AI-Rad Companion - Brain MR Follow-Up | Configuration Settings Video (Part 3)
This video provides an introduction to the configuration settings of AI-Rad Companion Brain MR Follow-up.
Target group: All users.
AI Red Companion Brain MRVA 50 Follow up configuration settings to. Assess the rate of change of volumes of brain structures as well as the count and volume of new or enlarged white matter hyperintensities. You can perform the follow up evaluation by comparing the brain structures with known prior data. You can compare brain structures or the new or enlarged white matter hyperintensities in two time points. And if more than one scan is found, the latest one is used for the comparison for a scan to be considered as a prior. Study for morphometry follow up. The time interval between the current and the prior scan should be greater than or equal to 180 days and less than the. Retention. For a scan to be considered as a. Prior study for white matter hyperintensities follow. Up The time interval between the current and the prior scan should be less than the retention. Configuring the Data Retention. In Long Term Storage, you can configure the retention period of MP, rage or FLARE data for follow up studies so that prior scans are stored in Long Term Storage LTS. The prior scan information can be retrieved later to be compared with the current scans. The result DICOM objects include the prior MPR series to align with the current time points. The data is automatically deleted from the LTS after the retention. Is complete. First, use the arrows to adjust the follow up data value to configure the maximum time period data is retained for follow up processing. Then click Save. Changes are only applied to cases that are uploaded after you save your configuration. By default, the data retention. For follow up is 14 months. By adjusting follow up data you can increase or decrease the. Data retention period from 7:00 months to 99 months decreasing. The long term storage. For. All cases will result in the deletion. Of data that is older than the newly configured time. Configuring morphometry follow up settings. By default, Follow Up is enabled In the AI Results section, click the Follow Up toggle button to deactivate Follow up for Morphometry. Click the Follow Up toggle button again to reactivate. Follow up for morphometry, then click Save to apply your settings. Configuring white matter hyperintensities Follow Up settings. By default, Follow Up is enabled in the AI Results section. Click the Follow up toggle button to deactivate Follow up for White matter hyperintensities. Click the Follow up toggle button again to reactivate Follow. Up for white matter hyperintensities, then click Save to apply your settings.
14 13 15 16 50 Al-Rad Companion Brain MR VA50 Follow-Up configuration settings SIEMENS Morphometry Follow-Up: Time interval between the current and the prior scan should be ≥ 180 days and < the retention period (long term storage) White Matter Hyperintensities Follow-Up: should be < the retention period (long term storage) Settings Queued Worklist (2) Completed Failed All Search Accession No. Study / Series Description Information empty. Completed Failed All Q Search General Brain MR Common Settings Data Transfer Morphometry White Matter Hyperintensities Al Result Report Structured Report PDF Report Image series Deviation Map WMH Map Label Map Registered FLAIR Fused Deviation Map Progression Map Fused Label Map Fused WMH Map Fused Progression Map Image orientation Axial Coronal Sagittal Export Restore Default Settings Send Al results Automatically to-PAGSs made apply to all users and will come into effect for the next processed cases. Cancel Save Send Al results Automatically to PACS Data Selection O Automatic data selection User-defined data selection Selection is based on the following series description: MPRAGE Series description FLAIR Series description Data Retention Period Follow Up Data Months Changes made apply to all users and will come into effect for the next processed cases. The Retention Time describes how long the series of the prior examination are retained. Be aware that the follow-up function is not supported without reference data from the prior examination. Decreasing the long term storage period for all cases will result in the deletion of data that is older than the newly configured time period. Are you sure you want to proceed? By default, the Data Retention Period for Follow-Up is 14 months From 7 to 99 months Send Al results Automatically to PAGSs made apply to all users and will come into effect for the next processed cases. Al Results Follow-Up Process only image data that meets ADNI standard Visualization Label Map Overlay Transparency (%) Deviation Map Overlay Threshold Percentile Deviations 10th / 90th Max. Deviations Waiting Time Period for FLAIR Series Wait time [minutes] WMH Map Overlay Progression Map Overlay Periventicular New or Enlarged Juxtacortical Infratentorial Deep white matter Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Siemens Healthcare GmbH 2023 He Healthineers
- ai-rad companion
- ai rad
- ai rad companion
- articial
- intelligence
- artificial intelligence
- Brain MR
- brain mr
- Brain MR
- brain
- MR
- follow up
- follow-up