
ARTIS icono ceiling VE23 - Safety Job Aid
This pdf introduces you to the safety components of the ARTIS icono ceiling VE23 system.
SIEMENS Healthineers Safety Job Aid ARTIS icono ceiling VE23 Template Effective Date: 05/27/2019 | HOOD05162003010284 Job Aid Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Safety SIEMENS Healthineers Table of Contents Emergency STOP Buttons 3 Warning Signs 4 Stand Control Unit Reset / Collision Override 5 Power Failure 6 Brake Test 7 2 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 Safety SIEMENS Healthineers Emergency STOP buttons In the event of danger, press one of the red emergency STOP buttons immediately. STOP ARTIS • All system drives are shut down and movements are stopped. • Radiation is interrupted, and fluoroscopy and acquisition are STOP STOP stopped. • If the injector is controlled by the system, injections are also The Emergency STOP buttons are on the front sides of the stopped. Table and Pilot control modules. Fluoroscopy and acquisition can be released again without cancelling the emergency stop, but system movements will only be possible after cancellation of the emergency stop. To cancel the emergency stop, pull on the button. 3 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 Safety SIEMENS Healthineers Warning Signs Do not look directly into the light beam for a lengthy time. HAZARD LEVEL 1M LASER RADIATION DO NOT VIEW DIRECTLY WITH Avoid directing the beam into the eyes of a trauma or anesthesia patient. NON-ATTENUATING OPTICAL INSTRUMENTS Danger of crushing for the patient and/or examiner. Maximum patient load, without accessory load and without CPR load. max ... kg (CPR = Cardio-Pulmonary Resuscitation) Maximum patient table load. .. . kg (patient load + accessory load - without CPR load) 4 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 Safety SIEMENS Healthineers Stand Control Unit Reset/Collision Override Stand control unit reset 1. Press the key and then press the Emergency STOP button on Ca the Pilot control module. Ca OK 2. If you pull the Emergency STOP button out again, unit movements are possible again. ta C + Collision override STOP STOP Pilot control module 1. If a collision occurs, press and hold the key on the Pilot control module and deflect the corresponding joystick simultaneously. The message Collision detection manually disabled - Move carefully A CAUTION appears. 2. Deflect the operating element in one of the possible directions. Higher risk of collision Risk of mechanical damage or personal injury!! 5 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 Safety SIEMENS Healthineers Power Failure In the event of a system or power failure blocking system movements with ARTIS, you can rescue or release the patient with the following steps: Move the system manually Rotate the table manually 1. Press the emergency STOP Standard table or multi-tilt table button. Press the table unlocking pedal and 2. Push the top stand by rotate the patient table slightly. applying sufficient force. Multi-tilt table Press the grip for rotating the patient table (available on both sides of the patient table). 6 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 Safety SIEMENS Healthineers Brake Test The system requests a brake test regularly at configurable time intervals. The brake test must be performed in the parking position, with no patient on the table and no additional loads. 1. Tap C-Arm Position > System Positions > Parking Position in the main menu of the touchscreen on the Pilot control module. ARTIS G Display 2. Press the stand/C-arm joystick down and deflect it away from you wamination C. Totale and hold it until the parking position is reached. The message Detectar RAF & Oveday Stand Test: Deflect joystick to perform stand test # s is displayed. OK Case flow Tools Favorites 3. Press the stand/C-arm joystick down and deflect it away from you 4 and hold it. The brake test is started and the message Stand Test: running... is displayed. Pilot control module If no brake test has been performed in the configured time interval, the message Stand test necessary within # days will appear. After this time has expired, the stand speed will be reduced. The message Reduced stand/table speed, Stand Test necessary will appear. 7 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2020 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 8 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022
- artis
- icono
- artisicono
- icon
- ceiling
- interventional
- cardiology
- card
- radiology