This job aid explains how to view and print sample results​ on the ADVIA® 2120i System.

ADVIA 2120i SIEMENS Healthineers View Sample Results When a sample is analyzed, the results are automatically sent to the connected Laboratory Information System. However, you may also review sample results manually. 1. Navigate to Operations > Sample List. Sample ID Y Date/Time Y Sample Type Y Selectivity Patient ID 2. Select a sample. Y Rack/Tube Y Y Specimen Y Sent to LIS Y Total Stored Samples 1343 BCKGRND COUNT 4/18/2022 6:21:31 PM Refresh CBCDiffRetic 00 WB Number Of Selected Samples 45 3. Select View Sample Results. CONTROL2015 4/18/2022 6:51:07 PM Control CBCDiffRetic 00 WB CONTROL2015 4/18/2022 6:53:17 PM Control CBCDiffRetic WB Start Date 4/18/2022 15 4. The results screen is 00 2 1198-1 4/18/2022 6:57:39 PM Patient CBC 00 WB End Date 4/20/2022 75 displayed. 1198-1 4/18/2022 6:58:23 PM Patient CBCDiffRetic 00 WB 5. The first time the Sample List BCKGRND COUNT 4/18/2022 7:04:40 PM Refresh CSF_BACKGROUND CSF 5 Search Clear displays, only samples CSFHO 4/18/2022 7:07:28 PM Patient CSF 00 CSF 1198-1 4/18/2022 7:11:37 PM Patient CBCDiff 3 WB processed on the current day 1198-1 4/18/2022 7:15:38 PM Patient Retic 3 WB 1198-1 4/18/2022 7:21:10 PM Patient Retic WB O Delete Selected Samples show on the screen. Use the 31 1198-1 4/18/2022 7:25:20 PM Patient CBCRetic 31 WB O Delete Samples before a date |4/20/2022 15 search function to enter the BCKGRND COUNT 4/18/2022 7:32:18 PM Refresh CSF_BACKGROUND 00 CSF O Delete Samples for a type start and end dates of the CSFHC 4/18/2022 7:34:42 PM Patient CSF 00 CSF 1198-1 4/18/2022 7:37:00 PM Patient CBCDiff 00 WB samples to display additional 1198-1 4/18/2022 7:37:47 PM Patient CBC 00 WB samples. 1198-1 4/18/2022 7:38:33 PM Patient CBCDiffRetic WB Delete Clear 1198-1 4/18/2022 7:40:31 PM Patient CBCRetic 00 WB 1198-1 4/18/2022 7:41:29 PM Patient Retic 00 WB 1198-1 4/18/2022 7:45:21 PM Patient CBCDiffRetic 31 WB 1198-1 4/18/2022 7:51:07 PM Patient CBC 3 10 WB 1198-1 4/18/2022 7:52:44 PM Patient CBCDiff 00 WB 1198-1 4/18/2022 7:53:43 PM Patient Retic 100 WB Note: Retransmit to LIS View Sample Results Anonymize Patient Data Anonymize All Print Print Sample Results Samples can also be deleted by 3 1 selecting the Delete button. Effective Date: 18-May-2022| HOOD05162003277428 Unrestricted © Siemens Healthineers, 2022 ADVIA 2120i SIEMENS Healthineers Results Screen The left side of the results screen displays results for the sample. CBC Diff Retic A letter (L or H) next to a result indicates a result that is out of range (either Low or High). Whole Blood Header Sample ID Aspiration Date/Time 12/20/2016 10:52:21 AM This screen can also be configured to highlight results in red (out of Sample Type PATIENT range) or green (in range). Rack and Position 4, 1 Routine CBC WBC L 4.42 × 103 Cells/uL If a result is flagged, an asterisk (*) will be displayed alongside that RBC 5.14 x 106 Cells/uL HGB 15.7 g/dl result. HCT 46.7 MCV 90.8 fL MCH 30.6 pg (Continued on next page) MCHC 33.7 g/dl CHCM 34 g/dl CH 30.8 pg RDW 12.1 % HDW 2.21 g/dl PLT 261 x 103 Cells/uL Reti MPV 7.4 fL Routine Retic % # Retic 2.17 111.4 x109 Cells/L CH H 37.2 pg CH H 34.8 Routine WBC Differential % # WBC L 4.42 x 103 Cells/uL Neut 66.1 2.92 x103 Cells/uL Lymph 19.5 L 0.86 x 103 Cells/uL Mono H 9.6 0.42 × 103 Cells/uL < 2 Effective Date: 18-May-2022| HOOD05162003277428 Unrestricted © Siemens Healthineers, 2022 ADVIA 2120i SIEMENS Healthineers Results Screen (continued) 2 1 X 1. Close the results screen. It will automatically appear the next Results time a sample is processed. 2. Disable the results screen. It will not automatically appear after each sample is processed. RBC Volume RBC Rate Edit View 6 3. Histograms and cytograms. Sample System Flags 4. Print - Generates a default PDF report of all results and BASO Rate RBC HC histograms. PEROX BASO RBC VHC 7 5. Print Alt. • If a customized print configuration exists for this sample PEROX Rate HGB Trans type, this button will generate that customized PDF report. 3 • If no customization exists, this button will generate the same default PDF as the Print button. Platelet Volume Retic CH 6. Edit View tab. Retic Scatter Abs. • Display additional result sets, cytograms, and histograms for the current displayed sample. Retic Rate Retic Absorption 7. Sample System Flags tab. • Display the sample/system flags set on the sample and a list of flagged results for each flag. 4 Print Print ALt. 5 3 Effective Date: 18-May-2022| HOOD05162003277428 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com 4 Effective Date: 18-May-2022| HOOD05162003277428 Unrestricted © Siemens Healthineers, 2022

  • 120
  • 2120
  • advia2120i
  • advia2120