Siemens Healthineers Academy

ACUSON Sequoia 3.5 VB30 Modality Compare Presentation

This document explains the Modality Compare feature using the ACUSON Sequoia ultrasound system.

SIEMENS Healthineers SIEMENS Healthineers ... ACUSON Sequoia Ultrasound System Modality Compare Release 3.5 (VB30) 1 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 1 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Define Modality Compare • Explain reference image options PODLES • Review Modality Compare clinical solutions • Outline Importing studies for comparison • Demonstrate Modality Compare initiation 2 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 2 SIEMENS Healthineers Modality Compare SIEMENS .... Healthineers ... Overview • Import and view historic patient studies along Transducer ? side real-time ultrasound D=45.8 mm Needle • Available for all ultrasound exam types and all transducers • Real-time imaging or review 16cm 3 Unrestricted © Siemens Healthineers 2024 Speaker Notes: Modality Compare is an ultrasound tool which allows the user to import and view historic patient reference data side-by-side with the current real-time or frozen ultrasound image. It is available for all ultrasound exam types and all transducers. Notes No. 3 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Define Modality Compare • Explain reference image options • Review Modality Compare clinical solutions • Outline Importing studies for comparison • Demonstrate Modality Compare initiation 4 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 4 SIEMENS Healthineers Modality Compare SIEMENS .... Healthineers ... Reference image options 18L6 The following modalities are compatible with Breast TIB:0.19 Modality Compare: TIC:0.29 TIS:0.19 MI:0.47 • Mammography 50fps • CT 2D High -2dB/DR65 • MRI • Ultrasound (static and clips) • ABVS (Automated Breast Volume Scanner) 3.5cm 5 Unrestricted © Siemens Healthineers 2024 Speaker Notes: The following modalities are compatible with Modality Compare: • Mammography • Computed Tomography (CT) • Magnetic Resonance Imaging (MRI) • Ultrasound (imports static and ultrasound clips) • Automated Breast Volume Scanner (ABVS) (will appear as ultrasound clips only) Notes No. 5 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Define Modality Compare • Explain reference image options • Review Modality Compare clinical solutions • Outline Importing studies for comparison • Demonstrate Modality Compare initiation 6 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 6 SIEMENS Healthineers Modality Compare SIEMENS .... Healthineers ... Clinical solutions 14L5 • Serial scan comparisons MSK TIB:0.35 TIC:0.81 TIS 0.35 • Biopsy planning and guidance MI:0.79 50fps 95% Mammographic correlation 2D • H High 2dB/DR60 • Isoechoic lesion detectability • Multiple lesion discrimination 4.5cm 7 Unrestricted © Siemens Healthineers 2024 Speaker Notes: Modality Compare is a multi-modality diagnostic aid that can be used during an interventional procedure or outside of the procedure setting. It can be used for: • Serial scan comparison (e.g. multinodular thyroid exams, changes in lesion size after treatment) • Interventional biopsy planning and guidance • Mammographic correlation • Targeting difficult to visualize lesions • Evaluation of multiple lesions with higher diagnostic confidence Modality Compare is compatible with all transducers and is independent of modality vendor. This allows the user to load any compatible reference image, from any vendor, onto the ACUSON Sequoia ultrasound system. Notes No. 7 SIEMENS Healthineers Modality Compare SIEMENS. Healthineers ... Benefits Increase diagnostic confidence during exams by allowing technologist or physician precision when correlating indeterminate pathology, isoechoic lesions or during biopsies Clinical Value Improve procedural efficiency by potentially eliminating excessive correlation time during biopsies or serial exams Operational Value $ Potentially avoid additional cost by eliminating the need for additional viewing equipment in the procedure rooms Financial Value 8 Unrestricted © Siemens Healthineers 2024 Speaker Notes: The key clinical, operational and financial benefits for Modality Compare imaging are displayed. The Modality Compare tool provided on the ACUSON Sequoia ultrasound system has significantly changed the workflow experience by bringing practicality to this technology: • May increase diagnostic confidence during exams by allowing technologist or physician more precision when correlating indeterminate pathology, isoechoic lesions or during biopsies • Potentially improve procedural efficiency by eliminating excessive correlation time during biopsies or serial exams • Potentially avoid additional cost by eliminating the need for additional viewing equipment in the procedure rooms Notes No. 8 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Define Modality Compare • Explain reference image options PODLES • Review Modality Compare clinical solutions • Outline Importing studies for comparison • Demonstrate Modality Compare initiation 9 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Image: HOOD05162003330011 Notes No. 9 SIEMENS Healthineers Modality Compare SIEMENS . Healthineers ... Import studies from USB Insert USB drive or CD/DVD Import from off-line 1 Patient Browser 1. Enter the Patient Browser Source Media 2 Source Media Path 2. Select the Source Media (USB or CD/DVD) Local Database 4 ¿ CTABML2012-4-5-12-35-45-484.CT. . 0003.0028.2015.11.16.13.09 1. CTABML2012-4-5-12-35-45-484.CT. . 0003.0029.2015.11.16.13.09 3. Select Import from off-line Available: 879.0 GB / 894.3 GB 22 14 CTABML2012-4-5-12-35-45-484.CT. . 0003.0030.2015.11.16.13.09 14 CTABML2012-4-5-12-35-45-484.CT. . 0003.0031.2015.11.16.13.05 4. Select the studies you would 3 mport from off-line LE CTABML2012-4-5-12-35-45-484.CT. . 0003.0032.2015.11.16.13.09 22 15 CTABML2012-4-5-12-35-45-484.CT. 0004.0238.2015.11.16.13.05 like import by selecting the 14 CTABML2012-4-5-12-35-45-484.CT. . 0004.0239.2015.11.16.13.05 LE CTABML2012-4-5-12-35-45-484.CT. . 0004.0240.2015.11.16.13.09 first study and then pressing Period 14 CTABML2012-4-5-12-35-45-484.CT._.0004.0241.2015.11.16.13.05 Shift on the keyboard and 14 CTABML2012-4-5-12-35-45-484.CT. . 0004.0242.2015.11.16.13.09 selecting the last study [] Custom Range Show All 5 Import Close 5. Select Import 10 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To import a study for use with Modality Compare from a Universal Serial Bus (USB): • Insert USB drive or CD/DVD 1. Enter the Patient Browser 2. Select the Source Media (USB or CD/DVD) 3. Select Import from off-line 4. Select the studies you would like import by selecting the first study and then pressing Shift on the keyboard and selecting the last study 5. Select Import Notes No. 10 SIEMENS Healthineers Modality Compare SIEMENS . Healthineers ... Query/Retrieve PACS 1. Enter the Patient Browser Patient Browser 1 2. Select Query/Retrieve Source Media - Searc Local Database Patient Name Accession No. Operator 3. Enter the search parameters Import from off-line Patient In 3 Date of Birt Gender Clear Search 4. Select the desired study to highlight Period Custom Range Study List Search within results Show All Patient Name Select Import Patient ID Exam Date & Time Size (MI) 5. V TEST CV REPORT 24.02.08-19:53:3 ... 218/2024 07:53:33 PM O V CV REPORT 24.02.08-19:42:0 ... Cardiac 218/2024 07:42:07 PM 12 46 ¥ CV REPORT 24.02.08-19:40-0 ... CanSac 218/2024 07:40:05 PM O 11 TESTICLE FEB 8 RADIX 3.0 24.02.08-11:43:2 ... 2/8/2024 11:43:27 AM 21 6 86 RP 24.02.07-17:06:5 ... 2/7/2024 05:06:56 PM 19 15 136 GR 24.02.07-14:03:5 ... 2/7/2024 02:03:56 PM 11:17 168 V DB DAX 24.02.07-11:26:0 ... Abdomen 2/7/2024 11:26:05 AM ₹28 16 166 V DCDAX 4 24.02.07-09:21:2 ... Abdomen 2/7/2024 09:21:21 AM 35:47 320 CV TEST1, DAY3 24.02.01-11:33:3 ... 2/1/2024 11:33:39 AM 3 39 11 TEST4, DAY2 24.01.31-13:51:3 ... 1/31/2024 01:51:39 PM V TESTI, DAY2 24.01.31-09:14:0 ... 1/31/2024 09:14:04 AM O E TEST LEE, DAY! 24.01.30-12:48:3 ... 1/30/2024 12:48:34 PM 14 6 66 X TEST3, DAY1 24.01.30-11:24:0 ... 1/30/2024 11:24:09 AM O V TEST2, DAYT 24.01.30-10:24:0 ... 1/30/2024 10-24:09 AM 3 29 2 veryRetrieve V TESTI, DAY1 24.01.30-09:48:1 ... 1/30/2024 09-18:14 AM 5 17 5 Import Job Status: 11 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To import (Query/Retrieve) from Picture Archive and Communication System (PACS): 1. Enter the Patient Browser 2. Select Query/Retrieve at the bottom left of the monitor or from the Touch Screen 3. Enter the search parameters 4. Select the desired study to highlight and import 5. Select Import Notes No. 11 SIEMENS Healthineers Modality Compare Import studies Patient Browser - Search Local Datatuas Patient Name cession No Operator Import from off-line Patient ID date of birth Geruser Dear Search Perlod []Custom Range Study List Search within results Show All e & Time Sue (MII) DC DAX 24.02.07-09-21:2 ... Abdomen 2/7/2024 09:21:21 AM 35 47 320 OV TEST1. DAY3 24.02.01-11:33:3. 2/1/2024 11:33:39 AM 3 0:11 TEST4, DAY2 24.01.31-13:51:3 ... 1/31/2024 01:51:39 PM 0 TEST1, DAY2 24.01.31-09:14:0 ... 1/31/2024 09:14:04 AM O Y TEST LEE, DAY1 24.01.30-12:48:3 .. 1/30/2024 12:48:34 PM 14 O X TEST3, DAYS 24.01.30-11:24:0 ... 1/30/2024-11:24:09 AM O Y TEST2, DAY1 24.01.30-10:24:0 ... 1/30/2024 10:24:09 AM TESTI, DAY1 24.01.30-09:48:1 ... 1.80/2024 09-18:14 AM 5 OV TEST 24.01.29-15:12:2 ... 1/29/2024 03:12:23 PM D DV Unknown 24.01.17-10:45:4 .. 1/17/2024 10:45:44 AM 23 6 ACUSON Sequela 2 0 VAMO CTABML2012-4-5-12:35-45-48 Anonymous 16/2012 08-52-28 AM 401 0 Modality: CT- Modality: CT Description 216/2012 08.55:48 AM Query Retrieve Images: 242 206/2012 08:55:53 AM Total: 20 Selected: 1 (284.0 MB) Delete Job Status Load to Review New Study 07403 12 Unrestricted © Siemens Healthineers 2024 Speaker Notes: After import is complete (from either USB or Query/Retrieve), the study will appear in the local database in the patient browser and will be available to load to review only. Select the patient’s current study from the worklist or manually register the patient to begin the exam. Now that the reference images have been loaded, and the patient's current study is active. The Modality compare workflow will be covered in the next section. Notes No. 12 SIEMENS Healthineers Objectives SIEMENS. Healthineers ... • Define Modality Compare • Explain reference image options PODLES • Review Modality Compare clinical solutions • Outline Importing studies for comparison • Demonstrate Modality Compare initiation 13 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Image: HOOD05162003330011 Notes No. 13 SIEMENS Healthineers Modality Compare SIEMENS . Healthineers ... Activate 1. Select Workflow 1 Workflow erence Images Studies 2. Select Modality [0] 2/6/2012 08:52 AM Study Description Series Compare (the 1 2/6/2012 08 52 AM [0] 2/6/2012 08.52 AM Fusion Panoramic Protocols system will display a 3 list of studies for the registered patient Modality Compare Physio CDx Images Select All Select None stored in the local 2 database) 3. Select the required 4 study 4. Select the reference images 23 5. Select OK 265 27 -0 5 OK Cancel 14 Unrestricted © Siemens Healthineers 2024 Speaker Notes: To activate Modality Compare: 1. Select Workflow 2. Select Modality Compare (the system will display a list of studies for the registered patient stored in the local database) 3. Select the required study 4. Select the reference images 5. Select OK Notes No. 14 SIEMENS Healthineers Modality Compare SIEMENS .. Healthineers ... Activate 18L6 5C1 Breast Abdomen TIB:0.19 TIB:0.60 TIC:0.29 TIC:2.84 TIS:0.19 MI:0.47 MI:1.12 50fps 21fps 95% 98% 2D 2D High H High -2dB/DR65 1dB/DR60 13cm 3.5cm 15 Unrestricted © Siemens Healthineers 2024 Speaker Notes: The reference image will appear to the left of the real-time ultrasound image. Notes No. 15 SIEMENS Healthineers Modality Compare Activate 1. Image DAX Abdomen 5C1 2A 10L4 1816 Workflow 2. Zoom Patient 2D Modality Compare 5 maging 3. Pan Select Images Remove Image Exit Review 4. Window Report Pan 3 Window 410 4 Level 45 4 End Exam 5. Exit Apply to All Reset to Default 1 2 Image Zoom 100% 16 Unrestricted © Siemens Healthineers 2024 Speaker Notes: The Modality Compare Touch Screen layout appears above. 1. Rotate the Image soft key to change the displayed reference image 2. Rotate the Zoom soft key to magnify the reference image 3. Slide your finger across the Pan area to reposition the reference image 4. Slide your finger across the Window/Level area to change the brightness/contrast the reference image 5. Select Exit to close Modality Compare Notes No. 16 SIEMENS Healthineers Trademarks and disclaimers SIEMENS. Healthineers ... ACUSON Sequoia is a registered trademarks of Siemens Medical Solutions USA, Inc. PODLES 17 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 17 SIEMENS Healthineers Thank you for your enthusiasm! SIEMENS. Healthineers ... Questions? 18 Unrestricted © Siemens Healthineers 2024 Speaker Notes: No speaker notes. Notes No. 18

  • Modality Compare