
AI-Rad Companion - Brain MR Follow-Up Video | Onboarding Practices Video (Part 2)
This video provides an introduction to the onboarding practices and requirements with AI-Rad Companion Brain MR Follow-Up.
Target group: All users.
AI Rad Companion Brain Mr. Follow. Up onboarding practices and requirements. Key features and requirements. For AI, RAD Companion, Brain, Mr. Follow up. For Morphometry and White Matter, Hyperintensity is enabled by default. The retention. For Long Term Storage, LTS is configurable for processing morphometry follow up. The time interval between the current and the prior scan should be equal or higher than 180 days and less than the retention. The scan parameters of both scans, current and prior, shall be the same for processing in plane Resolution, size of the image, number of rows and number of columns, slice thickness, TI, inversion time. TR repetition time, Magnetic field strength and auto align. For processing white matter hyperintensity, follow up. The time interval between the current and the prior scan should be less than the retention. Both scans prior and current, shall be from Siemens Health and Years 3T Systems, automatic processing and long term storage. LTSA new software version of AI RAD Companion Brain Mr. will be rolled out and available at your institution. The long term storage for Brain Mr. is active by default. A patient gets his first Brain Mr. examination, followed by the automated processing of AI Rad Companion Brain Mr. The AI RAD Companion Brain Mr. Results are saved in the LTS of AI Rad Companion for the current examination. Relevant data are stored in LTS upon completion of the case. All configured AI Rad Companion Brain Mr. results will be sent to Pax. The same patient comes in for a follow up examination after a certain. For example three to six month and gets his follow up Brain Mr. examination again. AI Rad Companion automatically calculates the AI Rad Companion Brain Mr. results. And pulls the prior results for this patient from the LTS. If image requirements are fulfilled and the delta is equal or higher than 180 days, all configured AI RAD Companion, Brain Mr. results will be sent to PAX for the follow up examination. Prior data are automatically deleted from the LTS according to the Retention Onboarding Best Practices Manual or. Bulk upload. The manual upload of existing prior Mr. data to AI RAD Companion Brain Mr. is possible. If the upload was completed before the current examination, then the follow up will be performed automatically. A list of prior data can be sent in bulk for selected patients from PAX to AI. RAD Companion, Brain Mr. Long Term Storage will be initialized for respective follow up cases in the future Please note. Brainmr follow up for already processed data from the prior software version will not be available automatically. To leverage the functionality of LTS and follow up, the data needs to be sent again to AI Red. Companion to get reprocessed with software version Virginia 50.
SIEMENS Healthineers Al-Rad Companion Brain MR - Follow-Up Onboarding Practices & Requirements Key Features & Requirements Key Features Follow-Up for Morphometry and White Matter Hyperintensity is enabled by default Retention period for long-term storage (LTS) is configurable . For processing Morphometry Follow-Up : The time interval between the current and the prior scan should be 2 180 days and < the retention period (long term storage) Scan parameters of both scans (current and prior) shall be the same for processing: In-plane resolution Slice thickness TR (Repetition Time) Magnetic field strength Auto Align . For processing White Matter Hyperintensity Follow-Up : The time interval between the current and the prior scan should be < the retention period (long term storage) Both scans (prior and current) shall be from Siemens Healthineers 3T systems Unrestricted @ Siemens Healthcare GmbH, 2023 Size of the image (number of rows and number of columns) On-Boarding Best Practices - Automatic processing and LTS* timeline Long-term storage Al-Rad Companion Brain MR VA50 The LTS* is active by default Patient 1st scan & & Al-Rad Companion Brain MR results Results are saved in the LTS* of Results are sent to PACS if PACS configured Patient 2nd/Follow-Up scan (2180 days delta to prior for Morphometry) e.g. 3-6 month Prior study is pulled up from the LTS* and compared to the Follow-Up data. New results are saved in the LTS* of Al-Rad Companion. Prior data is automatically deleted from LTS according to retention period Manual upload of prior data Bulk upload of prior data sent for selected patients & Al-Rad Companion Brain MR results nion Brain MR If completed before the current examination, then Long-term storage will be initialized for respective Follow-Up will be performed automatically Follow-Up cases in the future Results are sent e version will not be available to PACS if of LTS and Follow-Up Companion to get re-processed with sortware version VA50. On-Boarding Best Practices - Manual or Bulk upload · Manual upload of existing prior MR data to Al-Rad · A list of prior data can be sent for selected patients Companion Brain MR from PACS to Al-Rad Companion Brain MR Please note: Brain MR Follow-Up for already processed data from the prior software version will not be available automatically. To leverage the functionality of LTS and Follow-Up, the data needs to be send again to Al-Rad Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthcare GmbH 2023
- ai-rad companion
- ai rad
- ai rad companion
- articial
- intelligence
- artificial intelligence
- Brain MR
- brain mr
- Brain MR
- brain
- MR
- follow up
- follow-up