ACUSON Sequoia™ 3.5 VB30 UDFF Quick Card

This document will help the user understand the UDFF features using the ACUSON Sequoia™ ultrasound system.

Quick Card Ultrasound Derived Fat Fraction (UDFF) ACUSON Sequoia Ultrasound System 3.5 (VB30) siemens-healthineers.com/sequoia Using the Ultrasound Derived Fat Fraction (UDFF) technology to quantify fat contained within a patient’s liver and display it as a percentage (%) Step 1 DAX Abdomen • Select a compatible transducer and the Abdomen exam preset Step 2 • Press VT (Virtual Touch) located on VT the Control Panel SIEMENS Healthineers . Step 3 UDFF Step 7 • Select the UDFF key from the Touch To enter the measurement Screen – the pSWE ROI will enlarge into the report: to UDFF size once activated • Press Image to store the image Liver Site 1 is active as the default Image • or measurement label • Press the right or left Set key • If desired, select an alternate label Note: If No Label is selected, measurements will appear next to the image, but will not Step 8 be sent to the report or added to the overall • statistics. Unfreeze, repeat steps 5–8 to acquire additional measurements Freeze Note: If selected from the Touch Screen, the Auto Point Shear Wave (Auto pSWE) Note: Five measurements at the same technology can be used simultaneously site are recommended, however, with UDFF.1 Measurement values for both more can be performed based on the technologies will be displayed on the screen. individual site protocol or study specifics. Auto pSWE is compatible with the Deep Abdominal Transducer (DAX) and 9C2 transducer on the Abdomen exam preset. Step 9 Report • Select Report on the left side of the Touch Screen Step 4 • View, delete, store, print, or transfer • Roll the Trackball to position the ROI the UDFF measurements (region of interest) at least 1.5–2 cm below the liver capsule Liver Site 1 UDFF Depth % cm • Ensure the “+” marker on the sample 5.7 line is parallel with the liver capsule 10 5.5 5.5 8 5.5 5.5 Mean 8.8 Std Dev 1.6 Step 5 Median 8.0 Update IQR 3.0 IQR/Median 0.4 • Instruct the patient to suspend Overall Statistics respiration; then press the Mean 8.8 % Std Dev 1.6 % Median 8.0 % IQR 3.0 % IQR/Median 0.4 Update key on the Control Panel to begin the acquisition Step 6 Liver Site 1 UDFF=6 % When the acquisition is complete, Depth=4.3 cm • the system automatically freezes, emits one audible “beep”, and displays the UDFF measurement and ROI depth next to the image 1 UDFF is compatible with the Deep Abdominal Transducer (DAX), 5C1, and 9C2 transducer on the Abdomen exam preset. If UDFF is used with Auto pSWE, the transducer cooling time will be increased. 2 siemens-healthineers.com/ultrasound DAX Liver Site 5 Abdomen UDFF=10 % TIB:0.85 Depth=5.5 cm TIC:2.44 TIS:0.85 MI:1.38 Ultrasound Derived 20fps 95% 2D H Low Fat Fraction -4dB/DR60 c=1540 PSWE Liver Application Best Practice Techniques 16cm Cooling 6 Fig. 1: Optimal technique Fasting for at least four hours In the non-fasting state, liver values may be have falsely increased. Position the patient supine or in a slight Optimal positioning improves intercostal access and clearly (30°) left lateral decubitus position with visualizes an artifact-free area of the liver. the right arm raised above the head Ensure the transducer is perpendicular Inaccurate or invalid measurements can result if the transducer is to the skin surface and use ample gel not perpendicular to the skin line and/or there is a loss of contact between the transducer and the skin. Take measurements in the right lobe of Placing the ROI in an artifact-free area devoid of vessels, large ducts, the liver, at least 1.5–2 cm below the and/or fluid-filled structures, such as cysts, is recommended to liver capsule (Fig. 1) using an intercostal obtain reproducible results. scanning approach Align “+” marker (arrow) on the sample Non-parallel alignment can result in inaccurate measurements – tilt line parallel to the liver capsule (Fig. 1) or rock the transducer to achieve proper alignment. Perform the acquisition during Instruct the patient to breathe normally and then to momentarily suspended respiration; the patient may stop breathing during the acquisition. When the acquisition is resume normal breathing after an complete, the system freezes and emits one audible “beep”; the audible “beep” is heard patient can then resume normal breathing. Obtain five measurements at same site Recommended number of measurements to obtain reliable results. siemens-healthineers.com/ultrasound 3 For the proper use of the software or hardware, please always use At Siemens Healthineers, we pioneer breakthroughs in healthcare. the Operator Manual or Instructions for Use (hereinafter collectively For everyone. Everywhere. Sustainably. As a leader in medical “Operator Manual”) issued by Siemens Healthineers. This material is technology, we want to advance a world in which breakthroughs to be used as training material only and shall by no means substitute in healthcare create new possibilities with a minimal impact on the Operator Manual. Any material used in this training will not be our planet. By consistently bringing innovations to the market, updated on a regular basis and does not necessarily reflect the latest we enable healthcare professionals to innovate personalized care, version of the software and hardware available at the time of the achieve operational excellence, and transform the system of care. training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and Our portfolio, spanning in vitro and in vivo diagnostics to image- cautions. guided therapy and cancer care, is crucial for clinical decision- making and treatment pathways. With the unique combination of Note: Some functions shown in this material are optional and might our strengths in patient twinning2, precision therapy, as well as not be part of your system. digital, data, and artificial intelligence (AI), we are well positioned to take on the greatest challenges in healthcare. We will continue Certain products, product related claims or functionalities described to build on these strengths to help overcome the world’s most in the material (hereinafter collectively “Functionality”) may not threatening diseases, enable efficient operations, and expand (yet) be commercially available in your country. Due to regulatory access to care. requirements, the future availability of said functionalities in We are a team of more than 71,000 Healthineers in over 70 countries any specific country is not guaranteed. Please contact your local passionately pushing the boundaries of what is possible in Siemens Healthineers sales representative for the most current healthcare to help improve the lives of people around the world. information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. ACUSON Sequoia is a trademark of Siemens Medical Solutions USA, Inc. Siemens Healthineers Ultrasound owns the rights to all images. 2 Personalization of diagnosis, therapy selection and monitoring, after care and managing health. Siemens Healthineers Headquarters Manufacturer Siemens Healthineers AG Siemens Medical Solutions USA, Inc. Siemensstr. 3 Ultrasound 91301 Forchheim, Germany 22010 S.E. 51st Street Phone: +49 9191 18-0 Issaquah, WA 98029, USA siemens-healthineers.com Phone: 1-888-826-9702 siemens-healthineers.com/ultrasound Published by Siemens Medical Solutions USA, Inc. · QR700011295 · 15698 1124 online only · ©Siemens Medical Solutions USA, Inc., 2024

  • UDFF
  • Liver
  • Elastography
  • steatosis
  • fatty liver