
AI-Rad Companion - Organs RT What's new
This PDF provides an overview of everything what's new within the AI-Rad Companion Organs RT VA60.
Target group: All users
Recommended to be viewed on the following devices: All (incl. tablet, smartphone)
What’s new in AI-Rad Companion? AI-Rad Companion Organs RT VA60 siemens-healthineers.com SIEMENS Healthineers Dear AI-Rad Companion user, As more institutions are using AI Rad Companion1, you As an AI-Rad Companion user, you will automatically gain as a customer can look forward to upcoming software access to the new software version, and we would like to releases and features. Our latest version offers new provide you with news about the latest software update. features and functionalities to improve your experience with the AI-Rad Companion, as well as regular fixes. AI-Rad Companion Organs RT VA60 This update brings you a list important features which can support you in your daily routine. Here is what can you expect: Multi-Guideline Support for CT Contouring In the new version of AI-Rad Companion Organs RT we have added guideline variations for selected anatomical structures allowing to choose guidelines according to institutional preferences. Please find below the organs for which we added alternate guidelines besides the default guideline: Organ Default Guideline Alternative Guidelines Brainstem Brouwer et al. 2015 DAHANCA Jensen et al. 2020 Esophagus ROTG Kong et al. 2011 DAHANCA Jensen et al. 2020 Left Breast ROTG Kong et al. 2011 ESTRO Offersen et al. 2015 Right Breast ROTG Kong et al. 2011 ESTRO Offersen et al. 2015 Glottis Brouwer et al. 2015 DAHANCA Jensen et al. 2020 Supraglottic Larynx Brouwer et al. 2015 DAHANCA Jensen et al. 2020 1 AI-Rad Companion consists of several products that are (medical) devices in their own right, and products under development. AI-Rad Companion is not commercially available in all countries. Future availability cannot be ensured 2 Please find below an overview of all supported guidelines: Name Title Citation Bridge & Tipper CT Anatomy for Radiotherapy Bridge, P., & Tipper, D. (2017). 2017 CT Anatomy for Radiotherapy. M&K Publishing. RTOG Gay et al. Pelvic normal tissue contouring Gay HA, Barthold HJ, O'Meara E, et 2012 guidelines for radiation therapy: al. Pelvic normal tissue contouring a Radiation Therapy Oncology guidelines for radiation therapy: Group consensus panel atlas a Radiation Therapy Oncology Group consensus panel ESTRO Offersen et al. ESTRO consensus guideline Offersen BV, Boersma LJ, Kirkove C, 2015 on target volume delineation et al. ESTRO consensus guideline for elective radiation therapy on target volume delineation for of early stage breast cancer elective radiation therapy of early stage breast cancer. Radiother Oncol. 2015;114(1):3-10. doi:10.1016/j.radonc.2014.11.030. RTOG Lawton et al. RTOG GU Radiation oncology Lawton CA, Michalski J, El-Naqa I, 2009 specialists reach consensus on et al. RTOG GU Radiation oncology pelvic lymph node volumes for specialists reach consensus on high-risk prostate cancer pelvic lymph node volumes for high- risk prostate cancer. Int J Radiat Oncol Biol Phys. 2009;74(2):383-387. doi:10.1016/j.ijrobp.2008.08.002. Brouwer et al. CT-based delineation of organs Brouwer CL, Steenbakkers RJ, 2015 at risk in the head and neck Bourhis J, et al. CT-based region: DAHANCA, EORTC, delineation of organs at risk in the GORTEC, HKNPCSG, NCIC CTG, head and neck region: DAHANCA, NCRI, NRG EORTC, GORTEC, HKNPCSG, NCIC Oncology and TROG consensus CTG, NCRI, NRG guidelines Oncology and TROG consensus guidelines. Radiother Oncol. 2015;117(1):83-90. doi:10.1016/j.radonc.2015.07.041. Gregoire et al. Delineation of the neck node Grégoire V, Ang K, Budach W, 2014 levels for head and neck et al. Delineation of the neck node tumors: a 2013 update. levels for head and neck tumors: DAHANCA, EORTC, HKNPCSG, a 2013 update. DAHANCA, EORTC, NCIC CTG, NCRI, RTOG, TROG HKNPCSG, NCIC CTG, NCRI, RTOG, consensus guidelines TROG consensus guidelines. Radiother Oncol. 2014;110(1):172-181. doi:10.1016/j.radonc.2013.10.010. 3 Name Title Citation RTOG Jabbour et al. Upper abdominal normal organ Jabbour SK, Hashem SA, Bosch W, 2013 contouring guidelines and atlas: et al. Upper abdominal normal a Radiation Therapy Oncology organ contouring guidelines and Group consensus atlas: a Radiation Therapy Oncology Group consensus. Pract Radiat Oncol. 2014;4(2):82-89. doi:10.1016/ j.prro.2013.06.004. Lee et al. Target Volume Delineation Lee, N., Riaz, N., & Lu, J. (2014). 2014 for Conformal and Intensity- Target Volume Delineation for Modulated Radiation Therapy Conformal and Intensity- Modu- lated Radiation Therapy. Springer International Publishing. IASLC Rusch et al. The IASLC lung cancer staging Rusch VW, Asamura H, Watanabe H, 2009 project: a proposal for a new et al. The IASLC lung cancer staging international lymph node map project: a proposal for a new in the forthcoming seventh international lymph node map in edition of the TNM classification the forthcoming seventh edition for lung cancer of the TNM classification for lung cancer. J Thorac Oncol. 2009;4(5):568-577. doi:10.1097/ JTO.0b013e3181a0d82e. DAHANCA Jensen et al. The Danish Head and Neck Jensen K, Friborg J, Hansen CR, 2020 Cancer Group (DAHANCA) 2020 et al. The Danish Head and Neck radiotherapy guidelines Cancer Group (DAHANCA) 2020 radiotherapy guidelines. Radiother Oncol. 2020;151:149-151. doi:10.1016/j.radonc.2020.07.037. RTOG Kong et al. Consideration of dose limits Kong FM, Ritter T, Quint DJ, et al. 2011 for organs at risk of thoracic Consideration of dose limits for radiotherapy: atlas for lung, organs at risk of thoracic radio- proximal bronchial tree, therapy: atlas for lung, proximal esophagus, spinal cord, ribs, bronchial tree, esophagus, spinal and brachial plexus cord, ribs, and brachial plexus. Int J Radiat Oncol Biol Phys. 2011;81(5):1442-145 7. doi:10.1016/ j.ijrobp.2010.07.1977 4 New Organs for CT contouring The following new structures will become available for all users and brings the total of OAR to 178 supported organs: Anatomic Group Organ Abdomen Bowel Bag Head and Neck Lacrimal Gland Lacrimal Gland Left Lacrimal Gland Right Pituitary Gland Pelvis Femoral Head Femoral Head Left Femoral Head Right Sacrum Hip Bone Hip Bone Left Hip Bone Right Thorax Humeral Head Humeral Head Left Humeral Head Right Thoracic Lymph nodes N1 Station 10: Hilar Nodes N1 Station 10: Hilar Nodes Left N1 Station 10: Hilar Nodes Right N2 Station 1: Highest Mediastinal Nodes N2 Station 1: Highest Mediastinal Nodes Left N2 Station 1: Highest Mediastnial Nodes Right N2 Station 2: Upper Paratracheal Nodes N2 Station 2: Upper Paratracheal Nodes Left N2 Station 2: Upper Paratracheal Nodes Right N2 Station 3: Prevascular and Retrotracheal N. N2 Station 3A: Prevascular Nodes N2 Station 3P: Retrotracheal Nodes N2 Station 4: Lower Paratracheal Nodes N2 Station 4: Lower Paratracheal Nodes Left N2 Station 4: Lower Paratracheal Nodes Right N2 Station 5: Subaortic Nodes N2 Station 6: Para-aortic Nodes N2 Station 7: SubCarinal Nodes N2 Station 8: Paraesophageal Nodes N2 Station 9: PulmonaryLigamentNodes N2 Station 9: Pulmonary Ligament Nodes Left N2 Station 9: Pulmonary Ligament Nodes Right 5 Miscellaneous We have rearranged the contoured organs groupings for Cardiac, previously the following structures were listed under thorax, and will now be under cardiac: CA Left Anterior Descending Artery (LAD) and the Pulmonary Artery. Do you know PEPconnect? PEPconnect is our education and performance experience • Access to education and real-time performance for healthcare professionals. Its broad portfolio of support, anytime, anywhere, on any device for all Medical Imaging and Therapy, Laboratory Diagnostics, AI-Rad Companion products. POC, and other healthcare-related topics is available via • Intuitive-to-use and easy-to-navigate interface e-learning, competency-based education, webinars, job • aids, and more. Focused on increasing the knowledge, Content in up to 7 languages skills, and abilities of individual learners, as PEPconnect As a customer, you have free and unlimited access offers: to the PEPconnect platform directly from the AI-Rad Companion, by clicking on the “Training Material” icon. SIEMENS Healthineers Al-Rod Companion ? * Extension Show All Extensions Queued Worklist (6) Completed Failed AM Q Search General information More information about the new version of all the On the same location user manuals can be consulted AI-Rad Companion products can be found in the release or downloaded too. information. Other news and facts about the product can be These documents can be accessed from the following found on the product webpage: webpage: siemens-healthineers.com/ai-rad-companion https://doclib.siemens-healthineers.com/home or via the question mark in the access bar. Please select your language and country of origin for the correct documentation. 6 Siemens Healthineers Headquarters Siemens Healthineers AG Siemensstr. 3 91301 Forchheim, Germany Phone: +49 9191 18-0 siemens-healthineers.com Published by Siemens Healthineers AG · 1124 online only · ©Siemens Healthineers AG, 2024
- organsrt
- airad
- ai-rad companion
- ai rad
- ai rad companion
- articial
- intelligence
- artificial intelligence
- what's new
- QR700013208