ADVIA® 2120i Autoslide Weekly Shutdown and Startup
This interactive video demonstrates how to perform a weekly shutdown and startup on the ADVIA® 2120i Autoslide.
Continue Unrestricted © Siemens Healthineers, 2021 Job Aid Effective Date: 11-Aug-2021| HOOD05162003214634 Template Effective Date: 27 May 2019 | HOOD05162003010284 The animation of the dot pulse can be optionally switched off on the master layout. Go to View > Slide Master After that go to Animations > Animations Pane. Select additional title motifs from the layout palette. Go to Home > Slides > Layout Unrestricted © Siemens Healthineers, 2021 Job Aid Effective Date: 11-Aug-2021| HOOD05162003214634 Continue Shutdown ADVIA® 2120i Autoslide Weekly Shutdown and Startup Introduction Welcome to the ADVIA 2120i Autoslide Weekly Shutdown and Startup video. The weekly shutdown must be completed once a week in order to avoid clogging the lines. Following the Weekly Shutdown, the Weekly Startup procedure must be performed. This video will show you how to perform both procedures. ADVIA® 2120i Autoslide Weekly Shutdown Methanol shutdown you will need To perform a weekly shutdown, you will need methanol and four empty reagent bottles. Methanol is highly flammable and dangerous. The use of methanol can cause very serious irreversible effects through inhalation, if in contact with skin, or if swallowed. So, before you begin this procedure, ensure you are using personal protective equipment and have proper ventilation. Select Operations Home Screen To begin the weekly shutdown, first, select the Operations icon. Select Operations to continue. Select AutoSlide Operations Screen Then, select AutoSlide. Select AutoSlide to continue. Select Weekly Shutdown Autoslide Operations Select Weekly Shutdown. Select Weekly Shutdown to continue. Weekly Shutdown The steps for the Weekly Shutdown are displayed on the screen. This video will demonstrate these instructions for you, step-by-step. ADVIA® 2120i Autoslide Weekly Shutdown Methanol 300mL 300mL shutdown methanol to bottles First, pour approximately 300 milliliters of methanol into 2 of the empty reagent bottles. ADVIA® 2120i Autoslide Weekly Shutdown 300mL 300mL Stain 1 Stain 2 shutdown staining straws to one bottle Remove both staining straws from their stain bottles and place them in one of the empty bottles. Close the stain bottles with their caps. ADVIA® 2120i Autoslide Weekly Shutdown 300mL 300mL Buffer shutdown buffer straw to empty bottle Remove the buffer straw and place it in the other empty container. Close the buffer container. ADVIA® 2120i Autoslide Weekly Shutdown 300mL 300mL shutdown status before next You should now have the following setup: One bottle with both staining straws One bottle with the buffer straw Two bottles, each with 300 milliliters of methanol Select Next Shutdown steps1-3 complete We have completed the first three steps. Select next to continue. Select Next to continue. Shutdown empty lines The next set of steps display on the screen. ADVIA® 2120i Autoslide Weekly Shutdown 300mL 300mL Shutdown straws to methanol bottles Now, place both staining straws into one of the methanol bottles and the buffer straw into the other methanol bottle. Select Next Shutdown steps1-3 complete Select next to continue. Select Next to continue. ADVIA® 2120i Autoslide Weekly Shutdown 300mL 300mL shutdown complete The Autoslide will draw methanol through the straws and into the staining wells. Leave the straws as they are until the next weekly startup. The weekly shutdown process is now complete. Startup ADVIA® 2120i Autoslide Weekly Startup Startup introduction The next part of this video will show you how to perform a weekly startup on the ADVIA 2120i Autoslide. Whenever a weekly shutdown has been performed, a weekly startup procedure must be carried out the next time the Autoslide is started. When you begin this procedure, there should be one bottle containing two staining straws and one bottle containing the buffer straw. There may be some residual methanol left in the bottles with the straws. So, before you begin this procedure, ensure you are using personal protective equipment and have proper ventilation. You will also need the buffer bottle, the two stain bottles, and two clean, empty reagent bottles. Select Weekly Startup AutoSlide Operations From the AutoSlide Operations screen, select Weekly Startup. Select Weekly Startup to continue. Weekly Startup Screen Instructions for this procedure display on the screen. This video will demonstrate these instructions for you, step-by-step. ADVIA® 2120i Autoslide Weekly Startup Startup straws to empty bottles Remove both staining straws and place them into one empty bottle together. Remove the buffer straw and place it into another empty bottle. ADVIA® 2120i Autoslide Weekly Startup Startup close reagent bottles Close the reagent bottles that formerly contained methanol with their caps. Select Next Startup steps 1-3 complete The first 3 steps of the weekly startup are complete. Select Next to continue. Select Next to continue. Startup - empty lines screen The next set of instructions are displayed on this screen. This video will demonstrate these steps. ADVIA® 2120i Autoslide Weekly Startup Stain 1 Stain 2 Startup straws to stain bottles Transfer the staining straws into their stain bottles. Ensure the correct straw goes into the correct stain bottle. ADVIA® 2120i Autoslide Weekly Startup Buffer Startup buffer straw to buffer bottle Transfer the buffer straw to the buffer bottle. Select Next Startup procedure complete Select Next to continue. Select Next to continue. Startup Complete The stains and buffer are then primed. This completes the Weekly Startup for the ADVIA 2120i Autoslide. Conclusion Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. ADVIA, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc., or its affiliates. All other trademarks and brands are the property of their respective owners. © Siemens Healthcare GmbH 2023 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com Disclaimer Effective Date: 17 APR 2023 | HOOD05162003346973 1 Shutdown 1.1 Introduction 1.6 Weekly Shutdown 1.7 shutdown methanol to bottles 1.3 Home Screen 1.4 Operations Screen 1.5 Autoslide Operations 1.2 shutdown you will need 1.8 shutdown staining straws to one bottle 1.9 shutdown buffer straw to empty bottle 1.10 shutdown status before next 1.11 Shutdown steps1-3 complete 1.12 Shutdown empty lines 1.13 Shutdown straws to methanol bottles 1.14 Shutdown steps1-3 complete 1.15 shutdown complete 2 Startup 2.1 Startup introduction 2.2 AutoSlide Operations 2.3 Weekly Startup Screen 2.4 Startup straws to empty bottles 2.5 Startup close reagent bottles 2.6 Startup steps 1-3 complete 2.8 Startup straws to stain bottles 2.7 Startup - empty lines screen 2.9 Startup buffer straw to buffer bottle 2.10 Startup procedure complete 2.11 Startup Complete 3 Conclusion 3.1 Disclaimer
- adiva
- avdia
- advai
- 2021