
ARTIS icono ceiling VE23 - Postprocessing Job Aid
This pdf demonstrates how to perform postprocessing steps at the ARTIS icono ceiling VE23 system.
SIEMENS Healthineers Postprocessing Job Aid ARTIS icono ceiling VE23 Template Effective Date: 05/27/2019 | HOOD05162003010284 Job Aid Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Table of Contents Segment Header 3 Loading Patient Data 5 Reviewing Scenes/Images 7 Postprocessing Scenes/Images 8 Default Review and Display Mode 13 Correcting Patient Data 14 DICOM Query/Retrieve 15 Archiving/Exporting/Transferring Data 16 2 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Segment Header Segment type You can load images to the Live, 3D Sharing or Viewer segments from the current examination or from previous examinations. The type of image that you can open in a segment depends on the segment type. Segment type Segment header Color Displayed image Live Live A Plane A: bright blue Current live image or LIH (last image hold)(examination patient) Reference Ref1 A Plane A: dark blue Reference image (examination patient) Viewer 1 Viewer 1 Green Images of integrated applications, for example 3D (review patient) Viewer 2 Viewer 2 3D Sharing 3D Sharing Bright green 3D/4D rendered images (examination patient / registered volume) Parallel Patient Red If images of another patient are loaded, the selected segment type switches to red External Sensis Gray Other video sources, for example Sensis Vibe or ultrasound, that may be connected to the display and configured as segments 3 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Segment Header The selected segment type is Favorites Other Options marked with a checkmark. You can add favorites (icons) to the segment header Live A by right-clicking and selecting Add to favorites in the Source Browser Sullings Live A Q Trowsur Sollings context menu. Live A To remove favorites, right-click and select Remove in Q Patient Browser Ref1 A the context menu. Image Directory Live E O Source Browser Settings Menu Windowing Zoom/Pan Store Ref Store Ref2 Store M ... E Segment Menu Segment Settings 4 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Loading patient data Live In the Live segment you can only load images from the current patient. This includes images from the current examination and previous examinations. You cannot load images from another patient to the Live segment. 3D Sharing The images displayed in 3D Sharing in the control room are synced with the 3D Sharing segment on the exam room display. You can load 3D images from the current examination or from a previous examination to 3D Sharing. Additionally, you can load a 2D secondary capture image of a 3D image in 3D Sharing. Viewer The Viewer is seen in the control room only. You can load all image types to the Viewer (2D Angiograms and 3D Volume images). You can load images from the current patient or images from another patient. It is not possible to load 3D images from the current examination to the Viewer. Further rules • Maximum of two different patients in parallel • Maximum of two 2D images at the same time • Maximum of two 3D images at the same time 5 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Loading patient data Loading scenes/images in the Patient Browser Loading scenes/images in the Image Directory 1. Click a segment. The active segment is marked by a 1. Open the Image Directory in the control room by bold frame. clicking the Images icon in the segment header. 2. Change the segment type, if necessary. or – – Open the Patient Browser by pressing the Patient R Open the Image Directory in the examination room by 3. Browser key on the keyboard. pressing this button on the Pilot control module. or – – Q 2. Select the study from the Select 4/19/2013, DSA-I.v.DSA/Dyna-CT 4. On the Segment menu, click the Patient Browser icon. Study dropdown list (default is Select Study 5. Select the required patient/study, the required 2D current examination). series, and double-click to load it into the segment. 3. Double-click the required image. The scene/image is selected and displayed in the active segment. 6 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Reviewing Scenes/Images Keyboard Review controls (player) Scroll series/scene backward You can stop a scene at any time, scroll forward or backward by one image, or resume reviewing. When a scene is loaded, the review controls are displayed at the bottom of the image. Scroll series/scene backward H Scroll image/frame backward FLUORO 15 14 1 Select previous/next scene/image. Scroll series/scene forward Scene Right-click/long press for setting the filter. 2 Select previous/next frame in the scene. Jog wheel Start/stop replay. The possible directions for jog wheel deflections and the corresponding functions are shown on the display in the For reference images, it is only possible to display the examination room. previous/next reference image. OK Image +/- Scene +/- Play Ref Image +/- Pause 7 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Scenes/Images E On the DSA tab of the Segment Menu, you can find various tools for adjusting the view of a scene/image which is displayed as subtracted. Segment Menu Live A ? GX Moving/replacing the mask + (Configure Move Mask or Replace Mask) Inverting grayscale values DSA D Move Anatomical Image Mask Blackgun Displaying a scene as native Averaging Measurement Pixel Shift % Fading anatomical background in/out Opacification Integrate the Annotation frames of the fill phase invert Awimjing Storing Opacific Pixel shift Replacing the maximum fill image Max FIS Override 8 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Scenes/Images On the Image tab of the Segment Menu, you can find various tools for adjusting the view of the scene/image. Segment Menu Live A ? GX Windowing of scenes/images Replacing the maximum fill image Image R RA Adjusting edge enhancement Averaging Windowing Edge Shutter Zoom/Pan Flip Flip Measurement Enhance Horizont. Vertically Opacification Integrate the frames of Annotation CLEARS .. Acquisition Max Fill Averaging Override Image Applying an electronic shutter the fill phase Storing Opacific. iFlow Invert Zooming/panning Generating the iFlow image Loop R R Flipping horizontally or vertically OS ---- Inverting grayscale values ---- Generating a CLEARstent reference image Looping through all scenes Zooming to acquisition size 9 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Scenes/Images On the Measurement tab of the Segment Menu, you can find the distance calibration and measurement tools. Segment Menu Live ? GX Automatic isocenter calibration auto Image Automatic calibration using the table-object distance Measure Measure Measurement Distance Angle auto Annotation Auto ISO Auto TOD Distance Cal Cal Calibration Distance calibration Storing Hide Drawing and measuring distance lines Drawing and measuring angles Hiding distance calibration 10 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Scenes/Images On the Annotation tab of the Segment Menu, you can find the tools for annotating images with text and graphics. Segment Menu Live ? DX T Annotating images with texts Image T Drawing polygons Annotation Measurement Text + Annotation Polygon Circle Arrow Line Pointer O Drawing circles Storing Hide Drawing arrows - + Drawing lines Using pointers Hiding/showing annotations 11 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Postprocessing Scenes/Images You can change the image display of the active image You can open the onscreen menu by pressing the menu key to postprocess the segment in the Tools menu on the touchscreen of the images. The onscreen menu is configurable in local service. Pilot control module. Tools Tools M M ... Native A Invert Distance Meas. DSAA Sensis General General Native A 2D Review Scene Directory O. Windowing O 20 Review Zoom by Factor 2 2D Review OK X2 2D Store Fluoro Display Scene Native Reference Directory L Store Ref1 Native Loop all Scenes REF Replace Mask Next Scene Store Ref2 Move Mask Opacification REFI Store Ref1 A+B Pointer K Previous Scene Windowing -- iFlow 19_ Store Fluoro Auto Pixelshift 3D Review HH Layout Gallery Max Fill Override t Pixelshift ... auto Loop all Scenes 74 Arrow T. Annotation Text ... % O Dt Auto Pixelshift auto Anatom. Background 3D Measurement 3D Care Position Measurement ... Qt Manual Pixelshift Auto TOD Calibration H Start / Pause Scene = iFlow NEZEE PURE Areuc auto Annotation ... Sys. Pos. Case Flows Display Favorites Sys. Pos. Case Flows Display Exam Favorites T Opacification Exam 12 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Default Review and Display Mode When a scene is loaded, it is first displayed as defined by the Default Review Mode. Default Review Mode LaVe A ? X You can change the default review mode via Settings > Options > Default Review Mode. Stored Flouro / RDMP LIM Review modes for fluoroscopy/Roadmap: Unstored Floure / RDMP LIH • LIH (Last Image Hold): The last fluoroscopic/roadmap image is displayed. CARD LOOP LOOP*: A scene is replayed continuously. After the last image, the same scene starts again from the DR / DSA MFH • PERI MEH beginning. 30/ DYNA TOGGLE • MFH = Max. Fill Hold: After loading a scene its maximum fill image is immediately displayed. • TOGGLE: The scene is played continuously but, unlike Loop, the review direction is reversed after DK the last image (ping-pong effect). For subtracted scenes, you can set the following display modes via Settings > View > Display Mode Display Mode REF X • Live Native Image: During roadmap or DSA, the unsubtracted live fluoroscopy image is displayed on the Ref1 segment. Display on Reference1 during ROMP and DSA: Live Native Image • Reference Image: During roadmap or DSA, the selected reference image is displayed on the Ref1 Reference Image segment. OK *optional, license needed. 13 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Correcting Patient Data In the Patient Browser, you can correct the personal data of a 4. patient. Click Yes to confirm. The Correction message prompts you to confirm your changes. 1. On the toolbar, click the Correct icon to open the Correction AF ? X Correction of Patient/Study/Series/Instance dialog box. Do you really want to change this data? Affected reading applications will be canceled -- Saved results and findings may become inconsistent. DICOM Send to Import Export Correct Delete Q/R Archive 2. Select the Patient, Study, Series or Instances tab. Yes No 3. Enter the correct patient data. 5. Carefully decide whether to remove results and findings. Please note: Data correction can affect the modification of several studies, series, or instances depending on the attribute level. The number of affected studies, series, or instances is displayed. 14 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers DICOM Query/Retrieve 1. On the toolbar of the Patient Browser, click the DICOM Q/R icon DICOM Query/Retrieve ? x to open the DICOM Query/Retrieve dialog box. ① 1 Q ④ DICOM Source Selection Search Filters 4 Q/R PACS X Search ② 2 or – – Results Series To search for related studies of the selected patient, right-click on Patient Name Patient ID Date of Birth Series Number Series Descrip ... Modality + a patient or study and choose Search Patient with DICOM Q/R from the context menu. 2. Click Source Selection to select the source where you want to ③ search for studies. 3 3. Click Search Filters to specify the search criteria. 4. Click the Search icon Q in the toolbar. 5. Select a study or series and click the Retrieve icon in the toolbar to retrieve the study. Close When the retrieval process is finished, the study is available in the 1 Source Selection 3 Results and Series list Results list of the Patient Browser. 2 Search Filters 4 Toolbar 15 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Archiving/Export/Transfer Data Export Data ? X Export DICOM data Patient Series de ... Instances . CD/DVD File System Network 2 Using the Export Data dialog box, you can export selected data in DICOM Onc zee TACE,DCT E .. DynaCT ... 390 Onc zee TACE, DCT E ... DynaCT ... 390 Target capacity sufficient format. Target F:\ You can export to the following locations: Browse • CD/DVD 1 + Up New Back" Forward • File system 3 This PC MED_SYSTEM (C:) MED_DATA (D:) • DICOM nodes, for example for archiving in the PACS Desktop Documents Downloads MED PIXEL (E:) USB Drive (F:) First select the data to be exported in the Patient Browser or in the Image ArtisSys_Image_Backup (I:) Music Pictures Directory. In the Export Data dialog box, you can refine the data selection and select the export target. 4 391.6 MB, 780 Instances Clear List Export Close Export Data dialog box 1 Data selection area 3 Export settings area 2 Export target area 4 Amount of selected data to be exported 16 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Archiving/Export/Transfer Data Exporting Data in the Image Directory Exporting data in the Patient Browser 1. Select images in the Image Directory. From the Patient Browser, any data can be transferred as one 2. Click the Export icon to start the export. The Export Data dialog box opens and data set. the selected data is displayed. 1. In the Results, Series or Instances list of the Patient 3. Adjust the relevant settings in the Export Data dialog box. Browser, select the series, studies or images you want to Image Directory Live A ? X export. Export Data ? X 2. On the toolbar of the Patient Browser, click the Export All Scenes + 3D 3D REF/ Bookmarks Patient Series de ... Instances O CD/DVD . File System . Network icon. November 20, 2014, Neuro Mikro DICOM Send to Import Export Correct Delete Q/R Archive The Export Data dialog box opens and the data you have XA VOL LAO:O CRA:O AF SCENE selected is displayed. 3. Adjust the relevant settings in the Export Data dialog box. 25 1/8: Dyna3D DSA Dual ... 1/8: Dyna3D DSA Dual ... 1/8 - 2: 5sDSA Head 17 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Archiving/Export/Transfer Data Exporting scenes/images as videos or bitmaps Export Image As Live A Path If you want to use or process images in other applications, you can export them in a common format to a C:\AXIOMITEMPICDR_OFFLINE directory of the hard disk or to USB memory. Filename Plane A NR zee PURE Aneucoil Essen_IR 152 CPF 4C 1. If you want to export to USB memory: Plug a USB Filename Plane B memory stick into the USB port of the central power control. Image Range from Image Range to 10 + 11 + 2. Click the Segment Menu icon E in the segment Select all Ranges header. Format Compression 3. Click the Storing tab. AVI Full Frames ( 4. Click the Export Image icon Segment Menu ? BX Compression Settings . The Export Image As window is displayed. Output size (in px) 1024 x 1024 5. Select/change the required settings, if necessary. Image Monitor Print Include 6. Click OK. Measurement Text Graphics ECG Annotation Storing Export Screens ... Image OK Cancel 18 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 Postprocessing SIEMENS Healthineers Archiving/Export/Transfer Data Exporting data to USB Archiving data manually in the Patient Browser If you want to export to USB memory: Plug a USB memory stick into the USB port of the central power control and select File System and DICOM Import Export Correct Delete Q/R Archive browse the target path. In the Patient Browser, you can archive data manually. 1. In the Results list of the Patient Browser, select the desired studies, series or instances. 2. Click the Send to Archive icon. Archiving will start without delay. USB port for memory stick 19 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 20 Effective Date: 23 Aug 2022 I HOOD05162003288213 Unrestricted © Siemens Healthineers, 2022
- artis
- icono
- artisicono
- icon
- ceiling
- interventional
- cardiology
- card
- radiology