Export/Archive. The image data will be archived at the selected destinations. 20 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Archiving/Exporting/Transferring Data Automatic Sending/Transfer Configuration ransfer Configuration X Auto-Transfer Local Devices A Workstate Processing Status Objects Destination MP Completed Don't care mages New You can configure destinations for sending and exporting and set up Delete automatic sending/exporting. Automatic sending should only be set for syngo products. To open the automatic sending/transfer configuration panel: 1. Select Options > Configuration... in the main menu. 2. Double-click the Transfer Configuration button. Activate transfer rule Marked images only Printed images only Transfer Configuration Button Completed Don't care Images to None Images Transfer None Don't care Don't care Non Images Reports Completed Archived Series 3. Select New to create a new transfer rule. Read Archived & Committed Studies Verified Archived & Verified Received Waveforms Sent Sent & Committed Structure Set 4. After creating, select Active transfer rule to activate your transfer rule. Printed RT Plan Exported OK Cancel Default Help 5. Always select Don't care in the second drop-down menu. Otherwise, the transfer rules will not work. 6. Select OK. Please note: • An auto transfer rule consisting of Don't care + Received + Series or Studies will not result in an auto transfer. Set Don't care + Received + Images as an auto transfer rule. Most cardiac networks and viewing stations only permit processing/viewing with 512²/8-bit image display. • 21 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Archiving/Exporting/Transferring Data Exporting Scenes/Images Export Image As ... ? X 1. Select Image > Export Image As... in the main menu of the Format Format Type AVI PostProc task card. The Export Image As window appears. Type AVI AVI Range 2. Select the desired format from the Type selection list. Bitmap Fron 33 To 44 Select All JPEG E 3. Select the range (if applicable). Settings Full Frames (Uncompressed) Change 4. Select planes (if applicable). Image Options Help Output Size: 1024 x 1024 Plane: A+B 5. Set the image matrix. Invert Gray Scale Include: M Text M Graphics D ECG Native Path And File Name 6. Include or do not include text/graphics/ECG. Max Fill Override HA\CDR_OFFLINE 7. Define the file for the data. The export location is set automatically ICStent AX_Angio_(S3_11_F33-44)A.avi AX_Angio_(S3_12_F33-44)B.avi when the USB device is plugged in. Flip Horizontally 8. Start the export by selecting OK. Flip Vertically Export Progress: Please note: Export Image AS ... Record Off-line Files Scenes/images can be exported in a common format to a directory on an Send To 3D ... OK Cancel Help external USB device. The following image formats are supported: • AVI format (*.avi): Various video compression codecs are supported. • Windows Bitmap (*.bmp) • JPEG format (*.jpg) 22 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022 Postprocessing – SIEMENS Healthineers Archiving/Exporting/Transferring Data Exporting Image Data to an External USB Device Patient Transfer Edit View Image Options Help IC_ONE_C116_RF5_15 H AX R-D TC Examination EAS 1/1/1940 VA10D 141126 1/1/1940 1. Plug the USB device into the USB jack. 3/25/2015 HFS Scene 10:31:56 AM 3 - 75/89 2. Wait a moment (until the LED on the drive stops blinking). CARD 15 f/s STOP 4.89 sec PostProc Removing the USB Device View | Image DSA 4. Single-click the LMB on this icon in the status area. Quant 5. Left-click Safety Eject PNP Device to remove your external R USB device safely. Adjust | Calib. Tools 3D Viewer 1859 2532 auto 6. The USB device can be unplugged following the status -O message PNP device can be unplugged in the status area. JV Please note: SM Cardio Cardio exLD 5 11% DDO 50% If you remove the USB device without deactivating it via the cm 20 A D 99 0º / CAUD 30€ WC 1859 software, this may result in data loss, damage to the WW 2532 operating system and damage to the media. Do not immediately unplug a USB device. Always use the software PNP Device Mounted - Drive(F:): Tot ... functionality for safe removal before unplugging. 23 Effective Date: 01 APR 2022 | HOOD05162003265210 23 Unrestricted © Siemens Healthineers, 2022 Unrstricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 24 Effective Date: 01 APR 2022 | HOOD05162003265210 Unrestricted © Siemens Healthineers, 2022

  • artis
  • artis
  • atris
  • artsi
  • interventional
  • angio
  • angiography
  • postprocessing
  • one