ARTIS icono biplane (VE21A and higher) 3D Acquisition Video
This video will demonstrate the workflow for 3D acquisitions on the ARTIS icono biplane VE20.
Please note: Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training.
Target group: Basic user
Audio: Yes
Recommended to be viewed on the following devices: Laptop, desktop computer (sufficiently large display required)
Welcome to the artist Icono biplane 3D acquisition video. In this video you will learn how to perform 3D acquisitions. First, select the 3D acquisition protocol. If your current exam room display is configured to display the 3D Wizard, you can use the 3D Wizard to select the protocol and for acquisition guidance. You select the 3D wizard from the on screen menu. Press the key on the pilot control module to open the onscreen menu. Deflect the jogwheel to select the general 3D sharing menu and select the 3D Wizard. Alternatively, you can open the 3D wizard from the touch screen in the examination menu. Select the 3D acquisition protocol. Please note if your current procedure contains a 3D protocol, it is also possible to select the 3D protocol manually from the examination menu on the touch screen. With artist Icono, biplane 3D acquisitions are performed with plane, a floor stand positioned at the table head side or from V21 on with plain be top stand positioned from the lateral side. To ensure that there is no collision between play name, floor stand and plain be top stand playnet and plane B are positioned in the biplane head side position. In the biplane head side position both plane and plane be rotated about the isocenter. In a synchronized movement. Please note for some protocols that opstand must be moved to the park position. For example, high speed 3D and Dyna 4D protocols. It is also possible to have your system configured so that the top stand is always in the park position. To move playnet and plane bead to the biplane head side position, press down on the left joystick and deflect the joystick away from you. The system moves playnet and plane B to the start position for the 3D acquisition. When positioning the system, follow the guidance on the exam room display. Guidance messages appear for all steps of the acquisition workflow. It is a requirement for 3D acquisitions that the region of interest is positioned in the isocenter. Position the region of interest in the center in the AP position. Perform fluoroscopy briefly. Using care position, adjust the table longitudinally and transversely so that the region of interest is in the center of the field of view. Depending on the region of interest, collimation may be applied, but only in the top to bottom direction slab acquisition. Using side to side collimation must not be performed as the image quality is impaired by truncations. With the system positioned in the biplane head, side position, lateral ISIS entering can be done with plane B. Perform fluoroscopy briefly. Please check that you have the correct zoom stage selected on plane B. Using care position, adjust the tabletop height so that the region of interest is in the isocenter. The optional Laser cross might be of help during this step. When you are satisfied that the region of interest is positioned within the isocenter, you can continue with the 3D workflow and enter the test phase. To prepare, move the system to the start position for the test phase. Press on the left stand C arm joystick and deflect the joystick away from you. When the system is in the start position for the test phase, a message appears on the exam room display. It is important in the test phase to ensure that the area of rotation is free from possible collisions. Move any equipment away from the rotation zone, including the exam room display. To start the test phase, press down and deflect the left joystick away from you. The C arm will rotate around the region of interest. This test is performed at a slower speed than the later acquisition to allow a better reaction to possible required changes. Keep the joystick deflected. The test phase will end automatically. For automatic setting of acquisition parameters, you are prompted by the system at the end of the test phase to perform fluoroscopy. When the test phase is complete, the system is ready for acquisition. Before you start the 3D acquisition, ensure that you are prepared for the injection of contrast media if required. C arm rotation depends on the selected protocol, for example. In der acquisitions, the system will perform 1C arm rotation. If an injector is armed, the contrast agent will be injected. DSA acquisitions will involve 3 rotations of the arm. The mask run the return rotation no X ray. And the Phil run. The injector will be started for the fill run. The system will wait the time that is set in the X ray delay. Some acquisition protocols involve a bullace watching phase after the mask run. For example dinap V. Nuro. Acquisition can be released by the hand switch or the FOOTSWITCH. The contrast medium injection can be synced with the acquisition, or you can manually trigger the injection of contrast media using the injector interface. During the 3D acquisition, as the arm rotates around the region of interest. The 2D images are shown on the exam room and control room display. This allows you to see the anatomical structures and monitor the injection of contrast media. Continue to release X ray until the 3D run is complete. An audible signal indicates that the acquisition is complete. When the 3D acquisition is finalized, the 3D acquisition program is automatically deselected, and a 2D acquisition program is selected by default. If configured, the system can be moved back to the working position prior to entering the 3D acquisition workflow.
DSA acquisition Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. SIEMENS Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Healthineers Please contact your local Siemens Healthineers sales representative for the most current information. 0.00 0.0 Ref Image 0.0 KV 0.0 KV 0.0 W 00 W 1% The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders A:3D test phase: Start fluoro to complete 3D: Deflect joystick to move to ISO 000.6 min will be liable for damages. Examination 33.20 6.22 Navigate 33.20 6.22 17.50 position. (Plane A: AP. Plane B: lateral) Image Image +J• test phase ack Pause 1.00 rnGy 0.0 mA 0.0 ms 1.00 rnGy 0.00 mGy 0.00 mGy 0.00 ms 000.6 min 000.2 min Scene +1• Series Descr. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. 'f c'. 'f Measure Field All rights, including rights created by patent grant or registration of a utility model or design, are reserved. 20 sec. Length @ Siemens Healthcare GmbH 2021 Acquisition am x-Ray 3D wizard ARTIS
- artis
- artsi
- icono
- artisicono
- angio
- angiography
- interventional
- biplane
- 3D
- 3D acquisition
- 3D-acq
- dynaCT
- dyna3D
- ve20
- ve2
- ve20
- ve2x
- ve21
- ve3
- ve30
- ve3x
- artis ve2
- artis ve20
- artis ve2x
- artis ve21
- artis icono ve2
- artis icono ve20
- artis icono ve2x
- artis icono ve21
- artis ve3
- artis ve30
- artis ve3x
- artis icono ve3
- artis icono ve30
- artis icono ve3x