
AI-Rad Companion - Brain MR (VA50) What's new? Job Aid
This PDF provides an overview of everything what's new within the AI-Rad Companion Brain MR VA50.
Target group: All users
Recommended to be viewed on the following devices: All (incl. tablet, smartphone)
What’s new in AI-Rad Companion? Dear AI-Rad Companion user, As more institutions are using AI-Rad Companion1, you as a customer can look forward to upcoming software releases. Our latest version offers new features and functionalities to improve your experience with the AI-Rad Companion, as well as fixes. As an AI-Rad Companion user, you will automatically gain access to the new software version and we would like to provide you with news about the latest software update. siemens-healthineers.com/ai-rad SIEMENS Healthineers AI-Rad Companion Brain MR (VA50) This update will bring you new features which can support you in your daily routine. AI-Rad Companion Brain MR now also provides a presentation of the results in additional planes (axial, sagittal and coronal): S E'I Longitidunal comparison: AI-Rad Companion Brain MR supports comparison of current and prior data sets to help in tracking progression of Morphometry and White Matter Hyperintensities (WMH) changes. This functionality is enabled automatically and can be disabled in the configuration menu for Morphometry and/or White Matter Hyperintensities: SIEMENS .. : Healthineers Al-Rad Companion COD Settings X General Brain MR Common Settings Al Results Morphometry Follow-Up White Matter Hyperintensities Data Selection Process only image data that meets ADNI standard 2 AI-Rad Companion For WMH, a progression map overlay will be created when the follow-up functionality is enabled. This feature is enabled by default and the color can be defined by the user. Progression Map Overlay Transparency (%) 50 New or Enlarged The AI-Rad Companion Brain MR will compute the rate of change of volume of brain structures in percent per year and count the volume of new or enlarged WMH. Morphometry Prior Current Age : 34 yrs 35 yrs Examination Date : 25.06.2014 16.06.2015 Input Data : MPRAGE MPRAGE Image Quality : Not assessed: n.a. - Range: [n.a.] Not assessed: n.a. - Range: [n.a.] Segmentation Quality : Acceptable: 0.74 - Range: [0.70 - 1.00] Acceptable: 0.74 - Range: [0.70 - 1.00] All Deviations(1/2) Structures Volume Percentile Rate of Change (%/vr Total Brain Parenchyma 980.5 <1 -0.97 Cerebral spinal fluid 412.7 . >99 2.87 WM Frontal lobe - Left 57.5 <1 -2.82 WM Frontal lobe - Right 58.3 <1 2.61 Ventricles - Left 26.6 99 0.30 Ventricles - Right 24.2 99 2.10 Ventricles 55.8 99 0.81 Cerebellum (WM +GM) 101.1 1.48 WM Parietal lobe - Right 37.9 2.24 Ventricles - 3rd ventricle 2.7 98 -0.19 3 AI-Rad Companion PDF Report: Additionally, the AI-Rad Companion Brain MR automatically creates a comprehensive report that can be shared with the patient or referring physician. The PDF document contains the quantitative analysis as well as graphical elements. Name ID Acc. Nr. Date of Birth Sex SIEMENS : Name ID Acc. Nr. Date of Birth Sex Healthineers ... SIEMENS .: Morphometry WMH Morphometry WMH Healthineers ... M_W_FU_PID_0001 AC_123456789 01.01.1980 Male M_W_FU_PID_0001 AC_123456789 01.01.1980 Male Long Long itudinal Demo Pat... itudinal Demo Pat... White Matter Hyperintensities Morphometry Prior Current Prior Current Age: 34yrs 35yrs Age: 34yrs 35yrs Examination Date: 25.06.2014 16.06.2015 Examination Date: 25.06.2014 16.06.2015 Input Data: FLAIR FLAIR Input Data: MPRAGE MPRAGE MPRAGE MPRAGE Image Quality: Not assessed: n.a. - Range: [n.a.] Not assessed: n.a. - Range: [n.a.] Spatial Distribution Segmentation Quality: Acceptable: 0.74 - Range: [0.70 - 1.00] Acceptable: 0.74 - Range: [0.70 - 1.00] Area Count Volume [ml] All Deviations Structures Volume Rate of Change ● Juxtacortical 6 0.4 [ml] Percentile [%/yr] Total Brain Parenchyma 980.5 <1 -0.97 ● Periventricular 4 28.1 Cerebral spinal fluid 412.7 >99 2.87 ● Deep white matter 26 0.2 WM Frontal lobe - Left 57.5 <1 -2.82 ● Infratentorial 5 0.1 WM Frontal lobe - Right 58.3 <1 -2.61 Total 41 28.9 Ventricles - Left 26.6 99 -0.30 Ventricles - Right 24.2 99 2.10 Progression Ventricles 55.8 99 0.81 Types Count Volume [ml] Cerebellum (WM +GM) 101.1 2 -1.48 ● New or Enlarged 9 0.7 WM Parietal lobe - Right 37.9 2 -2.24 Ventricles - 3rd ventricle 2.7 98 -0.19 Rate of Change = Annualized change calculated using current and prior values White matter 374.2 2 -1.81 General Info Pons 12.6 3 -0.05 GM Frontal lobe - Left 87.2 5 -0.25 Gray matter 606.3 5 -0.45 GM Cingulate gyrus - Right 8.1 6 -2.57 WM Parietal lobe - Left 40.6 6 -1.39 Thalamus - Left 6.2 7 -3.98 Deviations - 10th / 90th percentile. = Rate of Change = Annualized change calculated using current and prior values Cautions Cautions Input data of both current and prior study not consistent with the morphometry protocol guideline. Please check validity of both Input data not consistent with the recommended guideline. current and prior study's volumetric results and the follow-up Please check the validity of WMH results. results. 1 / 7 2 / 7 4 AI-Rad Companion Note: The PDF report is generated only when the data privacy is disabled in the teamplay digital health platform because patient information will be documented in the PDF report. In order to make changes, open the configuration page of the teamplay Receiver. Consider the data privacy regulations of your institution. Privacy settings for the selected application Privacy level The privacy settings of the following section are applied to the AE titles of the selected Cloud application. Depending on the selected privacy level, different data minimization steps are applied to the content of DICOM files before they are uploaded. Please note: Study updates with different privacy profiles are rejected. Show more Standard (current institution setting) privacy By activating these options, you modify the "Standard privacy" privacy profile. Keep UIDs and accession number Keep patient age Keep institution personnel data O High privacy O Restrictive O No data minimization Customized privacy profile Record patient identifiers for re-identification This option enables you to use patient information within partner application results while identifiable sensitive patient information does not leave the sphere of your institution. Using the re-identification feature does NOT restore ALL data of the original study. Show more Record patient identifiers for re-identification Cancel Save The functionality needs to be enabled on the configuration page of AI-Rad Companion Brain MR: SIEMENS Healthineers ... Al-Rad Companion Settings General Brain MR Chest CT Common Settings Data Transfer Morphometry Morphometry White Matter Hyperintensities Al Result Report Al Result Report White Matter Hyperintensities Structured Report Structured Report PDF Report V PDF Report 5 AI-Rad Companion Do you know PEPconnect? PEPconnect is our education and performance experience for healthcare professionals. Its broad portfolio of Medical Imaging and Therapy, Laboratory Diagnostics, POC, and other healthcare-related topics is available via e-learning, competency-based education, webi- nars, job aids, and more. Focused on increasing the knowledge, skills, and abilities of indi- vidual learners, PEPconnect offers: • Access to education and real-time performance support, anytime, anywhere, on any device for all AI-Rad Companion products. • Intuitive-to-use and easy-to-navigate interface As a customer, you have free and unlimited access to the PEPconnect platform directly from the AI-Rad Companion, by clicking on the “Training Material” icon. SIEMENS .. Healthineers Al-Rad Companion R ? ¢ COD Extension Show All Extensions Queued Worklist (9) Completed Failed All Q Search 6 AI-Rad Companion General information: More information about the latest versions of all AI-Rad Companion products can be found in the release information. These documents can be accessed from the following webpage: https://doclib.siemens-healthineers.com/home or via the question mark in the access bar. Please select your language and country of origin for the correct documentation. On the same location user manuals can be consulted or downloaded too. Other news and facts about the product can be found on the product webpage: www.siemens-healthineers.com/ai-rad-companion 7 AI-Rad Companion 1 AI-Rad Companion consists of several products that are (medical) devices in their own right, and products under development. AI-Rad Companion is not commercially available in all countries. Future availability cannot be ensured. Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Published by Siemens Healthcare GmbH · Online · 14136 1023 · ©Siemens Healthcare GmbH, 2023
- ai-rad companion
- ai rad
- ai rad companion
- articial
- intelligence
- artificial intelligence
- Brain MR
- brain mr
- Brain MR
- brain
- MR
- what's new