This job aid explains how to manually empty the waste on the ADVIA® 2120i Hematology system.

ADVIA 2120i Empty Waste – As Needed Manual Waste Removal With an Autowaste Assembly The Autowaste eliminates the need to manually empty waste when it is connected to a waste , 10 psi ‹ disposalsystem and set to automatic mode. If you need to manually empty the waste, perform the following steps: Manual SIM 1. Make sure that the analyzer is not sampling. Automatic 2. Turn the mode selector knob on the waste removal assembly tray from Automatic to Manual Mode (this will take 2–5 minutes to empty). selector knob 3. Look for air bubbles in the discharge line. The air bubbles indicate the container is empty. 4. After the waste container is empty, turn the mode selector knob to Automatic mode. 5. Restart sampling on the analyzer. Waste line Vacuum line ManualWasteRemoval With a Manual Waste Container 1. Make sure that the analyzer is not sampling. 2. Disconnect the waste line and the vacuum line. To do this, press the buttons on the quick- Level release connectors and pull the lines straight up. switch 3. Disconnect the level switch sensor connector by pressing its button. sensor connector 4. Empty the full container by opening the spigot into a drain in accordance with laboratory policy. 5. When the waste container is empty, close the spigot. 6. Verify spigot is closed securely. 7. Connect the waste line, vacuum line and level sensor to the emptied container. 8. Restart sampling on the analyzer. Spigot Template Effective Date: 27 May 2019| HOOD05162003010284 1 Effective Date: 18-May-2022| HOOD05162003277428 Unrestricted© Siemens Healthineers, 2022 SIEMENS Healthineers Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2022 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens-healthineers.com Template Effective Date: 27 May 2019| HOOD05162003010284 2 Effective Date: 18-May-2022| HOOD05162003277428 Unrestricted© Siemens Healthineers, 2022

  • 120
  • 2120
  • advia2120i
  • advia2120