Siemens Healthineers Academy

4D workflow - Midventilation phase (USA)

In this video you will learn how to display the Midventilation phase.

Target group: All users
Audio: Yes
Recommended to be viewed on the following devices: All (incl. tablet and smartphone)

In this video you will learn how to display the mid ventilation phase. Please keep in mind that the user interface may differ slightly on different host systems load. The patient into the application. The 4D phases. Are loaded and contoured in the image area. After all single phases are contoured, the mid ventilation phase can be displayed. To do so, press the play button to watch the movie. This gives you information about the movement of the tumor and helps you during the treatment planning process. Right click on your lesion structure in Anatomy and Targets. The context menu opens. Select Show movement to open the Tumor curve window. In the tumor curve window you can switch between tumor trajectory and distance to mid position. In the Tumor trajectory window, you can see the movement in the different amplitudes in numbers. You can also see the phase closest to mid position in the tumor trajectory in the distance to. Mid position you will see the graph of the closest position. The tumor curve information is only visible in MMRT image suite. It cannot be exported. As soon as you are finished, close the window and continue with the internal target volume. Short ITV creation.

8/22/2016 1200 600 20 -600 0.15 0.1 0.05 0.0 0.08 0.06 0.04 0.02 0.12 10:54 4D workflow This training material is based on the medical devices syngo.via RT Image Suite VB80A. SIEMENS . MM RT Image Suite Series SP R41.6 P1B1 long pall 3.0 B30f 75% Ex Add Study SP F399.3 4:05:58 PM Series Name Structure Set 1 Anatomy & Targets UNAPPROVED Favorite Tools Structures PO Lesion Average_Various1 Patient Protocol 10cm ORGAN SL min W 1200 Topogram 0.6 T20f Findings CT Senes 10:53 AM IL syngo.via Scanner Al-Rad Companion Syngo Carbon View&GO Space Please keep in mind that the user interface may differ slightly from what is shown in this video. The actual usage of the tool may differ slightly on the different host systems, for example, on syngo.via, Syngo Carbon Space, syngo.via View&GO, Al-Rad Companion or on the scanner. However, the intended purpose of the tool is the same. The tool functionality defined in this video is applicable to any of the Siemens Healthineers products in which you find this tool. Serles Name Nam P1B1 long pall 3.0 P1B1 long pall 3.0 B Patient Beam W 120 Placement L min Healthineers SL 8 IMA n.a Rename Change Type Erase Contours Delete Duplicate Merge Lock Show as defined in Propagate to Show Movement Create ITV Overwrite HU IMA n.a IMA n. a Show as defined In Tumor Curve Structure/POI : Lesion Anatomy & Head-Feet Amplitude : 0.20 cm Struct Left-Right Amplitude : 0.07 cn Anterior-Posterior Amplitude : 0.13 cm Phase Closest to Midposition : 50% In O Tumor Trajectory O Distance to Midposition Distance (cm) -75% Ex -50% Ex -25% Ex 0% In 25% In 50% In 75% In 100% In Phase Only use 4D data that is binned equidistant in time to identify midventilation phase! OK Lung Marking Placen Create Placen Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Unrestricted | Published by Siemens Healthineers AG | C Siemens Healthineers AG, 2024 Siemens Healthineers HQ | Siemens Healthineers AG Siemensstr. 3 91301 Forchheim Germany Phone: +49 9191 18-0 siemens-healthineers.com SIEMENS

  • syngovia
  • syngo via