ARTIS icono/ARTIS pheno VE4 Touchscreen introduction (USA)
In this video, you will get an introduction of the menus of the touchscreen, how you navigate the touchscreen, and how you can use Favorites and the Direct Access Bar.
Target group: Basic user
Audio: Yes
Recommended to be viewed on the following devices: All (incl. tablet, smartphone)
This video will introduce you to the basic functions of the touch screen. To open a menu, press on the menu item on the touch screen. Let's first go to the settings menu. Here you can change, for example, the selected procedure and the patient position, and you can flip the image and close the patient. In the examination menu, you can change the floral and acquisition protocol and adjust parameters such as frame rate, pulse rate, and scene length. Additionally, you can access the 3D wizard. Use the Display menu to change the layout of the exam room display and the input source of the segment in the layout. The CRM Position menu provides preprogrammed system positions. In the table menu you can access functions related to the table. If your table is the standard table, you can adjust the table height. If your table is the multi tilt table, you can adjust the table height and additionally table tilt, table cradle, and table transversal and longitudinal movements. This is the Detector and Collimation menu. Here you can for example rotate and lift the detector, zoom and switch the laser light on and off. In the road map and overlay menu you can activate the functions Road map and overlay reference image. You can add your favorite settings and functions to a favorites list for easy access. Now let's see how you navigate in the touch screen menu. Move up and down to scroll through the menu items, to edit the position of the items in the menu, or to add menu items to the favorites. Perform a long touch on the touch screen. To add an item to the Favorites menu, press on the star next to the item. To exit editing mode, press the check mark at the top right of the menu. To return to the main menu, press the arrow at the top left of the touch screen. To edit the favorites, open the menu. Perform a long touch on the touch screen to enter edit mode. To change the position of a menu item, press on the left side of the item and move it to a new position. To remove an item from the favorite menu, press on the cross on the menu item. To change the frame rate and the fluoroscopy dose rate, select the Examination menu. For example, to change the fluoroscopy protocol, select the fluoroscopy protocol. The direct access bar is at the bottom of the touch screen. Here you can access your most frequently used functions. To configure the direct access bar, press on the bar for more than 5 seconds. Now we are in the editing mode and can configure the direct access bar. To do that, just drag and drop the desired menu onto the direct access bar.
1/28 2/28 Touchscreen introduction ARTIS icono, ARTIS pheno ARTIS Examination Display C-Arm Position Table Detector + C ... RDMP + Ove ... Case Flows Tools Favorites Sys. Pos. Exam 1. fluoro triplet Fluoro FL (n) C ... Pulse Rate 10 p/s Acquisition Coro v1 Frame Rate 15 f/s Series De ... Settings Region MISCEL ... 1. Exam Set ARTIS Profile 1 HF Supine Head Extension Image Flip A Acquisition Coro v1 Default ... Source 1 Live A Source 2 Ref1 A Source 3 Live B Source 4 Ref1 B Source 5 Ref2 A Layout System Pos ... Patient Transfer Left Side Right Side Head Side Left Side, Table Rotated 15º Height 86 cm Tilt Cradle -2º Transversal 0 cm Longitudinal 126 cm Define as ROI Detector + Colli ... Rotation A Zoom A 49 cm Zoom B Lift A 87 cm Lift B 123 cm Overlay Ref1 REF REF 1 +C Adjust C-Arm to R ... REF2 Measure Field Scene Len ... 10 sec. max[s] لسلسلسا Acq. Plane Scene Len ... 10 sec. Block X-ray 3D Wizard Editing Mode Fluoro Sets Series De ... Fluoro Protocol FL (-) Coro v1 FL (-) Co ... 7.5 p/s 3D Direct Pos. Anat. Pos. 3D Pos. C-Arm Detector Procedures Roadmap Overlay Please note this learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | C Siemens Healthineers AG, 2024 Siemens Healthineers HQ I Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com SIEMENS Healt Healthineers