
ARTIS icono ceiling VE23 - System Operation Job Aid
This pdf demonstrates how to perform the daily system operations tasks at the ARTIS icono ceiling VE23 system.
SIEMENS Healthineers System Operation Job Aid ARTIS icono ceiling VE23 Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: 23 AUG 2022| HOOD05162003288213 Effective Date: XX/XX/XXXX | HILS/HOOD# Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 Unrestricted © Siemens Healthineers, 2020 © Siemens Healthcare GmbH, 2018 System Operation SIEMENS Healthineers Table of Contents Switching On/Off 3 Control Modules – Overview 5 Control Modules – Table Control Module (TCM) 6 Control Modules – Pilot Control Module (PCM) 7 Membrane Keys on the Flat Detector (FD) 17 Layout Gallery 18 2 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Switching On/Off Switching the system on 1. To start the system, press and hold the Power-on button on the 2. The system performs a self-test and is started up. CPC for approximately 0.5 seconds. 3. BYPASS is displayed until the Welcome screen is displayed in the examination room. Welcome! SIEMENS Your patient Patient Demo (2/14/1943, Male) has been positioned Head First Supine. The procedure Coronary has been selected. This screen will disappear after first X-ray. Please ensure that the on-site main switch is switched on and the Emergency Shutdown button is inactive. 4 Patient Rescue esuscitation Position Manual Unlock Table Emergency Stop Emergency Collision Override 4. All functions are now available. 3 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Switching On/Off Access the Home screen by clicking the Home button in the Info area. Click on the arrow below the Shutdown button. Switching the system off 1. Select Shut down System. A dialog box is displayed. 2. Click Yes or No to continue. Examination System Messages Lock • If you click No, you will return to the Home screen. • If you click Yes, the system will shut down. Open workflows will be closed, and results will be saved. Restart System Shut down System G Restarting the system 1. Select Restart System. A dialog box opens. 2. To restart the image evaluation system, click Confirm. The image evaluation system in the control room is shut down and started up again. 4 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Control Modules – Overview Table-side controls allow you to operate the stand, patient table and imaging system. ARTIS Examination C-Arm Position ROMP & Overlay OK Case Flows Tools Favorita 63 B ❶ ❷ ❸ ❶ Table control module (TCM) ❷ Pilot control module (PCM) ❸ Collimator control module (CCM) 5 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Control Modules – Table Control Module (TCM) Knob with floating tabletop (with or without servo assistance) Table Panning knob for servo- 4 Table lift up/down assisted tabletop movement ( TCM-S) Adjust the tabletop position. Block table movements LED lights up white when the table is not blocked. TOP LED lights up blue when the table is blocked. LED flashes blue when block all movements has been enabled. Joystick for motoric Unlock table rotation for multi-tilt table only tabletop movement (TCM- LED lights up white when table rotation is not active. J): Adjust the tabletop C- LED lights up blue when table rotation is active. position. Orientation of control module - STOP The blue LED indicates the selected orientation (indication on top of the control module, key on the underside of the control module) 6 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Control Modules – Pilot Control Module (PCM) Monoplane 1 2 4 3 ARTYS MT - 5 Stand/C-arm joystick 1 2 2 Stand/C-arm joystick 2 STOP 6 3 Jog wheel 4 Touchscreen 5 Keys on top and on the front of the control module 6 Emergency STOP button 7 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Control Modules – Pilot Control Module (PCM) General functions Block all stand/C-arm and Store direct position CA Drive to home C-arm position table movements: LED lights up blue while table + movements are blocked. G G G Drive to direct position 1/2/3 Stop 0-position: Make system stop in basic position Block radiation: LED lights Increase/decrease image quality up blue while radiation is (increase dose) during fluoroscopy Define as ROI: Sets the isocenter blocked. Reference image directory Drive to CPR position Use stop watch Scene directory Onscreen menu - Layout selection Exit function X OK button: OK Confirm action 8 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Control Modules – Pilot Control Module (PCM) Monoplane 1 Store reference image to Ref 1/2 RE 5 Angulate C-arm 5 depending on configuration 4 G G 6 2 Store Monitor or Store Fluoro 6 Move C-arm horizontally depending on configuration 3 Increase/Decrease zoom stage 1 2 OK = 3 4 Couple with Table: Synchronize C- arm movement with table movement 9 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Control Modules – Pilot Control Module (PCM) Pilot touchscreen - table movements ARTIS Height: Adjust table height. Couple with table: Maintain relative position and angle of patient table and C-arm. Tilt: Tilt the tabletop in Trendelenburg or Examination Display reverse Trendelenburg direction. Block table: Block all table movements. C-Arm Position Table Cradle: Tilt the tabletop laterally. Unlock rotation: Unlock table rotation. Detector RDMP & Overlay Transversal: Move the tabletop transversally. Block transversal: Block transversal tabletop movements, move tabletop longitudinally. Case Flows Tools Longitudinal: Move the tabletop longitudinally. Favorites Define as ROI: Set the current position as the isocenter. H Sys. Pos. Case Flows Display Exam Favorites 10 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Control Modules – Pilot Control Module (PCM) Pilot touchscreen - detector movements ARTIS Rotation: Rotates the FD. Rotates the FD clockwise Examination Display Rotates the FD counterclockwise C-Arm Position Table O O Rotates the FD back to automatic FD/collimator rotation Detector RDMP & Overlay Case Flows Tools + Zoom: Selects the zoom stage/input + format. Favorites Lift: Changes the source to image distance (SID). H Sys. Pos. Case Flows Display Exam Favorites ... ... ....... Laser Light: Switches the laser light on or off. 11 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Control Modules – Pilot Control Module (PCM) Pilot touchscreen – C-arm position Selecting a programmed position 1) Tap C-Arm Position in the main menu 2) Tap the required position menu to 3) Tap the required position, scroll the menu if necessary. on the touchscreen of the PCM. open the respective submenu. 1 |System Positions Current Positions Current Positions Switch Card / Angio Couple C-Arm A+B Home C-Arm ARTIS System Positions Patient Transfer REF 1 +C Adjust C-Arm to Ref1 A Couple with Table System Positions Head Side REF2 Adjust C-Arm to Ref2 A Couple C-Arm A+B Examination Display Biplane Head Side REF1 Adjust C-Arm to Ref1 B FC +0+ Stop 0-Position G Anatom. Positions + Left Side REF2 Adjust C-Arm to Ref2 B C-Arm Position Table Biplane Left Side +0+ Stop 0-Position Direct Positions V * Sys. Pos. Case Flows Display Exam Favorites Sys. Pos. Roadmap Display Exam Favorites Sys. Pos. Case Flows Display Exam Favorites Detector RDMP & Overlay Current Positions System Positions Direct Positions Anatom. Positio ... Left Side Direct Position 1 12 Case Flows Tools Left Side Biplane Left Side Direct Position 2 +. 14 Right Side, Table Rotated Direct Position 3 16 Biplane Left Side Peri Position 17 Favorites OR Position 18 H Sys. Pos. Parking Position 19 Sys. Pos. Case Flows Display Exam Favorites Case Flows Display Exam Favorites G Sys. Pos. Case Flows Display Exam Favorites Sys. Pos. Case Flows Display Exam Favorites Sys. Pos. Case Flows Display Exam Favorites 12 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Control Modules – Pilot Control Module (PCM) Pilot touchscreen – C-arm position Driving the stand to a programmed position Cancel Auto Drive × 1. After you have selected a programmed position on the touchscreen of the Pilot control module, the following message is displayed: Automatic run: Patient Transfer Activate stand movement. 2. Press and hold Hold to Drive. or – Hold to Drive – Press the Stand/C-arm joystick down and deflect it away from you until the target position has been reached. Head Side or – – If hands free movement is configured: Press the configured hands free Biplane Head Side pedal on the footswitch. H 4. The system performs the required movements. The following message is Sys. Pos. Case Flows Display Exam Favorites displayed: Automatic run: Position reached. 13 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Control Modules – Pilot Control Module (PCM) Pilot touchscreen – C-Arm position Store programmed position You can store any positions of the stand as Direct Positions, Anatomical Positions, or additional System Positions. Then you can initiate a programmed movement to such a stored position. 1. Move the unit to the required position. System Positions Direct Positions Anatom. Positio ... Save Position 2. Set the primary collimator and the filter diaphragms. OR Position Direct Position 1 + 12 3. Tap C-Arm Position in the main menu and the required position menu. Parking Position Direct Position 2 4. 14 4. Tap the Save icon in the upper right corner. The list of 11 Direct Position 3 16 Do you really want to save the stored positions is shown on the touchscreen. 13 17 position? 5. Select the free memory position or required position. 15 18 No The current position is stored under the selected 19 Yes memory position. The previous position is deleted. [ ............................... ] H Sys. Pos. Case Flows Display Exam Favorites Sys. Pos. Case Flows Display Exam Favorites 14 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Control Modules – Pilot Control Module (PCM) Pilot touchscreen – editing Favorites 1. Open the submenu to edit. ARTIS Editing Mode 2. To start editing: Press and hold on the touchscreen. To rearrange items: H Transversal * • :::: Examination Display Drag and drop the required item to the desired position. Longitudinal :::: To add an item to the Favorites: • C-Arm Position Table Touch the star A next to the desired item. Define as ROI To remove an item from the Favorites: RDMP & Overlay • Detector Couple with Table :::: Touch the star * next to the desired item. Case Flows Tools Block Table :::: Unlock Rotation Favorites :::: = Block Transversal * :::: Sys. Pos. Case Flows Display Exam Favorites 15 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Control Modules – Pilot Control Module (PCM) Pilot touchscreen – changing the view You can change the view of the touchscreen submenus for Tools and Roadmap. 1. Tap the menu icon at top right. 2. Select the required view. Tools Tools List View ... Icon View Native a) Icon view b) List view Invert Tools Roadmap Tool Roadmap Zoom by Factor 2 Display Mode Native Roadmap tive Invert Zoom Roadmap Subtr, Fluoro DSA ROMP Override Reset Invert Subtracted Fluoro Mix Fill Ove Max Fill Override 30 3D Display % X2 Zoom by Factor 2 DSA RDMP 3D Review Comrise Zoom A Zoom B 3D Review 20 Tools Max Fill Override Reset Roadmap A+B 20 Review Native Progress 3D Review Reset Roadmap A 2D Review OR 2D Review Reset Roadmap B V 16 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Membrane Keys on the Flat Detector (FD) SIEMENS Healthineers C-arm rotation Laser positioner light on/off (cran/caud angulations) (optional) C-arm orbital movement FD rotation (RAO/LAO angulations) (setting portrait/landscape) ............... -> -> Longitudinal C-arm movement FD lifting and lowering setting the SID - 17 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Layout Gallery Select the layout in the exam room 1 ① Layout Gallery ② Touchscreen 2 1. Press the Layout Gallery key. 1. Tap Display in the main menu of or – the touchscreen. – = 2. Choose General > Layout Gallery in the onscreen 2. Tap Layout and select the required menu (if configured). layout. Display 3. Deflect the jog wheel to select a layout. 3. To change the image source for Layout Default La ... 4. Press the OK button on the jog wheel to activate a individual segments, tap Source # Source 1 layout. and select the required image Source 2 source. Display Layouts UM Layout 01 Test Kelly Layout 02 Layout 03 KO Sys. Pos. Case Flows Display Exam Favorites 18 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 System Operation SIEMENS Healthineers Layout Gallery Select the layout in the control room In the control room, the Layout Gallery shows all the configured layouts for the image area. 1. Click the Layout Gallery icon in the Info area to Layout Gallery ? BX open it. Control Room Exam Room 2. Select either Control Room or Exam Room, depending on where you want to change the layout. Uni Box 1 Uni Box 2 Uni Box W ... Uni Box W Invalid Invalid Live Ref1 Ref2 3D Sharing DVI 1 Uni Box W ... Freestyle Table In 1 3. Click on the applicable layout option to select it. Ext 1 to 8 Default Layout f None None Viewer1 Uni Box 2 Uni Box 1 Live Ref1 Viewer1 Viewer2 None External Layout Basic Viewer Layout 19 Effective Date: 23 AUG 2022| HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 20 Effective Date: DD MMM YYYY| HILS/HOOD# Unrestricted © Siemens Healthineers, 2022
- artis
- icono
- artisicono
- icon
- ceiling
- interventional
- cardiology
- card
- radiology