ADVIA® 2120i Version 7 Software Quality Control Capabilities Job Aid
This job aid explains the quality control capabilities of the version 7 software on the ADVIA® 2120i System.
SIEMENS ADVIA 2120i Healthineers Quality Control Capabilities You can import control data from control assay files or control assay barcode sheets. Control data can also be entered manually. Control data is only used to flag results with a high or low flag on the Results screen and printed reports. No out-of-range indication is sent in the data stream from the analyzer. Quality Control based on control results must be performed on external data management systems (e.g., Laboratory Information System, Atellica Data Manager). Run control samples as you would patient samples. Control Setup Admin Instrument Operations Logs Utilities Procedures Customize Communication Error with Analyzer Setup Next Sample Human Patient CBC / DIFF Test Name Y Target Value Y Range Value Y Unit Text Sample Id Prefix CONTROL Save WBC 15.83 2.50 x 103 Cells/UL Lot Expiry WBCP 16.12 2.50 x103 Cells/UL Control Name Y Lot Number Y CBC/Diff High 3041 6/24/2022 RBC 5.32 0.30 x 106 Cells/UL 6/24/2022 16.30 g/dl CBC/Diff Low 1041 HGB 0.70 6/24/2022 47.50 3.80 % CBC/Diff Normal 2041 HCT 1045 7/24/2022 MCV 89.20 5.00 fl CBC/Diff Low CBC/Diff High 3045 7/24/2022 MCH 30.60 2.00 pg CBC/Diff Normal 2045 7 / 24 / 202 MCHC 34.30 3.00 g/dl CSF Level 1 1049 7/24/2022 CHCM 34.00 3.00 g/dl 2049 7/24/2022 RDW 13.80 2.20 % CSF Level 2 2042 6/24/2022 HDW 1.69 1.00 Retic High g/dl 60.00 103 Cells/UL Retic Low 1042 6/24/2022 PLT 468.00 MPV 7.10 2.00 %NEUT 67.80 10.00 % %LYMPH 17.40 5.00 % CBC/Diff High 3041 ICHCM Target Value 0.00 Control Name Lot Number Test Name Unit Text Range Value 0.00 Expiration Date 24/06/2022 Add New Save Delete Add New Save Import From File Delete Delete All Expired Template Effective Date: 27 May 2019 | HOOD05162003010284 1 Effective Date: 18-May-2022| HOOD05162003277428 Unrestricted © Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com Template Effective Date: 27 May 2019 | HOOD05162003010284 2 Effective Date: 18-May-2022| HOOD05162003277428 Unrestricted © Siemens Healthineers, 2022
- 120
- 2120
- advia2120i
- advia2120